X-Git-Url: https://git.piment-noir.org/?p=deb_libcec.git;a=blobdiff_plain;f=ChangeLog;h=862c347b339b459867e8d5d7049d59c1ba94dd8a;hp=a1ccd6822ecb0a95899391545f27424e682a819d;hb=b1bd94283cef75676b987f30d61f26fad09c19c3;hpb=cf34f9fd4c28854152a995bdc9243b8a7bb893a1 diff --git a/ChangeLog b/ChangeLog index a1ccd68..862c347 100644 --- a/ChangeLog +++ b/ChangeLog @@ -1,3 +1,188 @@ +libcec (2.2.0-1) unstable; urgency=low + + * changed / added: + * read the physical address from X11 randr extension. credits: @smithereens + * support for Exynos HDMI. credits: @vamanea + * another vendor ID for Harman/Kardon. credits: @ksooo + * some 1.4 keycodes have been added. credits: @ksooo + * cec-client: fix typo prevent keycodes to be passed. credits: @popcornmix + + * fixed: + * various Raspberry Pi fixes. credits: @mk01 + * vendor specific handlers weren't used for Toshiba and Onkyo. + credits: @ksooo + * LibCecTray: keypress not sent when multiple instances of eshell.exe are + running. thanks @pvanbaren + * deadlock on exit in XBMC, because of CEC_ALERT_CONNECTION_LOST + + -- Pulse-Eight Packaging Tue, 28 Oct 2014 10:45:00 +0200 + +libcec (2.1.4-2) unstable; urgency=low + + * fixed: + * OS X build + + -- Pulse-Eight Packaging Wed, 18 Dec 2013 02:14:00 +0100 + +libcec (2.1.4-1) unstable; urgency=low + + * changed / added: + * set the vendor id of devices handled by libCEC to our vendor id + * added protection against standby without a notification from XBMC and + clock changes. issue #186 + * update system audio mode when audio system devices are activated + * added vendor id and name 'Harman/Kardon' + * added vendor id and name 'Marantz' + * cec-tray: support for away mode + * cec-tray: support for screensaver events + * fixed: + * fixed potential crash when SendCommand returns NULL + * fixed crash when CCECProcessor::Transmit was called after + CCECProcessor::Close + * always call the SourceActivated() callback in + CCECBusDevice::MarkAsActiveSource(), even when we were already active, + and let clients handle dupes. this prevented the screensaver from + being cancelled in XBMC + * send our vendor id when the tv sends it's vendor id + * transmit our physical address when the TV sends it's physical address + * potential deadlock + * leak on exit in CWaitForResponse::Clear() + * also transmit an active source message as response to a set stream path + command when we were already marked as active. bugzid: 3116 + * only send an active source message when receiving a routing change to an + address handled by libCEC. issue #56 + * HandleVendorRemoteButtonUp -> HandleUserControlRelease for all vendors + * silence warning for xx:a0:00:09:b0:00:80:20. bugzid: 2559 + * fixed comboKeyTimeout=0. closes #168 + * Panasonic: doesn't request the active source status when powered up, but + it does send a vendor command. send an active source message when we're + marked as active source after receiving this command. issue #192 + * possible crash when the tv does not respond to polls and the client isn't + registered yet. don't poll the tv in monitoring mode. closes #163 + * Panasonic: standby command + * Panasonic: silence 'unmapped code' warning. bugzid: 2375 + * LG: clean up and attempt to fix issue #176 + * LG: newer firmwares don't send a second power status request after it's + been requested once and replied with 'standby -> on' like previous + versions. send an active source message in an attempt to fix this. issue: + #176 + * Sharp: check whether the 'auto power on' option is disabled and tell the + user how to enable it + * Samsung: respond to vendor command 0x23 sent by samsung. attempt to fix + bugzid: 2164 + * cec-client: try to reconnect when the connection was lost + * cec-tray: crash on load (MissingManifestResourceException) + * cec-tray: crash or deadlock on exit + * cec-tray: crash when the connection to the adapter was lost + * cec-tray: display TV not responding warning on top + * windows: build libCEC and cec-client against toolset v100 (VS2010) + * FreeBSD: proper the adapter detection. credits @fneufneu + * suppress mangling warning. credits @warped-rudi. closes #190 + + -- Pulse-Eight Packaging Sat, 13 Dec 2013 16:02:00 +0100 + +libcec (2.1.3-1) unstable; urgency=low + + * changed / added: + * ask users to send an email when receiving an unhandled vendor command + * toshiba: map top menu and dvd menu buttons. closes #148 + * LibCecSharp: sync alert types + * LibCecSharp: added CurrentVersion to the version enum + * CecSharpClient: use CurrentVersion instead of a hardcoded version + * CecTray: power management + * CecTray: split up asyncform + * CecTray: try/catch xml exceptions when reading the xml config. bugzid: + 2082 + * CecTray: use CurrentVersion instead of a hardcoded version + * CecTray: display a warning if we can't poll the TV + * CecTray: display alerts from libCEC + * CecTray: don't use lazy loading for the main controller, but pass the + instance. bugzid: 2082 + * windows: converted to vs2012 + * fixed: + * toshiba: toshiba handler wasn't initialised, and toshiba uses more than + one vendor id + * libCEC marked itself as inactive source when the stream path changed to + a device with a different physical address. bugzid: 2157 + * TDA995x: report proper firmware revision (credits: @warped-rudi) + * TDA995x: avoid callback when already stopped (credits: @warped-rudi) + * windows: fix resource files and backwards compat dll names + + -- Pulse-Eight Packaging Sat, 11 May 2013 10:06:00 +0000 + +libcec (2.1.1-1) unstable; urgency=low + + * changed / added: + * send an alert when the TV does not respond to polls + * fixed: + * LG didn't switch sources after the TV powered up + * always poll a device when the status is unknown, and don't try to + determine whether it needs to be polled by checking the status of other + devices + * don't mark a device as inactive when receiving a routing change message, + only when another device was made acive. fixes the issue that rc + passthrough doesn't work when a tv sends a quick routing change to + another port before requesting the active source when coming out of + standby + * LibCecSharp: fixed 14 char long OSD name (wasn't \0 terminated) + * LibCecSharp: fixed return value of GetActiveDevices(). issue #131 + * cec-tray: fixed index out of range exception in CECSettingNumeric.cs. + bugzid: 2082 + * cec-tray: ensure that the tray app only initialises once. bugzid: 2082 + * rpi: don't set the physical address to 1.0.0.0 when receiving + VC_HDMI_UNPLUGGED. it may wake up device when they were just sent to + standby. issue #142 + * osx: use the correct dylib name in cecloader.h, used by cec-client + + -- Pulse-Eight Packaging Fri, 8 Mar 2013 17:21:00 +0100 + + libcec (2.1.0-1) unstable; urgency=low + + * changed / added: + * added vendor id for Denon + * added DetectAdapters() method, that returns all device information for + detected adapters, not just the com port + * added new method PowerOnScreensaver. credits: @jmarcet + * LibCECTray: Added ability to send modifiers by nesting commands in + KeyInput.cs. credits: Nate Burr + * rpi: Added /opt/vc/include/interface/vmcs_host/linux to rpi_cflags to fix + building on 'next' firmware branch. credits: Nedim Lisica + * fixed: + * don't send two active source message sequences to philips. issue #118 + * don't send deck status updates to philips when activating the source + * update the active source status correctly after a manual switch to + another source. closes #124 + * rename cec_audio_status() to cec_audio_get_status() to avoid conflict + with the cec_audio_status enum. This makes the C API compile again. + credits: Dave Chapman + * LibCECTray: Fixed bug with libcec adding the keyup for button commands + and making sure they are still executed. credits: Nate Burr + * rpi: register callback for HPD. re-read the physical address when we + received VC_HDMI_ATTACHED. issue #109 + + -- Pulse-Eight Packaging Tue, 26 Feb 2013 23:06:00 +0100 + +libcec (2.0.5-1) unstable; urgency=low + + * changed: + * also try polls at least twice when it failed + * added methods to get the audiostatus and toggle the mute status from the + amplifier (if connected) + * added comboKey and iComboKeyTimeoutMs to libcec_configuration + * force cec_user_control_code_unknown to 0xFF + * fixed: + * check unsupported features properly + * only send an active source message when the stream path changed and we + weren't the active source yet + * don't mark as inactive source on routing changes + * press & hold + * never mark user control opcodes as unsupported + * report our OSD name to the TV, since some TVs don't request it + * initial audiostatus value + * don't log a no longer relevant FIXME + + -- Pulse-Eight Packaging Thu, 6 Dec 2012 20:58:00 +0100 + libcec (2.0.4-1) unstable; urgency=low * changed: