fix: reference a connector status clone in connectors map
[e-mobility-charging-stations-simulator.git] / README.md
CommitLineData
d6b76da3 1<!-- markdownlint-disable-file MD033 MD024 -->
9e0845f7 2
1ea2264a 3# [e-mobility charging stations simulator](https://github.com/sap/e-mobility-charging-stations-simulator)
7dde0b73 4
4d188eb9 5[![REUSE status](https://api.reuse.software/badge/github.com/SAP/e-mobility-charging-stations-simulator)](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator)
0a3d08ef 6
7dde0b73
JB
7## Summary
8
fd405348 9Simple [node.js](https://nodejs.org/) software to simulate and scale a set of charging stations based on the OCPP-J 1.6 protocol as part of SAP e-Mobility solution.
7dde0b73 10
696ce53a
JB
11## Prerequisites
12
5845e83d 13Install the [node.js](https://nodejs.org/) current LTS or superior version runtime environment:
007ee642 14
696ce53a
JB
15### Windows
16
e7aeea18 17- [Chocolatey](https://chocolatey.org/):
696ce53a
JB
18
19```powershell
5845e83d 20choco install -y nodejs
696ce53a
JB
21```
22
23### MacOSX
24
e7aeea18 25- [Homebrew](https://brew.sh/):
696ce53a
JB
26
27```shell
5845e83d 28brew install node
696ce53a
JB
29```
30
d6b76da3 31### GNU/Linux
511780c3 32
7e901376 33- [NodeSource](https://github.com/nodesource/distributions) Node.js Binary Distributions for version >= 16.X
511780c3 34
007ee642
JB
35## Installation
36
1a662d29 37Enable corepack if not already done and install latest pnpm version:
5845e83d
JB
38
39```shell
40corepack enable
1a662d29 41corepack prepare pnpm@latest --activate
5845e83d
JB
42```
43
007ee642
JB
44In the repository root, run the following command:
45
46```shell
881f450c 47pnpm install
007ee642
JB
48```
49
50## Initial configuration
51
db70b600 52Copy the configuration template file [src/assets/config-template.json](src/assets/config-template.json) to [src/assets/config.json](src/assets/config.json).
e302df1d 53Copy the RFID tags template file [src/assets/idtags-template.json](src/assets/idtags-template.json) to [src/assets/idtags.json](src/assets/idtags.json).
db70b600
JB
54
55Tweak them to your needs by following the section [configuration files syntax](README.md#configuration-files-syntax).
007ee642
JB
56
57## Start
58
881f450c 59To start the program, run: `pnpm start`.
007ee642 60
4e3ff94d 61## Start Web UI
007ee642 62
ebbfbf1c 63See Web UI [README.md](ui/web/README.md) for more information.
b8cc885d 64
4d3821a2 65## Configuration files syntax
2c28fc83 66
e7aeea18 67All configuration files are in the JSON standard format.
2c28fc83 68
ff82dc5f 69**Configuration files locations**:
2c28fc83 70
170bec53 71- charging stations simulator configuration: [src/assets/config.json](src/assets/config.json);
1816f743 72- charging station configuration templates: [src/assets/station-templates](src/assets/station-templates);
1c51fd1d 73- charging station configurations: [dist/assets/configurations](dist/assets/configurations);
7f818162 74- charging station RFID tags lists: [src/assets](src/assets).
2c28fc83 75
1816f743
JB
76The charging stations simulator's configuration parameters must be within the `src/assets/config.json` file. A charging station simulator configuration template file is available at [src/assets/config-template.json](src/assets/config-template.json).
77
78All charging station configuration templates are in the directory [src/assets/station-templates](src/assets/station-templates).
79
e302df1d 80A list of RFID tags must be defined for the automatic transaction generator in a file with a default location and name: `src/assets/idtags.json`. A template file is available at [src/assets/idtags-template.json](src/assets/idtags-template.json).
1816f743
JB
81
82**Configuration files hierarchy and priority**:
83
1c51fd1d 841. charging station configuration: [dist/assets/configurations](dist/assets/configurations);
1816f743 852. charging station configuration template: [src/assets/station-templates](src/assets/station-templates);
170bec53 863. charging stations simulator configuration: [src/assets/config.json](src/assets/config.json).
511780c3 87
e7aeea18 88The charging stations simulator have an automatic configuration files reload feature at change for:
511780c3 89
170bec53 90- charging stations simulator configuration;
1816f743 91- charging station configuration templates;
170bec53 92- charging station authorization RFID tags lists.
2c28fc83 93
c645fe94 94But the modifications to test have to be done to the files in the build target directory [dist/assets](dist/assets). Once the modifications are finished, they have to be reported or copied to the matching files in the build source directory [src/assets](src/assets) to ensure they will be taken into account at next build.
e7aeea18 95
170bec53 96### Charging stations simulator configuration
2c28fc83 97
b1d6e944 98**src/assets/config.json**:
2c28fc83 99
19dbb570
JB
100| Key | Value(s) | Default Value | Value type | Description |
101| -------------------------- | ------------------------------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
102| supervisionUrls | | [] | string \| string[] | string or array of global connection URIs to OCPP-J servers |
103| supervisionUrlDistribution | round-robin/random/charging-station-affinity | charging-station-affinity | boolean | supervision urls distribution policy to simulated charging stations |
104| logStatisticsInterval | | 60 | integer | seconds between charging stations statistics output in the logs |
105| logConsole | true/false | false | boolean | output logs on the console |
21899fc2 106| logFormat | | simple | string | [winston](https://github.com/winstonjs/winston) log format |
38cc3b4b 107| logRotate | true/false | true | boolean | enable daily log files rotation |
37e868f2
JB
108| logMaxFiles | x/"xd" where x is an integer | undefined | integer \| string | maximum number of log files: https://github.com/winstonjs/winston-daily-rotate-file#options |
109| logMaxSize | x/"xk"/"xm"/"xg" where x is a number | undefined | number \| string | maximum size of log files in bytes, or units of kb, mb, and gb: https://github.com/winstonjs/winston-daily-rotate-file#options |
21899fc2 110| logLevel | emerg/alert/crit/error/warning/notice/info/debug | info | string | [winston](https://github.com/winstonjs/winston) logging level |
19dbb570
JB
111| logFile | | combined.log | string | log file relative path |
112| logErrorFile | | error.log | string | error log file relative path |
113| worker | | {<br />"processType": "workerSet",<br />"startDelay": 500,<br />"elementStartDelay": 0,<br />"elementsPerWorker": 1,<br />"poolMinSize": 4,<br />"poolMaxSize": 16,<br />"poolStrategy": "ROUND_ROBIN"<br />} | {<br />processType: WorkerProcessType;<br />startDelay: number;<br />elementStartDelay: number;<br />elementsPerWorker: number;<br />poolMinSize: number;<br />poolMaxSize: number;<br />poolStrategy: WorkerChoiceStrategy;<br />} | Worker configuration section:<br />- processType: worker threads process type (workerSet/staticPool/dynamicPool)<br />- startDelay: milliseconds to wait at worker threads startup (only for workerSet threads process type)<br />- elementStartDelay: milliseconds to wait at charging station startup<br />- elementsPerWorker: number of charging stations per worker threads for the `workerSet` process type<br />- poolMinSize: worker threads pool minimum number of threads</br >- poolMaxSize: worker threads pool maximum number of threads<br />- poolStrategy: worker threads pool [poolifier](https://github.com/poolifier/poolifier) worker choice strategy |
a14885a3 114| uiServer | | {<br />"enabled": false,<br />"type": "ws",<br />"options": {<br />"host": "localhost",<br />"port": 8080<br />}<br />} | {<br />enabled: boolean;<br />type: ApplicationProtocol;<br />options: ServerOptions;<br />authentication: {<br />enabled: boolean;<br />type: AuthenticationType;<br />username: string;<br />password: string;<br />}<br />} | UI server configuration section |
19dbb570
JB
115| performanceStorage | | {<br />"enabled": false,<br />"type": "jsonfile",<br />"file:///performanceRecords.json"<br />} | {<br />enabled: boolean;<br />type: string;<br />URI: string;<br />}<br />where type can be 'jsonfile' or 'mongodb' | performance storage configuration section |
116| stationTemplateUrls | | {}[] | {<br />file: string;<br />numberOfStations: number;<br />}[] | array of charging station configuration templates URIs configuration section (charging station configuration template file name and number of stations) |
e7aeea18 117
d6b76da3 118#### Worker process model
a6b3c6c3
JB
119
120- **workerSet**:
4c6ed1d7 121 Worker set executing each a static number (elementsPerWorker) of simulated charging stations from the total
a6b3c6c3
JB
122
123- **staticPool**:
e7aeea18 124 Statically sized worker pool executing a static total number of simulated charging stations
a6b3c6c3
JB
125
126- **dynamicPool**:
e7aeea18 127 Dynamically sized worker pool executing a static total number of simulated charging stations
a6b3c6c3 128
1816f743
JB
129### Charging station configuration template
130
afccb423 131**src/assets/station-templates/\<name\>.json**:
1816f743 132
1d495af5
JB
133| Key | Value(s) | Default Value | Value type | Description |
134| ---------------------------------- | ------------- | ----------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
135| supervisionUrls | | [] | string \| string[] | string or array of connection URIs to OCPP-J servers |
136| supervisionUser | | undefined | string | basic HTTP authentication user to OCPP-J server |
137| supervisionPassword | | undefined | string | basic HTTP authentication password to OCPP-J server |
138| supervisionUrlOcppConfiguration | true/false | false | boolean | allow supervision URL configuration via a vendor OCPP parameter key |
139| supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL |
140| ocppVersion | 1.6/2.0/2.0.1 | 1.6 | string | OCPP version |
141| ocppProtocol | json | json | string | OCPP protocol |
142| ocppStrictCompliance | true/false | false | boolean | strict adherence to the OCPP version and protocol specifications |
143| ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
144| stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
145| wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection |
e302df1d 146| idTagsFile | | undefined | string | RFID tags list file relative to src/assets path |
1d495af5
JB
147| baseName | | undefined | string | base name to build charging stations id |
148| nameSuffix | | undefined | string | name suffix to build charging stations id |
149| fixedName | true/false | false | boolean | use the baseName as the charging stations unique name |
150| chargePointModel | | undefined | string | charging stations model |
151| chargePointVendor | | undefined | string | charging stations vendor |
152| chargePointSerialNumberPrefix | | undefined | string | charge point serial number prefix |
153| chargeBoxSerialNumberPrefix | | undefined | string | charge box serial number prefix (deprecated in OCPP 1.6) |
154| firmwareVersionPattern | | Semantic versionning regular expression: https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string | string | charging stations firmware version pattern |
155| firmwareVersion | | undefined | string | charging stations firmware version |
156| power | | | float \| float[] | charging stations maximum power value(s) |
157| powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors |
158| powerUnit | W/kW | W | string | charging stations power unit |
159| currentOutType | AC/DC | AC | string | charging stations current out type |
160| voltageOut | | AC:230/DC:400 | integer | charging stations voltage out |
161| numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) |
162| numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) |
163| useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template |
164| randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template |
165| resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset |
166| autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose |
167| autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server |
168| reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server |
169| registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries |
170| amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC |
171| amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit |
172| enableStatistics | true/false | false | boolean | enable charging stations statistics |
173| mustAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled |
174| payloadSchemaValidation | true/false | true | boolean | validate OCPP commands PDU against [OCA](https://www.openchargealliance.org/) JSON schemas |
175| beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues |
176| outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) |
177| meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis |
178| transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction |
179| mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations |
180| phaseLineToLineVoltageMeterValues | true/false | false | boolean | include charging stations line to line voltage MeterValues on three phased charging stations |
181| customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues |
182| firmwareUpgrade | | {<br />"versionUpgrade": {<br />"step": 1<br />},<br />"reset": true<br />} | {<br />versionUpgrade: {<br />patternGroup: number;<br />step: number;<br />};<br />reset: boolean;<br />failureStatus: 'DownloadFailed' \| 'InstallationFailed';<br />} | Configuration section for simulating firmware upgrade support. |
183| commandsSupport | | {<br />"incomingCommands": {},<br />"outgoingCommands": {}<br />} | {<br /> incomingCommands: Record<IncomingRequestCommand, boolean>;<br />outgoingCommands?: Record<RequestCommand, boolean>;<br />} | Configuration section for OCPP commands support. Empty section or subsections means all implemented OCPP commands are supported |
184| messageTriggerSupport | | {} | Record<MessageTrigger, boolean> | Configuration section for OCPP commands trigger support. Empty section means all implemented OCPP trigger commands are supported |
185| Configuration | | | ChargingStationConfiguration | charging stations OCPP parameters configuration section |
186| AutomaticTransactionGenerator | | | AutomaticTransactionGenerator | charging stations ATG configuration section |
187| Connectors | | | Connectors | charging stations connectors configuration section |
c94a349a
JB
188
189#### Configuration section
190
191```json
0302da79 192 "Configuration": {
c94a349a
JB
193 "configurationKey": [
194 ...
195 {
196 "key": "StandardKey",
197 "readonly": false,
198 "value": "StandardValue",
199 "visible": true,
200 "reboot": false
201 },
202 ...
203 {
204 "key": "VendorKey",
205 "readonly": false,
206 "value": "VendorValue",
207 "visible": false,
208 "reboot": true
209 },
210 ...
211 ]
212 }
213```
214
215#### AutomaticTransactionGenerator section
216
c72f6634
JB
217Section type definition:
218
219```ts
220type AutomaticTransactionGeneratorConfiguration = {
221 enable: boolean;
222 minDuration: number;
223 maxDuration: number;
224 minDelayBetweenTwoTransactions: number;
225 maxDelayBetweenTwoTransactions: number;
226 probabilityOfStart: number;
227 stopAfterHours: number;
228 stopOnConnectionFailure: boolean;
229 requireAuthorize?: boolean;
230 idTagDistribution?: 'random' | 'round-robin' | 'connector-affinity';
231};
232```
233
234Section example:
235
c94a349a 236```json
0302da79 237 "AutomaticTransactionGenerator": {
c94a349a
JB
238 "enable": false,
239 "minDuration": 60,
240 "maxDuration": 80,
241 "minDelayBetweenTwoTransactions": 15,
242 "maxDelayBetweenTwoTransactions": 30,
243 "probabilityOfStart": 1,
244 "stopAfterHours": 0.3,
245 "stopOnConnectionFailure": true,
c72f6634
JB
246 "requireAuthorize": true,
247 "idTagDistribution": "random"
c94a349a
JB
248 }
249```
e7aeea18 250
c94a349a
JB
251#### Connectors section
252
253```json
0302da79 254 "Connectors": {
c94a349a
JB
255 "0": {},
256 "1": {
257 "bootStatus": "Available",
258 "MeterValues": [
9bd87386
JB
259 ...
260 {
261 "unit": "W",
262 "measurand": "Power.Active.Import",
263 "phase": "L1-N",
264 "value": "5000",
265 "fluctuationPercent": "10"
266 },
c94a349a
JB
267 ...
268 {
269 "unit": "A",
860ef183
JB
270 "measurand": "Current.Import",
271 "minimum": "0.5"
c94a349a
JB
272 },
273 ...
274 {
275 "unit": "Wh"
276 },
277 ...
278 ]
279 }
280 },
281```
282
1816f743
JB
283### Charging station configuration
284
1c51fd1d 285**dist/assets/configurations/\<hashId\>.json**:
1816f743 286
a9ec2018 287The charging station configuration file is automatically generated at startup from the charging station configuration template file and is persistent.
1816f743
JB
288
289The charging station configuration file content can be regenerated partially on matching charging station configuration template file changes. The charging station serial number is kept unchanged.
290
291#### stationInfo section
292
293The syntax is similar to charging station configuration template with some added fields like the charging station id (name) and the 'Configuration' section removed.
294
295#### configurationKey section
296
297The syntax is similar to the charging station configuration template 'Configuration' section.
298
6f0ec20e
JB
299## Docker
300
301In the [docker](./docker) folder:
302
303```bash
304make
305```
306
bfcad885 307Or with the optional git submodules:
6f0ec20e
JB
308
309```bash
bfcad885 310make SUBMODULES_INIT=true
6f0ec20e
JB
311```
312
313## OCPP-J commands supported
c94a349a
JB
314
315### Version 1.6
316
c56d42f1 317#### Core Profile
6f0ec20e 318
778f7924
JB
319- :white_check_mark: Authorize
320- :white_check_mark: BootNotification
321- :white_check_mark: ChangeAvailability
322- :white_check_mark: ChangeConfiguration
323- :white_check_mark: ClearCache
91a7d3ea 324- :white_check_mark: DataTransfer
778f7924
JB
325- :white_check_mark: GetConfiguration
326- :white_check_mark: Heartbeat
327- :white_check_mark: MeterValues
328- :white_check_mark: RemoteStartTransaction
329- :white_check_mark: RemoteStopTransaction
330- :white_check_mark: Reset
331- :white_check_mark: StartTransaction
332- :white_check_mark: StatusNotification
333- :white_check_mark: StopTransaction
334- :white_check_mark: UnlockConnector
6f0ec20e 335
c56d42f1 336#### Firmware Management Profile
6f0ec20e 337
b652b0c3 338- :white_check_mark: GetDiagnostics
d50343bd 339- :white_check_mark: DiagnosticsStatusNotification
c9a4f9ea
JB
340- :white_check_mark: FirmwareStatusNotification
341- :white_check_mark: UpdateFirmware
6f0ec20e 342
c56d42f1 343#### Local Auth List Management Profile
6f0ec20e 344
9e1b12e4
JB
345- :x: GetLocalListVersion
346- :x: SendLocalList
6f0ec20e 347
c56d42f1 348#### Reservation Profile
6f0ec20e 349
9e1b12e4
JB
350- :x: CancelReservation
351- :x: ReserveNow
6f0ec20e 352
c56d42f1 353#### Smart Charging Profile
6f0ec20e 354
778f7924 355- :white_check_mark: ClearChargingProfile
68cb8b91 356- :x: GetCompositeSchedule
778f7924 357- :white_check_mark: SetChargingProfile
6f0ec20e 358
c56d42f1 359#### Remote Trigger Profile
6f0ec20e 360
802cfa13 361- :white_check_mark: TriggerMessage
7dde0b73 362
7e1dc878
JB
363## OCPP-J standard parameters supported
364
1816f743 365All kind of OCPP parameters are supported in a charging station configuration or a charging station configuration template file. The list here mention the standard ones also handled automatically in the simulator.
7e1dc878
JB
366
367### Version 1.6
368
c56d42f1 369#### Core Profile
7e1dc878
JB
370
371- :white_check_mark: AuthorizeRemoteTxRequests (type: boolean) (units: -)
372- :x: ClockAlignedDataInterval (type: integer) (units: seconds)
291cb255 373- :white_check_mark: ConnectionTimeOut (type: integer) (units: seconds)
7e1dc878
JB
374- :x: GetConfigurationMaxKeys (type: integer) (units: -)
375- :white_check_mark: HeartbeatInterval (type: integer) (units: seconds)
376- :x: LocalAuthorizeOffline (type: boolean) (units: -)
377- :x: LocalPreAuthorize (type: boolean) (units: -)
378- :x: MeterValuesAlignedData (type: CSL) (units: -)
379- :white_check_mark: MeterValuesSampledData (type: CSL) (units: -)
380- :white_check_mark: MeterValueSampleInterval (type: integer) (units: seconds)
381- :white_check_mark: NumberOfConnectors (type: integer) (units: -)
382- :x: ResetRetries (type: integer) (units: times)
383- :white_check_mark: ConnectorPhaseRotation (type: CSL) (units: -)
384- :x: StopTransactionOnEVSideDisconnect (type: boolean) (units: -)
385- :x: StopTransactionOnInvalidId (type: boolean) (units: -)
386- :x: StopTxnAlignedData (type: CSL) (units: -)
387- :x: StopTxnSampledData (type: CSL) (units: -)
36f6a92e 388- :white_check_mark: SupportedFeatureProfiles (type: CSL) (units: -)
7e1dc878
JB
389- :x: TransactionMessageAttempts (type: integer) (units: times)
390- :x: TransactionMessageRetryInterval (type: integer) (units: seconds)
391- :x: UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -)
36f6a92e 392- :white_check_mark: WebSocketPingInterval (type: integer) (units: seconds)
7e1dc878 393
c56d42f1 394#### Firmware Management Profile
7e1dc878 395
e7aeea18 396- _none_
7e1dc878 397
c56d42f1 398#### Local Auth List Management Profile
7e1dc878 399
36f6a92e 400- :white_check_mark: LocalAuthListEnabled (type: boolean) (units: -)
7e1dc878
JB
401- :x: LocalAuthListMaxLength (type: integer) (units: -)
402- :x: SendLocalListMaxLength (type: integer) (units: -)
403
c56d42f1 404#### Reservation Profile
7e1dc878 405
e7aeea18 406- _none_
7e1dc878 407
c56d42f1 408#### Smart Charging Profile
7e1dc878
JB
409
410- :x: ChargeProfileMaxStackLevel (type: integer) (units: -)
411- :x: ChargingScheduleAllowedChargingRateUnit (type: CSL) (units: -)
412- :x: ChargingScheduleMaxPeriods (type: integer) (units: -)
413- :x: MaxChargingProfilesInstalled (type: integer) (units: -)
414
c56d42f1 415#### Remote Trigger Profile
7e1dc878 416
e7aeea18 417- _none_
7e1dc878 418
32de5a57
LM
419## UI protocol
420
03ebf4c1 421Protocol to control the simulator via a Websocket or HTTP server.
32de5a57 422
4df14d3a
JB
423### HTTP Protocol
424
97c19696 425To learn how to use the HTTP protocol to pilot the simulator, an [Insomnia](https://insomnia.rest/) HTTP requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory.
4df14d3a 426
02cde3b7 427### Websocket Protocol
32de5a57 428
02cde3b7 429SRPC protocol over Websocket. PDU stands for 'Protocol Data Unit'.
32de5a57 430
03ebf4c1
JB
431- Request:
432 [`uuid`, `ProcedureName`, `PDU`]
433 `uuid`: String uniquely representing this request
434 `ProcedureName`: The procedure to run on the simulator
435 `PDU`: The parameters for said procedure
32de5a57 436
03ebf4c1
JB
437- Response:
438 [`uuid`, `PDU`]
439 `uuid`: String uniquely linking the response to the request
02cde3b7 440 `PDU`: Response parameters to requested procedure
32de5a57 441
97c19696
JB
442An [Insomnia](https://insomnia.rest/) WebSocket requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory.
443
d3140adc 444#### Version 0.0.1
4e3ff94d 445
02cde3b7 446Set the Websocket header _Sec-Websocket-Protocol_ to `ui0.0.1`.
4e3ff94d 447
d3140adc 448##### Procedures
32de5a57 449
d3140adc 450###### Start Simulator
5612b691 451
03ebf4c1
JB
452- Request:
453 `ProcedureName`: 'startSimulator'
454 `PDU`: {}
5612b691 455
03ebf4c1
JB
456- Response:
457 `PDU`: {
853ed24a 458 `status`: 'success' | 'failure'
03ebf4c1 459 }
5612b691 460
d3140adc 461###### Stop Simulator
5612b691 462
03ebf4c1
JB
463- Request:
464 `ProcedureName`: 'stopSimulator'
465 `PDU`: {}
5612b691 466
03ebf4c1
JB
467- Response:
468 `PDU`: {
853ed24a 469 `status`: 'success' | 'failure'
03ebf4c1 470 }
5612b691 471
d3140adc 472###### List Charging Stations
32de5a57 473
03ebf4c1
JB
474- Request:
475 `ProcedureName`: 'listChargingStations'
476 `PDU`: {}
32de5a57 477
03ebf4c1
JB
478- Response:
479 `PDU`: {
853ed24a 480 `status`: 'success' | 'failure',
02cde3b7 481 `chargingStations`: ChargingStationData[]
03ebf4c1 482 }
32de5a57 483
d3140adc 484###### Start Charging Station
80a3704c 485
03ebf4c1
JB
486- Request:
487 `ProcedureName`: 'startChargingStation'
488 `PDU`: {
03eee93b 489 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
03ebf4c1 490 }
80a3704c 491
03ebf4c1
JB
492- Response:
493 `PDU`: {
853ed24a
JB
494 `status`: 'success' | 'failure',
495 `hashIdsSucceeded`: charging station unique identifier strings array,
496 `hashIdsFailed`: charging station unique identifier strings array (optional)
03eee93b 497 `responsesFailed`: failed responses payload array (optional)
03ebf4c1 498 }
80a3704c 499
d3140adc 500###### Stop Charging Station
80a3704c 501
03ebf4c1
JB
502- Request:
503 `ProcedureName`: 'stopChargingStation'
504 `PDU`: {
853ed24a 505 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
03ebf4c1 506 }
80a3704c 507
03ebf4c1
JB
508- Response:
509 `PDU`: {
853ed24a
JB
510 `status`: 'success' | 'failure',
511 `hashIdsSucceeded`: charging station unique identifier strings array,
94abe068
JB
512 `hashIdsFailed`: charging station unique identifier strings array (optional),
513 `responsesFailed`: failed responses payload array (optional)
03ebf4c1 514 }
80a3704c 515
d3140adc 516###### Open Connection
e4df816e 517
03ebf4c1
JB
518- Request:
519 `ProcedureName`: 'openConnection'
520 `PDU`: {
853ed24a 521 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
03ebf4c1 522 }
e4df816e 523
03ebf4c1
JB
524- Response:
525 `PDU`: {
853ed24a
JB
526 `status`: 'success' | 'failure',
527 `hashIdsSucceeded`: charging station unique identifier strings array,
94abe068
JB
528 `hashIdsFailed`: charging station unique identifier strings array (optional),
529 `responsesFailed`: failed responses payload array (optional)
03ebf4c1 530 }
e4df816e 531
d3140adc 532###### Close Connection
e4df816e 533
03ebf4c1
JB
534- Request:
535 `ProcedureName`: 'closeConnection'
536 `PDU`: {
853ed24a 537 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
03ebf4c1
JB
538 }
539
540- Response:
541 `PDU`: {
853ed24a
JB
542 `status`: 'success' | 'failure',
543 `hashIdsSucceeded`: charging station unique identifier strings array,
94abe068
JB
544 `hashIdsFailed`: charging station unique identifier strings array (optional),
545 `responsesFailed`: failed responses payload array (optional)
853ed24a
JB
546 }
547
548###### Start Automatic Transaction Generator
549
550- Request:
551 `ProcedureName`: 'startAutomaticTransactionGenerator'
552 `PDU`: {
553 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
a38bc315 554 `connectorIds`: connector id integer array (optional, default: all connectors)
853ed24a
JB
555 }
556
557- Response:
558 `PDU`: {
559 `status`: 'success' | 'failure',
560 `hashIdsSucceeded`: charging station unique identifier strings array,
5566ca3e
JB
561 `hashIdsFailed`: charging station unique identifier strings array (optional),
562 `responsesFailed`: failed responses payload array (optional)
853ed24a
JB
563 }
564
565###### Stop Automatic Transaction Generator
566
567- Request:
568 `ProcedureName`: 'stopAutomaticTransactionGenerator'
569 `PDU`: {
570 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
a38bc315 571 `connectorIds`: connector id integer array (optional, default: all connectors)
853ed24a
JB
572 }
573
574- Response:
575 `PDU`: {
576 `status`: 'success' | 'failure',
577 `hashIdsSucceeded`: charging station unique identifier strings array,
5566ca3e
JB
578 `hashIdsFailed`: charging station unique identifier strings array (optional),
579 `responsesFailed`: failed responses payload array (optional)
03ebf4c1
JB
580 }
581
91a7d3ea 582###### OCPP commands trigger
a9ed42b2 583
82cbef8d
JB
584- Request:
585 `ProcedureName`: 'commandName' (the OCPP command name in camel case)
586 `PDU`: {
587 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
588 ...`commandPayload`
589 } (the OCPP command payload with some optional fields added to target the simulated charging stations)
10db00b2 590
82cbef8d
JB
591- Response:
592 `PDU`: {
593 `status`: 'success' | 'failure',
594 `hashIdsSucceeded`: charging station unique identifier strings array,
595 `hashIdsFailed`: charging station unique identifier strings array (optional),
596 `responsesFailed`: failed responses payload array (optional)
597 }
10db00b2 598
91a7d3ea 599Examples:
10db00b2 600
91a7d3ea 601- **Start Transaction**
a9ed42b2 602
91a7d3ea
JB
603 - Request:
604 `ProcedureName`: 'startTransaction'
605 `PDU`: {
606 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
607 `connectorId`: connector id integer,
608 `idTag`: RFID tag string
609 }
610
611 - Response:
612 `PDU`: {
613 `status`: 'success' | 'failure',
614 `hashIdsSucceeded`: charging station unique identifier strings array,
615 `hashIdsFailed`: charging station unique identifier strings array (optional),
616 `responsesFailed`: failed responses payload array (optional)
617 }
618
619- **Stop Transaction**
620
621 - Request:
622 `ProcedureName`: 'stopTransaction'
623 `PDU`: {
624 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
625 `transactionId`: transaction id integer
626 }
627
628 - Response:
629 `PDU`: {
630 `status`: 'success' | 'failure',
631 `hashIdsSucceeded`: charging station unique identifier strings array,
632 `hashIdsFailed`: charging station unique identifier strings array (optional),
633 `responsesFailed`: failed responses payload array (optional)
634 }
635
636- **Status Notification**
637
638 - Request:
82cbef8d 639 `ProcedureName`: 'statusNotification'
91a7d3ea
JB
640 `PDU`: {
641 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
642 `connectorId`: connector id integer,
643 `errorCode`: connector error code,
644 `status`: connector status
645 }
646
647 - Response:
648 `PDU`: {
649 `status`: 'success' | 'failure',
650 `hashIdsSucceeded`: charging station unique identifier strings array,
651 `hashIdsFailed`: charging station unique identifier strings array (optional),
652 `responsesFailed`: failed responses payload array (optional)
653 }
654
655- **Heartbeat**
656
657 - Request:
82cbef8d 658 `ProcedureName`: 'heartbeat'
91a7d3ea
JB
659 `PDU`: {
660 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
661 }
662
663 - Response:
664 `PDU`: {
665 `status`: 'success' | 'failure',
666 `hashIdsSucceeded`: charging station unique identifier strings array,
667 `hashIdsFailed`: charging station unique identifier strings array (optional),
668 `responsesFailed`: failed responses payload array (optional)
669 }
a9ed42b2 670
251fff5c 671## Support, Feedback, Contributing
7dde0b73 672
7f774a55 673This project is open to feature requests/suggestions, bug reports etc. via [GitHub issues](https://github.com/SAP/e-mobility-charging-stations-simulator/issues). Contribution and feedback are encouraged and always welcome. For more information about how to contribute, the project structure, as well as additional contribution information, see our [Contribution Guidelines](CONTRIBUTING.md).
7dde0b73 674
251fff5c
JB
675## Code of Conduct
676
677We as members, contributors, and leaders pledge to make participation in our community a harassment-free experience for everyone. By participating in this project, you agree to abide by its [Code of Conduct](CODE_OF_CONDUCT.md) at all times.
678
679## Licensing
680
a6609c86 681Copyright 2020-2023 SAP SE or an SAP affiliate company and e-mobility-charging-stations-simulator contributors. Please see our [LICENSE](LICENSE) for copyright and license information. Detailed information including third-party components and their licensing/copyright information is available [via the REUSE tool](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator).