Merge branch 'release'
[deb_libcec.git] / ChangeLog
CommitLineData
b3efc8f2
LOK
1libcec (0.8-2) unstable; urgency=low
2
3 * added 'libboost-dev' to build deps
4
5 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 01 Nov 2011 23:31:00 +0100
6
971d0e9e
LOK
7libcec (0.8-1) unstable; urgency=low
8
9 * interface changes:
10 * added GetDevicePowerStatus()/cec_get_device_power_status()
11 * added GetDeviceVendorId()/cec_get_device_vendor_id()
12 * added GetDeviceMenuLanguage()/cec_get_device_menu_language()
13 * added GetDeviceCecVersion()/cec_get_device_cec_version()
14 * added SwitchMonitoring()/cec_switch_monitoring() to the interface. when
b3efc8f2
LOK
15 monitoring is enabled, the device will only log the data it received,
16 but will not respond to any message
971d0e9e 17 * removed timeout parameter in Transmit() and included the ack timeout in
b3efc8f2 18 the cec_command struct
971d0e9e
LOK
19 * made the vendor id -> vendor name translation available
20 * made CEC_LOG levels powers of 2
21 * introduced CEC_LOG_TRAFFIC log level
22 * fixed:
23 * set the correct ackmask on startup
24 * wait for ack while keeping a lock
25 * wait for the processor thread to start before continueing on startup
26 * wait for messages to be transmitted before continueing in
b3efc8f2 27 CCECProcessor::Transmit()
971d0e9e
LOK
28 * only set the logical address once when it has changed
29 * correct source for broadcast messages
30 * win32: create Release type installer
31 * changed:
32 * make all reads and write in CAdapterCommunication go through buffers.
33 * poll for a vendor ID of connected devices and switch to a non-standard
b3efc8f2 34 CEC implementation if needed.
971d0e9e
LOK
35 * added vendor detection of Samsung and LG devices
36 * handle samsung remote command 'return'
37 * cec-client:
38 * added -la and --logical-address to the command line params
39 * added -d and --log-level params to cec-client
40 * added -sf and --short-log-file, which only log the actual messages, not
b3efc8f2 41 the level and timestamp
971d0e9e
LOK
42 * added -f and --log-file parameters to cec-client
43 * added option to change the log level to cec-client
44
b3efc8f2 45 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 01 Nov 2011 22:58:00 +0100
971d0e9e 46
8f084f00
LOK
47libcec (0.7-1) unstable; urgency=low
48
49 * send a keypress with 0 duration when a key is pressed and with a duration
50 set when it's released
51 * added SetOSDString() to the interface (not supported by all tvs)
52 * fixed: 'routing change' is a broadcast message. log routing changes, but
53 don't send a 'set active view' message, so the active input won't be
54 changed
55 * log keypresses in the debug log
56 * added 'pa' command to cec-client, to change the physical address
57 * added SetPhysicalAddress()/cec_set_physical_address() to the interface, so
58 the HDMI port number to use can be changed
59 * fixed: put the message processing code from WaitForAck() in ParseMessage().
60 fixes missing incoming message logging of non-data messages when not
61 waiting for an ACK
62 * added 'txn' command to cec-client. same as 'tx', but doesn't wait for ACK
63 before returning
64 * fixed: set initiator and destination first in cec_command::push_back().
65 fixes 'tx' command in cec-client
66 * fixed: keep trying to connect while iTimeout isn't reached (default 10
67 seconds). fixes exit with a 'permission denied' error when the device isn't
68 ready yet. remove CEC_SETTLE_DOWN_TIME
69 * fixed: don't call SetActiveView() when reporting the power status. fixes
70 loop which causes some TVs to report failed connections
71 * fixed: eom was not being parsed when receiving MSGCODE_FRAME_DATA. fixed.
72 * fixed: add the device type as parameter when sending the physical address.
73 thanks bobo1on1
74 * fixed: typo in libcec.pc.in
75 * added optional strLib parameter to LoadLibCec(), so the location of the
76 shared library can be specified
77 * only link cec-client against ld. use AC_SEARCH_LIBS instead of AC_CHECK_LIB
78 * use int instead of bool on the public C interface and remove stdbool.h include
79 * renamed: CECExports.h => cec.h, CECExportsC.h => cecc.h, CECLoader.h =>
80 cecloader.h, CECTypes.h => cectypes.h
81 * updated debian package. split up libcec and libcec-dev
82 * fixed: changed to use dlopen instead of static linkage. shuffled headers a
83 bit. bumped interface to version 7
84 * removed 'rt' from libraries. it's not needed (anymore)
85 * fixed: reset the active view after a routing change. issue #1
86 * fixed: changed attached license to be GPLv2 instead of GPLv3 this was an
87 error as libCEC is licensed GPLv2 not GPLv3 thanks @garbear
88 * added contributors link
89
90 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 14 Oct 2011 17:34:00 +0200
91
11d0a2d6
LOK
92libcec (0.6-1) unstable; urgency=low
93
94 * bumped interface version to 6
95 * fixed packet output (reporting the OSD name correctly now)
96 * refactored packet structs: split up in cec commands and adapter messages
97 * fixed i/o timings
98 * added Darwin support (thanks Davilla!)
