cec: added vendor code for pioneer
[deb_libcec.git] / src / lib / devices / CECBusDevice.cpp
CommitLineData
e9de9629
LOK
1/*
2 * This file is part of the libCEC(R) library.
3 *
4 * libCEC(R) is Copyright (C) 2011 Pulse-Eight Limited. All rights reserved.
5 * libCEC(R) is an original work, containing original code.
6 *
7 * libCEC(R) is a trademark of Pulse-Eight Limited.
8 *
9 * This program is dual-licensed; you can redistribute it and/or modify
10 * it under the terms of the GNU General Public License as published by
11 * the Free Software Foundation; either version 2 of the License, or
12 * (at your option) any later version.
13 *
14 * This program is distributed in the hope that it will be useful,
15 * but WITHOUT ANY WARRANTY; without even the implied warranty of
16 * MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the
17 * GNU General Public License for more details.
18 *
19 * You should have received a copy of the GNU General Public License
20 * along with this program; if not, write to the Free Software
21 * Foundation, Inc., 59 Temple Place - Suite 330, Boston, MA 02111-1307, USA.
22 *
23 *
24 * Alternatively, you can license this library under a commercial license,
25 * please contact Pulse-Eight Licensing for more information.
26 *
27 * For more information contact:
28 * Pulse-Eight Licensing <license@pulse-eight.com>
29 * http://www.pulse-eight.com/
30 * http://www.pulse-eight.net/
31 */
32
33#include "CECBusDevice.h"
eafa9d46
LOK
34#include "../CECProcessor.h"
35#include "../implementations/ANCommandHandler.h"
36#include "../implementations/CECCommandHandler.h"
37#include "../implementations/SLCommandHandler.h"
38#include "../platform/timeutils.h"
e9de9629
LOK
39
40using namespace CEC;
41
42CCECBusDevice::CCECBusDevice(CCECProcessor *processor, cec_logical_address iLogicalAddress, uint16_t iPhysicalAddress) :
43 m_iPhysicalAddress(iPhysicalAddress),
44 m_iLogicalAddress(iLogicalAddress),
e55f3f70 45 m_powerStatus(CEC_POWER_STATUS_UNKNOWN),
e9de9629 46 m_processor(processor),
0ab58650 47 m_iVendorClass(CEC_VENDOR_UNKNOWN),
6a1c0009
LOK
48 m_iLastActive(0),
49 m_cecVersion(CEC_VERSION_UNKNOWN)
e9de9629
LOK
50{
51 m_handler = new CCECCommandHandler(this);
a3269a0a
LOK
52 for (unsigned int iPtr = 0; iPtr < 4; iPtr++)
53 m_menuLanguage.language[iPtr] = '?';
54 m_menuLanguage.language[3] = 0;
55 m_menuLanguage.device = iLogicalAddress;
0500da96 56 m_vendor.vendor = CEC_VENDOR_UNKNOWN;
e9de9629
LOK
57}
58
59CCECBusDevice::~CCECBusDevice(void)
60{
6a1c0009 61 m_condition.Broadcast();
e9de9629
LOK
62 delete m_handler;
63}
64
65cec_logical_address CCECBusDevice::GetMyLogicalAddress(void) const
66{
67 return m_processor->GetLogicalAddress();
68}
69
70uint16_t CCECBusDevice::GetMyPhysicalAddress(void) const
71{
72 return m_processor->GetPhysicalAddress();
73}
74
75void CCECBusDevice::AddLog(cec_log_level level, const CStdString &strMessage)
76{
77 m_processor->AddLog(level, strMessage);
78}
79
a3269a0a
LOK
80void CCECBusDevice::SetMenuLanguage(const cec_menu_language &language)
81{
82 if (language.device == m_iLogicalAddress)
83 {
84 CStdString strLog;
85 strLog.Format("device %d menu language set to '%s'", m_iLogicalAddress, language.language);
86 m_processor->AddLog(CEC_LOG_DEBUG, strLog);
87 m_menuLanguage = language;
88 }
89}
90
e55f3f70 91void CCECBusDevice::SetCecVersion(const cec_version newVersion)
6a1c0009
LOK
92{
93 CStdString strLog;
94 m_cecVersion = newVersion;
95
96 switch (newVersion)
97 {
98 case CEC_VERSION_1_2:
99 strLog.Format("device %d reports CEC version 1.2", m_iLogicalAddress);
100 break;
101 case CEC_VERSION_1_2A:
102 strLog.Format("device %d reports CEC version 1.2a", m_iLogicalAddress);
103 break;
104 case CEC_VERSION_1_3:
105 strLog.Format("device %d reports CEC version 1.3", m_iLogicalAddress);
106 break;
107 case CEC_VERSION_1_3A:
108 strLog.Format("device %d reports CEC version 1.3a", m_iLogicalAddress);
109 break;
110 default:
111 strLog.Format("device %d reports an unknown CEC version", m_iLogicalAddress);
112 m_cecVersion = CEC_VERSION_UNKNOWN;
113 break;
114 }
115 AddLog(CEC_LOG_DEBUG, strLog);
116}
117
e55f3f70
LOK
118void CCECBusDevice::SetPowerStatus(const cec_power_status powerStatus)
119{
b0271d54
LOK
120 if (m_powerStatus != powerStatus)
121 {
122 CStdString strLog;
123 strLog.Format("device %d power status changed from %2x to %2x", m_iLogicalAddress, m_powerStatus, powerStatus);
124 m_processor->AddLog(CEC_LOG_DEBUG, strLog);
125 m_powerStatus = powerStatus;
126 }
e55f3f70
LOK
127}
128
0f23c85c
LOK
129void CCECBusDevice::SetVendorId(const cec_datapacket &data)
130{
131 if (data.size < 3)
132 {
133 AddLog(CEC_LOG_WARNING, "invalid vendor ID received");
134 return;
135 }
136
137 uint64_t iVendorId = ((uint64_t)data[0] << 3) +
138 ((uint64_t)data[1] << 2) +
139 (uint64_t)data[2];
140
141 SetVendorId(iVendorId, data.size >= 4 ? data[3] : 0);
142}
143
2cd8b5d0 144void CCECBusDevice::SetVendorId(uint64_t iVendorId, uint8_t iVendorClass /* = 0 */)
e9de9629 145{
0500da96 146 m_vendor.vendor = (cec_vendor_id)iVendorId;
e9de9629
LOK
147 m_iVendorClass = iVendorClass;
148
149 switch (iVendorId)
150 {
151 case CEC_VENDOR_SAMSUNG:
0ab58650
LOK
152 if (m_handler->GetVendorId() != CEC_VENDOR_SAMSUNG)
153 {
154 delete m_handler;
155 m_handler = new CANCommandHandler(this);
156 }
e9de9629
LOK
157 break;
158 case CEC_VENDOR_LG:
0ab58650
LOK
159 if (m_handler->GetVendorId() != CEC_VENDOR_LG)
160 {
161 delete m_handler;
162 m_handler = new CSLCommandHandler(this);
163 }
e9de9629
LOK
164 break;
165 default:
0ab58650
LOK
166 if (m_handler->GetVendorId() != CEC_VENDOR_UNKNOWN)
167 {
168 delete m_handler;
169 m_handler = new CCECCommandHandler(this);
170 }
e9de9629
LOK
171 break;
172 }
173
174 CStdString strLog;
0f23c85c 175 strLog.Format("device %d: vendor = %s (%06x) class = %2x", m_iLogicalAddress, GetVendorName(), GetVendorId(), GetVendorClass());
e9de9629
LOK
176 m_processor->AddLog(CEC_LOG_DEBUG, strLog.c_str());
177}
178
179bool CCECBusDevice::HandleCommand(const cec_command &command)
180{
181 CLockObject lock(&m_mutex);
0ab58650 182 m_iLastActive = GetTimeMs();
e9de9629 183 m_handler->HandleCommand(command);
6a1c0009 184 m_condition.Signal();
e9de9629
LOK
185 return true;
186}
187
0500da96 188const cec_vendor &CCECBusDevice::GetVendor(void)
44c74256 189{
0500da96 190 if (m_vendor.vendor == CEC_VENDOR_UNKNOWN)
44c74256
LOK
191 {
192 AddLog(CEC_LOG_NOTICE, "<< requesting vendor ID");
193 cec_command command;
194 cec_command::format(command, GetMyLogicalAddress(), GetLogicalAddress(), CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
195 CLockObject lock(&m_mutex);
196
197 if (m_processor->Transmit(command))
198 m_condition.Wait(&m_mutex, 1000);
199 }
200
0500da96 201 return m_vendor;
44c74256
LOK
202}
203
0ab58650
LOK
204void CCECBusDevice::PollVendorId(void)
205{
206 CLockObject lock(&m_mutex);
0f23c85c 207 if (m_iLastActive > 0 && m_iLogicalAddress != CECDEVICE_BROADCAST &&
0500da96 208 m_vendor.vendor == CEC_VENDOR_UNKNOWN &&
0ab58650
LOK
209 GetTimeMs() - m_iLastActive > 5000)
210 {
211 m_iLastActive = GetTimeMs();
212
213 cec_command command;
214 cec_command::format(command, GetMyLogicalAddress(), GetLogicalAddress(), CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
a9e03a86
LOK
215 if (m_processor->Transmit(command))
216 m_condition.Wait(&m_mutex, 1000);
0ab58650
LOK
217 }
218}
219
4e4be5cf
LOK
220void CCECBusDevice::SetPhysicalAddress(uint16_t iNewAddress, uint16_t iOldAddress /* = 0 */)
221{
5eb9e3af
LOK
222 if (iNewAddress > 0)
223 {
224 CStdString strLog;
225 strLog.Format(">> %i changed physical address from %04x to %04x", GetLogicalAddress(), m_iPhysicalAddress, iNewAddress);
226 AddLog(CEC_LOG_DEBUG, strLog.c_str());
4e4be5cf 227
5eb9e3af
LOK
228 m_iPhysicalAddress = iNewAddress;
229 }
4e4be5cf
LOK
230}
231
0f23c85c
LOK
232bool CCECBusDevice::PowerOn(void)
233{
234 CStdString strLog;
235 strLog.Format("<< powering on device with logical address %d", (int8_t)m_iLogicalAddress);
236 AddLog(CEC_LOG_DEBUG, strLog.c_str());
237
238 cec_command command;
239 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_IMAGE_VIEW_ON);
240
241 return m_processor->Transmit(command);
242}
243
244bool CCECBusDevice::Standby(void)
245{
246 CStdString strLog;
247 strLog.Format("<< putting device with logical address %d in standby mode", (int8_t)m_iLogicalAddress);
248 AddLog(CEC_LOG_DEBUG, strLog.c_str());
249
250 cec_command command;
251 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_STANDBY);
252
253 return m_processor->Transmit(command);
254}
255
256bool CCECBusDevice::SetOSDString(cec_display_control duration, const char *strMessage)
257{
258 CStdString strLog;
259 strLog.Format("<< display message '%s'", strMessage);
260 AddLog(CEC_LOG_NOTICE, strLog.c_str());
261
262 cec_command command;
263 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_SET_OSD_STRING);
264 command.parameters.push_back((uint8_t)duration);
265
266 for (unsigned int iPtr = 0; iPtr < strlen(strMessage); iPtr++)
267 command.parameters.push_back(strMessage[iPtr]);
268
269 return m_processor->Transmit(command);
270}
271
272bool CCECBusDevice::ReportCECVersion(void)
273{
274 AddLog(CEC_LOG_NOTICE, "<< reporting CEC version as 1.3a");
275
276 cec_command command;
277 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_CEC_VERSION);
278 command.parameters.push_back(CEC_VERSION_1_3A);
279
280 return m_processor->Transmit(command);
281}
282
283bool CCECBusDevice::ReportDeckStatus(void)
284{
285 // need to support opcodes play and deck control before doing anything with this
286 AddLog(CEC_LOG_NOTICE, "<< deck status requested, feature abort");
287 m_processor->TransmitAbort(m_iLogicalAddress, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
288 return false;
289}
290
291bool CCECBusDevice::ReportMenuState(bool bActive /* = true */)
292{
293 if (bActive)
294 AddLog(CEC_LOG_NOTICE, "<< reporting menu state as active");
295 else
296 AddLog(CEC_LOG_NOTICE, "<< reporting menu state as inactive");
297
298 cec_command command;
299 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_MENU_STATUS);
300 command.parameters.push_back(bActive ? (uint8_t) CEC_MENU_STATE_ACTIVATED : (uint8_t) CEC_MENU_STATE_DEACTIVATED);
301
302 return m_processor->Transmit(command);
303}
304
305bool CCECBusDevice::ReportOSDName(void)
306{
307 const char *osdname = m_processor->GetDeviceName().c_str();
308 CStdString strLog;
309 strLog.Format("<< reporting OSD name as %s", osdname);
310 AddLog(CEC_LOG_NOTICE, strLog.c_str());
311
312 cec_command command;
313 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_SET_OSD_NAME);
314 for (unsigned int iPtr = 0; iPtr < strlen(osdname); iPtr++)
315 command.parameters.push_back(osdname[iPtr]);
316
317 return m_processor->Transmit(command);
318}
319
320bool CCECBusDevice::ReportPowerState(bool bOn /* = true */)
321{
322 if (bOn)
323 AddLog(CEC_LOG_NOTICE, "<< reporting \"On\" power status");
324 else
325 AddLog(CEC_LOG_NOTICE, "<< reporting \"Off\" power status");
326
327 cec_command command;
328 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_REPORT_POWER_STATUS);
329 command.parameters.push_back(bOn ? (uint8_t) CEC_POWER_STATUS_ON : (uint8_t) CEC_POWER_STATUS_STANDBY);
330
331 return m_processor->Transmit(command);
332}
333
334bool CCECBusDevice::ReportVendorID(void)
335{
336 AddLog(CEC_LOG_NOTICE, "<< vendor ID requested, feature abort");
337 m_processor->TransmitAbort(m_iLogicalAddress, CEC_OPCODE_GIVE_DEVICE_VENDOR_ID);
338 return false;
339}
340
341bool CCECBusDevice::BroadcastActiveView(void)
342{
343 AddLog(CEC_LOG_DEBUG, "<< setting active view");
344
345 cec_command command;
82b6ff53 346 cec_command::format(command, GetMyLogicalAddress(), CECDEVICE_BROADCAST, CEC_OPCODE_ACTIVE_SOURCE);
0f23c85c
LOK
347 command.parameters.push_back((m_iPhysicalAddress >> 8) & 0xFF);
348 command.parameters.push_back(m_iPhysicalAddress & 0xFF);
349
350 return m_processor->Transmit(command);
351}
352
353bool CCECBusDevice::BroadcastInactiveView(void)
354{
355 AddLog(CEC_LOG_DEBUG, "<< setting inactive view");
356
357 cec_command command;
82b6ff53 358 cec_command::format(command, GetMyLogicalAddress(), CECDEVICE_BROADCAST, CEC_OPCODE_INACTIVE_SOURCE);
0f23c85c
LOK
359 command.parameters.push_back((m_iPhysicalAddress >> 8) & 0xFF);
360 command.parameters.push_back(m_iPhysicalAddress & 0xFF);
361
362 return m_processor->Transmit(command);
363}
364
365bool CCECBusDevice::BroadcastPhysicalAddress(void)
366{
367 CStdString strLog;
368 strLog.Format("<< reporting physical address as %04x", m_iPhysicalAddress);
369 AddLog(CEC_LOG_NOTICE, strLog.c_str());
370
371 cec_command command;
82b6ff53 372 cec_command::format(command, GetMyLogicalAddress(), CECDEVICE_BROADCAST, CEC_OPCODE_REPORT_PHYSICAL_ADDRESS);
0f23c85c
LOK
373 command.parameters.push_back((uint8_t) ((m_iPhysicalAddress >> 8) & 0xFF));
374 command.parameters.push_back((uint8_t) (m_iPhysicalAddress & 0xFF));
375 command.parameters.push_back((uint8_t) (CEC_DEVICE_TYPE_PLAYBACK_DEVICE));
376
377 return m_processor->Transmit(command);
378}
379
380bool CCECBusDevice::BroadcastActiveSource(void)
381{
382 AddLog(CEC_LOG_NOTICE, "<< broadcasting active source");
383
384 cec_command command;
82b6ff53 385 cec_command::format(command, GetMyLogicalAddress(), CECDEVICE_BROADCAST, CEC_OPCODE_ACTIVE_SOURCE);
0f23c85c
LOK
386 command.parameters.push_back((uint8_t) ((m_iPhysicalAddress >> 8) & 0xFF));
387 command.parameters.push_back((uint8_t) (m_iPhysicalAddress & 0xFF));
388
389 return m_processor->Transmit(command);
390}
391
8acf4aac 392cec_version CCECBusDevice::GetCecVersion(bool bRefresh /* = true */)
6a1c0009 393{
8acf4aac 394 if (bRefresh || m_cecVersion == CEC_VERSION_UNKNOWN)
6a1c0009
LOK
395 {
396 AddLog(CEC_LOG_NOTICE, "<< requesting CEC version");
397 cec_command command;
398 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GET_CEC_VERSION);
399 CLockObject lock(&m_mutex);
400 if (m_processor->Transmit(command))
401 m_condition.Wait(&m_mutex, 1000);
402 }
403
404 return m_cecVersion;
405}
406
8acf4aac 407cec_menu_language &CCECBusDevice::GetMenuLanguage(bool bRefresh /* = true */)
a3269a0a 408{
8acf4aac 409 if (bRefresh || !strcmp(m_menuLanguage.language, "???"))
a3269a0a
LOK
410 {
411 AddLog(CEC_LOG_NOTICE, "<< requesting menu language");
412 cec_command command;
413 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GET_MENU_LANGUAGE);
414 CLockObject lock(&m_mutex);
415 if (m_processor->Transmit(command))
416 m_condition.Wait(&m_mutex, 1000);
417 }
418
419 return m_menuLanguage;
420}
421
8acf4aac 422cec_power_status CCECBusDevice::GetPowerStatus(bool bRefresh /* = true */)
e55f3f70 423{
8acf4aac 424 if (bRefresh || m_powerStatus == CEC_POWER_STATUS_UNKNOWN)
e55f3f70
LOK
425 {
426 AddLog(CEC_LOG_NOTICE, "<< requesting power status");
427 cec_command command;
428 cec_command::format(command, GetMyLogicalAddress(), m_iLogicalAddress, CEC_OPCODE_GIVE_DEVICE_POWER_STATUS);
429 CLockObject lock(&m_mutex);
430 if (m_processor->Transmit(command))
431 m_condition.Wait(&m_mutex, 1000);
432 }
433
434 return m_powerStatus;
435}