Fix project name in dep5 file
[e-mobility-charging-stations-simulator.git] / README.md
CommitLineData
1ea2264a 1# [e-mobility charging stations simulator](https://github.com/sap/e-mobility-charging-stations-simulator)
7dde0b73
JB
2
3## Summary
4
ccb1d6e9 5Simple [node.js](https://nodejs.org/) software to simulate a set of charging stations based on the OCPP-J 1.6 protocol as part of SAP e-Mobility solution.
7dde0b73 6
696ce53a
JB
7## Prerequisites
8
9### Windows
10
e7aeea18 11- [Chocolatey](https://chocolatey.org/):
696ce53a
JB
12
13```powershell
14choco install -y nodejs-lts
15```
16
17### MacOSX
18
e7aeea18 19- [Homebrew](https://brew.sh/):
696ce53a
JB
20
21```shell
8f3d04b0 22brew install node@16
696ce53a
JB
23```
24
e7aeea18 25### GNU/Linux:
511780c3 26
11d8f3e9 27- [NodeSource](https://github.com/nodesource/distributions) Node.js Binary Distributions for version 16.X
511780c3 28
4d3821a2 29## Configuration files syntax
2c28fc83 30
e7aeea18 31All configuration files are in the JSON standard format.
2c28fc83 32
1816f743 33**Configuration files list**:
2c28fc83 34
170bec53 35- charging stations simulator configuration: [src/assets/config.json](src/assets/config.json);
1816f743 36- charging station configuration templates: [src/assets/station-templates](src/assets/station-templates);
1c51fd1d 37- charging station configurations: [dist/assets/configurations](dist/assets/configurations);
7f818162 38- charging station RFID tags lists: [src/assets](src/assets).
2c28fc83 39
1816f743
JB
40The charging stations simulator's configuration parameters must be within the `src/assets/config.json` file. A charging station simulator configuration template file is available at [src/assets/config-template.json](src/assets/config-template.json).
41
42All charging station configuration templates are in the directory [src/assets/station-templates](src/assets/station-templates).
43
44A list of RFID tags must be defined for the automatic transaction generator with a default location and name: `src/assets/authorization-tags.json`. A template file is available at [src/assets/authorization-tags-template.json](src/assets/authorization-tags-template.json).
45
46**Configuration files hierarchy and priority**:
47
1c51fd1d 481. charging station configuration: [dist/assets/configurations](dist/assets/configurations);
1816f743 492. charging station configuration template: [src/assets/station-templates](src/assets/station-templates);
170bec53 503. charging stations simulator configuration: [src/assets/config.json](src/assets/config.json).
511780c3 51
e7aeea18 52The charging stations simulator have an automatic configuration files reload feature at change for:
511780c3 53
170bec53 54- charging stations simulator configuration;
1816f743 55- charging station configuration templates;
170bec53 56- charging station authorization RFID tags lists.
2c28fc83 57
e7aeea18
JB
58But the modifications to test have to be done to the files in the build result directory [dist/assets](dist/assets). Once the modifications are finished, they have to be reported or copied to the matching files in the build source directory [src/assets](src/assets) to ensure they will be taken into account at next build.
59
170bec53 60### Charging stations simulator configuration
2c28fc83 61
b1d6e944 62**src/assets/config.json**:
2c28fc83 63
1816f743
JB
64| Key | Value(s) | Default Value | Value type | Description |
65| -------------------------- | ------------------------------------------------ | --------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------- |
66| supervisionUrls | | [] | string \| string[] | string or array of global connection URIs to OCPP-J servers |
67| supervisionUrlDistribution | round-robin/random/sequential | round-robin | boolean | supervision urls distribution policy to simulated charging stations |
68| workerProcess | workerSet/staticPool/dynamicPool | workerSet | string | worker threads process type |
69| workerStartDelay | | 500 | integer | milliseconds to wait at worker threads startup (only for workerSet threads process type) |
70| elementStartDelay | | 0 | integer | milliseconds to wait at charging station startup |
71| workerPoolMinSize | | 4 | integer | worker threads pool minimum number of threads |
72| workerPoolMaxSize | | 16 | integer | worker threads pool maximum number of threads |
73| workerPoolStrategy | ROUND_ROBIN/LESS_RECENTLY_USED/... | [poolifier](https://github.com/poolifier/poolifier) default: ROUND_ROBBIN | string | worker threads pool [poolifier](https://github.com/poolifier/poolifier) worker choice strategy |
74| chargingStationsPerWorker | | 1 | integer | number of charging stations per worker threads for the `workerSet` process type |
75| logStatisticsInterval | | 60 | integer | seconds between charging stations statistics output in the logs |
76| logConsole | true/false | false | boolean | output logs on the console |
77| logFormat | | simple | string | winston log format |
78| logRotate | true/false | true | boolean | enable daily log files rotation |
79| logMaxFiles | | 7 | integer | maximum number of log files to keep |
80| logLevel | emerg/alert/crit/error/warning/notice/info/debug | info | string | winston logging level |
81| logFile | | combined.log | string | log file relative path |
82| logErrorFile | | error.log | string | error log file relative path |
675fa8e3 83| uiServer | | { "enabled": true, "options": { "host: "localhost", "port": 8080 } } | { enabled: boolean; options: ServerOptions; } | UI WebSocket server configuration section |