99 * fixed WaitForAck()
100 * fixed possible deadlock when starting a new thread
101 * implemented vendor id and device class parsing. full detection will follow
102 * added "on" and "standby" commands to the test client
103 * retransmit packets if needed
104 * fix GetTimeMs() on linux
105 * added timestamp to log messages
106
107 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Sun, 09 Oct 2011 15:15:00 +0200
108
9519c249 109libcec (0.5-1) unstable; urgency=low
25701fa6
LOK
110
111 * bumped interface version to 5
112 * don't pass std::string and std::vector accross the interface
113 * fixed heap corruption crashes on windows
114 * fixed some memory leaks
115 * reset all structs to default values before doing with them
116
11d0a2d6 117 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 07 Oct 2011 22:00:00 +0200
25701fa6 118
262f3b05
LOK
119libcec (0.4-3) unstable; urgency=low
120
121 * fixed reconnect
122 * fixed some threading related bugs
123 * fixed deadlock on exit
124 * fixed wrongly reported physical address
125
126 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Thu, 06 Oct 2011 00:19:00 +0200
127
4463fb80
LOK
128libcec (0.4-2) unstable; urgency=low
129
130 * fixed int parameter sizes and some signed/unsigned warnings
131 * check whether m_port isn't NULL in ReadFromDevice
132 * stop the processor thread and delete the CSerialPort instance on exit
133 * added mutex in CSerialPort
134 * fix segfault on exit
135 * renamed libPlatform -> platform.
136 * stuck everything from libCEC in the CEC namespace to avoid namespace
137 polution
138
139 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 04 Oct 2011 23:45:00 +0200
140
88c5a743
LOK
141libcec (0.4-1) unstable; urgency=low
142
143 * bumped interface version to 4
144 * timeout parameter removed from Close()/cec_close(). return type changed to
145 void
146 * added cec_destroy() method
147 * removed timeout parameter from Transmit()
148 * change the default argument of PowerOnDevices() to CECDEVICE_TV
149 * removed PowerOffDevices(). use StandbyDevices() instead
150 * removed obsolete methods from the interface
151 * fixed bug: pthread_cond_wait was called without the mutex locked
152 * fixed possible deadlock: don't send messages and wait for an ack with the
153 mutex locked in CCECParser
154 * created a separate reader thread and fixed the 'lock timeout' bug
155 * testclient: use CECDEVICE_TV instead of the default argument
156 (CECDEVICE_BROADCAST) for PowerOnDevices() and PowerOffDevices()
157
158 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Tue, 04 Oct 2011 00:48:00 +0200
159
a9bb5b56
LOK
160libcec (0.3-1) unstable; urgency=low
161
162 * added device detection support for Windows
163
164 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Sun, 02 Oct 2011 12:09:33 +0200
165
166libcec (0.2-1) unstable; urgency=low
167
168 * added a Close() method to the interface
169 * Added CEC command that were received by the adapter in a buffer that can be
170 read by a client with GetNextCommand()/cec_get_next_command(). added a
171 'help' command to the test client, that displays all available commands
172 * Fixed setting the ackmask. deprecated SetAckMask()/cec_set_ack_mask(). use
173 SetLogicalAddress()/cec_set_logical_address() instead. add 'la' command to
174 the testclient to set the logical address of the cec adapter
175 * Added optional logical and physical address parameters to
176 LoadLibCec()/cec_init() on the interface. fixed wrongly placed namespace
177 close tag in CECExports.h. updated interface documentation. bumped
178 interface version to 2.
179 * fixed hardcoded ackmask in SetAckMast(). set a shorter display name in the
180 test client. the previous one was too long and being rejected
181
182 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Fri, 28 Sep 2011 01:33:00 +0200
183
abbca718
LOK
184libcec (0.1-1) unstable; urgency=low
185
186 * Initial release v0.1
187
a9bb5b56 188 -- Pulse-Eight Packaging <packaging@pulse-eight.com> Wed, 28 Sep 2011 23:55:48 +0200