From dda26c32c8d04e0e3cad6af61840d39909854019 Mon Sep 17 00:00:00 2001 From: =?utf8?q?J=C3=A9r=C3=B4me=20Benoit?= Date: Sat, 27 May 2023 14:30:16 +0200 Subject: [PATCH] docs: refine README.md MIME-Version: 1.0 Content-Type: text/plain; charset=utf8 Content-Transfer-Encoding: 8bit Signed-off-by: Jérôme Benoit --- README.md | 114 +++++++++++++++++++++++++++--------------------------- 1 file changed, 57 insertions(+), 57 deletions(-) diff --git a/README.md b/README.md index 46c8038f..27b24d3c 100644 --- a/README.md +++ b/README.md @@ -131,63 +131,63 @@ But the modifications to test have to be done to the files in the build target d **src/assets/station-templates/\.json**: -| Key | Value(s) | Default Value | Value type | Description | -| ---------------------------------------------------- | ------------- | ----------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | -| supervisionUrls | | [] | string \| string[] | string or array of connection URIs to OCPP-J servers | -| supervisionUser | | undefined | string | basic HTTP authentication user to OCPP-J server | -| supervisionPassword | | undefined | string | basic HTTP authentication password to OCPP-J server | -| supervisionUrlOcppConfiguration | true/false | false | boolean | allow supervision URL configuration via a vendor OCPP parameter key | -| supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL | -| ocppVersion | 1.6/2.0/2.0.1 | 1.6 | string | OCPP version | -| ocppProtocol | json | json | string | OCPP protocol | -| ocppStrictCompliance | true/false | false | boolean | strict adherence to the OCPP version and protocol specifications | -| ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) | -| stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) | -| automaticTransactionGeneratorPersistentConfiguration | true/false | true | boolean | enable persistent automatic transaction generator storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) | -| wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection | -| idTagsFile | | undefined | string | RFID tags list file relative to src/assets path | -| baseName | | undefined | string | base name to build charging stations id | -| nameSuffix | | undefined | string | name suffix to build charging stations id | -| fixedName | true/false | false | boolean | use the baseName as the charging stations unique name | -| chargePointModel | | undefined | string | charging stations model | -| chargePointVendor | | undefined | string | charging stations vendor | -| chargePointSerialNumberPrefix | | undefined | string | charge point serial number prefix | -| chargeBoxSerialNumberPrefix | | undefined | string | charge box serial number prefix (deprecated in OCPP 1.6) | -| firmwareVersionPattern | | Semantic versionning regular expression: https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string | string | charging stations firmware version pattern | -| firmwareVersion | | undefined | string | charging stations firmware version | -| power | | | float \| float[] | charging stations maximum power value(s) | -| powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors | -| powerUnit | W/kW | W | string | charging stations power unit | -| currentOutType | AC/DC | AC | string | charging stations current out type | -| voltageOut | | AC:230/DC:400 | integer | charging stations voltage out | -| numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) | -| numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) | -| useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template | -| randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template | -| resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset | -| autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose | -| autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server | -| reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server | -| registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries | -| amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC | -| amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit | -| enableStatistics | true/false | false | boolean | enable charging stations statistics | -| mustAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled | -| payloadSchemaValidation | true/false | true | boolean | validate OCPP commands PDU against [OCA](https://www.openchargealliance.org/) JSON schemas | -| beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues | -| outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) | -| meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis | -| transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction | -| mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations | -| phaseLineToLineVoltageMeterValues | true/false | false | boolean | include charging stations line to line voltage MeterValues on three phased charging stations | -| customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues | -| firmwareUpgrade | | {
"versionUpgrade": {
"step": 1
},
"reset": true
} | {
versionUpgrade: {
patternGroup: number;
step: number;
};
reset: boolean;
failureStatus: 'DownloadFailed' \| 'InstallationFailed';
} | Configuration section for simulating firmware upgrade support. | -| commandsSupport | | {
"incomingCommands": {},
"outgoingCommands": {}
} | {
incomingCommands: Record;
outgoingCommands?: Record;
} | Configuration section for OCPP commands support. Empty section or subsections means all implemented OCPP commands are supported | -| messageTriggerSupport | | {} | Record | Configuration section for OCPP commands trigger support. Empty section means all implemented OCPP trigger commands are supported | -| Configuration | | | ChargingStationOcppConfiguration | charging stations OCPP parameters configuration section | -| AutomaticTransactionGenerator | | | AutomaticTransactionGeneratorConfiguration | charging stations ATG configuration section | -| Connectors | | | Record | charging stations connectors configuration section | -| Evses | | | Record | charging stations EVSEs configuration section | +| Key | Value(s) | Default Value | Value type | Description | +| ---------------------------------------------------- | ------------- | ----------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | +| supervisionUrls | | [] | string \| string[] | string or array of connection URIs to OCPP-J servers | +| supervisionUser | | undefined | string | basic HTTP authentication user to OCPP-J server | +| supervisionPassword | | undefined | string | basic HTTP authentication password to OCPP-J server | +| supervisionUrlOcppConfiguration | true/false | false | boolean | allow supervision URL configuration via a vendor OCPP parameter key | +| supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL | +| ocppVersion | 1.6/2.0/2.0.1 | 1.6 | string | OCPP version | +| ocppProtocol | json | json | string | OCPP protocol | +| ocppStrictCompliance | true/false | false | boolean | strict adherence to the OCPP version and protocol specifications | +| ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) | +| stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) | +| automaticTransactionGeneratorPersistentConfiguration | true/false | true | boolean | enable persistent automatic transaction generator configuration storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) | +| wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection | +| idTagsFile | | undefined | string | RFID tags list file relative to src/assets path | +| baseName | | undefined | string | base name to build charging stations id | +| nameSuffix | | undefined | string | name suffix to build charging stations id | +| fixedName | true/false | false | boolean | use the baseName as the charging stations unique name | +| chargePointModel | | undefined | string | charging stations model | +| chargePointVendor | | undefined | string | charging stations vendor | +| chargePointSerialNumberPrefix | | undefined | string | charge point serial number prefix | +| chargeBoxSerialNumberPrefix | | undefined | string | charge box serial number prefix (deprecated in OCPP 1.6) | +| firmwareVersionPattern | | Semantic versionning regular expression: https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string | string | charging stations firmware version pattern | +| firmwareVersion | | undefined | string | charging stations firmware version | +| power | | | float \| float[] | charging stations maximum power value(s) | +| powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors | +| powerUnit | W/kW | W | string | charging stations power unit | +| currentOutType | AC/DC | AC | string | charging stations current out type | +| voltageOut | | AC:230/DC:400 | integer | charging stations voltage out | +| numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) | +| numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) | +| useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template | +| randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template | +| resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset | +| autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose | +| autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server | +| reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server | +| registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries | +| amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC | +| amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit | +| enableStatistics | true/false | false | boolean | enable charging stations statistics | +| mustAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled | +| payloadSchemaValidation | true/false | true | boolean | validate OCPP commands PDU against [OCA](https://www.openchargealliance.org/) JSON schemas | +| beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues | +| outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) | +| meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis | +| transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction | +| mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations | +| phaseLineToLineVoltageMeterValues | true/false | false | boolean | include charging stations line to line voltage MeterValues on three phased charging stations | +| customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues | +| firmwareUpgrade | | {
"versionUpgrade": {
"step": 1
},
"reset": true
} | {
versionUpgrade: {
patternGroup: number;
step: number;
};
reset: boolean;
failureStatus: 'DownloadFailed' \| 'InstallationFailed';
} | Configuration section for simulating firmware upgrade support. | +| commandsSupport | | {
"incomingCommands": {},
"outgoingCommands": {}
} | {
incomingCommands: Record;
outgoingCommands?: Record;
} | Configuration section for OCPP commands support. Empty section or subsections means all implemented OCPP commands are supported | +| messageTriggerSupport | | {} | Record | Configuration section for OCPP commands trigger support. Empty section means all implemented OCPP trigger commands are supported | +| Configuration | | | ChargingStationOcppConfiguration | charging stations OCPP parameters configuration section | +| AutomaticTransactionGenerator | | | AutomaticTransactionGeneratorConfiguration | charging stations ATG configuration section | +| Connectors | | | Record | charging stations connectors configuration section | +| Evses | | | Record | charging stations EVSEs configuration section | #### Configuration section syntax example -- 2.34.1