1816f743
JB
84| performanceStorage | | { "enabled": false, "type": "jsonfile", "file:///performanceRecords.json" } | { enabled: boolean; type: string; URI: string; } where type can be 'jsonfile' or 'mongodb' | performance storage configuration section |
85| stationTemplateUrls | | {}[] | { file: string; numberOfStations: number; }[] | array of charging station configuration templates URIs configuration section (charging station configuration template file name and number of stations) |
e7aeea18
JB
86
87#### Worker process model:
a6b3c6c3
JB
88
89- **workerSet**:
90 Worker set executing each a static number (chargingStationsPerWorker) of simulated charging stations from the total
91
92- **staticPool**:
e7aeea18 93 Statically sized worker pool executing a static total number of simulated charging stations
a6b3c6c3
JB
94
95- **dynamicPool**:
e7aeea18 96 Dynamically sized worker pool executing a static total number of simulated charging stations
a6b3c6c3 97
1816f743
JB
98### Charging station configuration template
99
afccb423 100**src/assets/station-templates/\<name\>.json**:
1816f743 101
ccb1d6e9
JB
102| Key | Value(s) | Default Value | Value type | Description |
103| ---------------------------------- | ---------- | --------------- | --------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
104| supervisionUrls | | '' | string \| string[] | string or array of connection URIs to OCPP-J servers |
105| supervisionUser | | '' | string | basic HTTP authentication user to OCPP-J server |
106| supervisionPassword | | '' | string | basic HTTP authentication password to OCPP-J server |
107| supervisionUrlOcppConfiguration | true/false | false | boolean | allow supervision URL configuration via a vendor OCPP parameter key |
108| supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL |
109| ocppVersion | 1.6 | 1.6 | string | OCPP version |
110| ocppProtocol | json | json | string | OCPP protocol |
111| ocppStrictCompliance | true/false | false | boolean | strict adherence to the OCPP version and protocol specifications |
112| ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in dist/assets/configurations |
113| stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in dist/assets/configurations |
114| wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection |
115| authorizationFile | | '' | string | RFID tags list file relative to src/assets path |
116| baseName | | '' | string | base name to build charging stations id |
117| nameSuffix | | '' | string | name suffix to build charging stations id |
118| fixedName | true/false | false | boolean | use the baseName as the charging stations unique name |
119| chargePointModel | | '' | string | charging stations model |
120| chargePointVendor | | '' | string | charging stations vendor |
121| chargePointSerialNumberPrefix | | '' | string | charge point serial number prefix |
122| chargeBoxSerialNumberPrefix | | '' | string | charge box serial number prefix (deprecated in OCPP 1.6) |
123| firmwareVersion | | '' | string | charging stations firmware version |
124| power | | | float \| float[] | charging stations maximum power value(s) |
125| powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors |
126| powerUnit | W/kW | W | string | charging stations power unit |
127| currentOutType | AC/DC | AC | string | charging stations current out type |
128| voltageOut | | AC:230/DC:400 | integer | charging stations voltage out |
129| numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) |
130| numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) |
131| useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template |
132| randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template |
133| resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset |
134| autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose |
135| autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server |
136| reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server |
137| registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries |
138| amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC |
139| amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit |
140| enableStatistics | true/false | true | boolean | enable charging stations statistics |
141| mayAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled |
142| beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues |
143| outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) |
144| meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis |
145| transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction |
146| mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations |
147| phaseLineToLineVoltageMeterValues | true/false | true | boolean | include charging stations line to line voltage MeterValues on three phased charging stations |
148| customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues |
149| Configuration | | | ChargingStationConfiguration | charging stations OCPP parameters configuration section |
150| AutomaticTransactionGenerator | | | AutomaticTransactionGenerator | charging stations ATG configuration section |
151| Connectors | | | Connectors | charging stations connectors configuration section |
c94a349a
JB
152
153#### Configuration section
154
155```json
0302da79 156 "Configuration": {
c94a349a
JB
157 "configurationKey": [
158 ...
159 {
160 "key": "StandardKey",
161 "readonly": false,
162 "value": "StandardValue",
163 "visible": true,
164 "reboot": false
165 },
166 ...
167 {
168 "key": "VendorKey",
169 "readonly": false,
170 "value": "VendorValue",
171 "visible": false,
172 "reboot": true
173 },
174 ...
175 ]
176 }
177```
178
179#### AutomaticTransactionGenerator section
180
181```json
0302da79 182 "AutomaticTransactionGenerator": {
c94a349a
JB
183 "enable": false,
184 "minDuration": 60,
185 "maxDuration": 80,
186 "minDelayBetweenTwoTransactions": 15,
187 "maxDelayBetweenTwoTransactions": 30,
188 "probabilityOfStart": 1,
189 "stopAfterHours": 0.3,
190 "stopOnConnectionFailure": true,
e644918b 191 "requireAuthorize": true
c94a349a
JB
192 }
193```
e7aeea18 194
c94a349a
JB
195#### Connectors section
196
197```json
0302da79 198 "Connectors": {
c94a349a
JB
199 "0": {},
200 "1": {
201 "bootStatus": "Available",
202 "MeterValues": [
9bd87386
JB
203 ...
204 {
205 "unit": "W",
206 "measurand": "Power.Active.Import",
207 "phase": "L1-N",
208 "value": "5000",
209 "fluctuationPercent": "10"
210 },
c94a349a
JB
211 ...
212 {
213 "unit": "A",
214 "measurand": "Current.Import"
215 },
216 ...
217 {
218 "unit": "Wh"
219 },
220 ...
221 ]
222 }
223 },
224```
225
1816f743
JB
226### Charging station configuration
227
1c51fd1d 228**dist/assets/configurations/\<hashId\>.json**:
1816f743 229
a9ec2018 230The charging station configuration file is automatically generated at startup from the charging station configuration template file and is persistent.
1816f743
JB
231
232The charging station configuration file content can be regenerated partially on matching charging station configuration template file changes. The charging station serial number is kept unchanged.
233
234#### stationInfo section
235
236The syntax is similar to charging station configuration template with some added fields like the charging station id (name) and the 'Configuration' section removed.
237
238#### configurationKey section
239
240The syntax is similar to the charging station configuration template 'Configuration' section.
241
6f0ec20e
JB
242## Start
243
244To start the program, run: `npm start`.
245
175d4f46 246To start the program with a UI controller, run: `npm start:server`.
903becc3 247Then, start/stop the simulator by going to `https://<hostname:port>` in a browser. Localhost port will default to 8080. For Cloud Foundry, the port is assigned based on the `process.env.PORT` environment variable.
175d4f46 248
6f0ec20e
JB
249## Docker
250
251In the [docker](./docker) folder:
252
253```bash
254make
255```
256
bfcad885 257Or with the optional git submodules:
6f0ec20e
JB
258
259```bash
bfcad885 260make SUBMODULES_INIT=true
6f0ec20e
JB
261```
262
263## OCPP-J commands supported
c94a349a
JB
264
265### Version 1.6
266
c56d42f1 267#### Core Profile
6f0ec20e 268
778f7924
JB
269- :white_check_mark: Authorize
270- :white_check_mark: BootNotification
271- :white_check_mark: ChangeAvailability
272- :white_check_mark: ChangeConfiguration
273- :white_check_mark: ClearCache
9e1b12e4 274- :x: DataTransfer
778f7924
JB
275- :white_check_mark: GetConfiguration
276- :white_check_mark: Heartbeat
277- :white_check_mark: MeterValues
278- :white_check_mark: RemoteStartTransaction
279- :white_check_mark: RemoteStopTransaction
280- :white_check_mark: Reset
281- :white_check_mark: StartTransaction
282- :white_check_mark: StatusNotification
283- :white_check_mark: StopTransaction
284- :white_check_mark: UnlockConnector
6f0ec20e 285
c56d42f1 286#### Firmware Management Profile
6f0ec20e 287
b652b0c3 288- :white_check_mark: GetDiagnostics
d50343bd 289- :white_check_mark: DiagnosticsStatusNotification
9e1b12e4
JB
290- :x: FirmwareStatusNotification
291- :x: UpdateFirmware
6f0ec20e 292
c56d42f1 293#### Local Auth List Management Profile
6f0ec20e 294
9e1b12e4
JB
295- :x: GetLocalListVersion
296- :x: SendLocalList
6f0ec20e 297
c56d42f1 298#### Reservation Profile
6f0ec20e 299
9e1b12e4
JB
300- :x: CancelReservation
301- :x: ReserveNow
6f0ec20e 302
c56d42f1 303#### Smart Charging Profile
6f0ec20e 304
778f7924 305- :white_check_mark: ClearChargingProfile
68cb8b91 306- :x: GetCompositeSchedule
778f7924 307- :white_check_mark: SetChargingProfile
6f0ec20e 308
c56d42f1 309#### Remote Trigger Profile
6f0ec20e 310
802cfa13 311- :white_check_mark: TriggerMessage
7dde0b73 312
7e1dc878
JB
313## OCPP-J standard parameters supported
314
1816f743 315All kind of OCPP parameters are supported in a charging station configuration or a charging station configuration template file. The list here mention the standard ones also handled automatically in the simulator.
7e1dc878
JB
316
317### Version 1.6
318
c56d42f1 319#### Core Profile
7e1dc878
JB
320
321- :white_check_mark: AuthorizeRemoteTxRequests (type: boolean) (units: -)
322- :x: ClockAlignedDataInterval (type: integer) (units: seconds)
291cb255 323- :white_check_mark: ConnectionTimeOut (type: integer) (units: seconds)
7e1dc878
JB
324- :x: GetConfigurationMaxKeys (type: integer) (units: -)
325- :white_check_mark: HeartbeatInterval (type: integer) (units: seconds)
326- :x: LocalAuthorizeOffline (type: boolean) (units: -)
327- :x: LocalPreAuthorize (type: boolean) (units: -)
328- :x: MeterValuesAlignedData (type: CSL) (units: -)
329- :white_check_mark: MeterValuesSampledData (type: CSL) (units: -)
330- :white_check_mark: MeterValueSampleInterval (type: integer) (units: seconds)
331- :white_check_mark: NumberOfConnectors (type: integer) (units: -)
332- :x: ResetRetries (type: integer) (units: times)
333- :white_check_mark: ConnectorPhaseRotation (type: CSL) (units: -)
334- :x: StopTransactionOnEVSideDisconnect (type: boolean) (units: -)
335- :x: StopTransactionOnInvalidId (type: boolean) (units: -)
336- :x: StopTxnAlignedData (type: CSL) (units: -)
337- :x: StopTxnSampledData (type: CSL) (units: -)
36f6a92e 338- :white_check_mark: SupportedFeatureProfiles (type: CSL) (units: -)
7e1dc878
JB
339- :x: TransactionMessageAttempts (type: integer) (units: times)
340- :x: TransactionMessageRetryInterval (type: integer) (units: seconds)
341- :x: UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -)
36f6a92e 342- :white_check_mark: WebSocketPingInterval (type: integer) (units: seconds)
7e1dc878 343
c56d42f1 344#### Firmware Management Profile
7e1dc878 345
e7aeea18 346- _none_
7e1dc878 347
c56d42f1 348#### Local Auth List Management Profile
7e1dc878 349
36f6a92e 350- :white_check_mark: LocalAuthListEnabled (type: boolean) (units: -)
7e1dc878
JB
351- :x: LocalAuthListMaxLength (type: integer) (units: -)
352- :x: SendLocalListMaxLength (type: integer) (units: -)
353
c56d42f1 354#### Reservation Profile
7e1dc878 355
e7aeea18 356- _none_
7e1dc878 357
c56d42f1 358#### Smart Charging Profile
7e1dc878
JB
359
360- :x: ChargeProfileMaxStackLevel (type: integer) (units: -)
361- :x: ChargingScheduleAllowedChargingRateUnit (type: CSL) (units: -)
362- :x: ChargingScheduleMaxPeriods (type: integer) (units: -)
363- :x: MaxChargingProfilesInstalled (type: integer) (units: -)
364
c56d42f1 365#### Remote Trigger Profile
7e1dc878 366
e7aeea18 367- _none_
7e1dc878 368
251fff5c 369## Support, Feedback, Contributing
7dde0b73 370
7f774a55 371This project is open to feature requests/suggestions, bug reports etc. via [GitHub issues](https://github.com/SAP/e-mobility-charging-stations-simulator/issues). Contribution and feedback are encouraged and always welcome. For more information about how to contribute, the project structure, as well as additional contribution information, see our [Contribution Guidelines](CONTRIBUTING.md).
7dde0b73 372
251fff5c
JB
373## Code of Conduct
374
375We as members, contributors, and leaders pledge to make participation in our community a harassment-free experience for everyone. By participating in this project, you agree to abide by its [Code of Conduct](CODE_OF_CONDUCT.md) at all times.
376
377## Licensing
378
7f774a55 379Copyright 2020-2022 SAP SE or an SAP affiliate company and e-mobility-charging-stations-simulator contributors. Please see our [LICENSE](LICENSE) for copyright and license information. Detailed information including third-party components and their licensing/copyright information is available [via the REUSE tool](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator).