refactor: remove payloadSchemaValidation from template in favor of ocppStrictCompliance
[e-mobility-charging-stations-simulator.git] / README.md
1 <!-- markdownlint-disable-file MD033 MD024 -->
2
3 # [e-mobility charging stations simulator](https://github.com/sap/e-mobility-charging-stations-simulator)
4
5 [![CI worklow](https://github.com/SAP/e-mobility-charging-stations-simulator/actions/workflows/ci.yml/badge.svg)](https://github.com/SAP/e-mobility-charging-stations-simulator/actions/workflows/ci.yml)
6 [![REUSE status](https://api.reuse.software/badge/github.com/SAP/e-mobility-charging-stations-simulator)](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator)
7
8 ## Summary
9
10 Simple [node.js](https://nodejs.org/) software to simulate and scale a set of charging stations based on the OCPP-J protocol as part of [SAP e-Mobility](https://www.sap.com/products/scm/e-mobility.html) solution.
11
12 ## Prerequisites
13
14 Install the [node.js](https://nodejs.org/) current LTS or superior version runtime environment:
15
16 ### Windows
17
18 - [Chocolatey](https://chocolatey.org/):
19
20 ```powershell
21 choco install -y nodejs
22 ```
23
24 ### MacOSX
25
26 - [Homebrew](https://brew.sh/):
27
28 ```shell
29 brew install node
30 ```
31
32 ### GNU/Linux
33
34 - [NodeSource](https://github.com/nodesource/distributions) Node.js Binary Distributions for version >= 16.X
35
36 ## Installation
37
38 Enable corepack if not already done and install latest pnpm version:
39
40 ```shell
41 corepack enable
42 corepack prepare pnpm@latest --activate
43 ```
44
45 In the repository root, run the following command:
46
47 ```shell
48 pnpm install
49 ```
50
51 ## Initial configuration
52
53 Copy the configuration template file [src/assets/config-template.json](src/assets/config-template.json) to [src/assets/config.json](src/assets/config.json).
54 Copy the RFID tags template file [src/assets/idtags-template.json](src/assets/idtags-template.json) to [src/assets/idtags.json](src/assets/idtags.json).
55
56 Tweak them to your needs by following the section [configuration files syntax](README.md#configuration-files-syntax): OCPP server supervision URL(s), charging station templates, etc.
57
58 ## Start
59
60 To start the program, run: `pnpm start`.
61
62 ## Start Web UI
63
64 See Web UI [README.md](ui/web/README.md) for more information.
65
66 ## Configuration files syntax
67
68 All configuration files are in the JSON standard format.
69
70 **Configuration files locations**:
71
72 - charging stations simulator configuration: [src/assets/config.json](src/assets/config.json);
73 - charging station configuration templates: [src/assets/station-templates](src/assets/station-templates);
74 - charging station configurations: [dist/assets/configurations](dist/assets/configurations);
75 - charging station RFID tags lists: [src/assets](src/assets).
76
77 The charging stations simulator's configuration parameters must be within the `src/assets/config.json` file. A charging station simulator configuration template file is available at [src/assets/config-template.json](src/assets/config-template.json).
78
79 All charging station configuration templates are in the directory [src/assets/station-templates](src/assets/station-templates).
80
81 A list of RFID tags must be defined for the automatic transaction generator in a file with the default location and name: `src/assets/idtags.json`. A template file is available at [src/assets/idtags-template.json](src/assets/idtags-template.json).
82
83 **Configuration files hierarchy and priority**:
84
85 1. charging station configuration: [dist/assets/configurations](dist/assets/configurations);
86 2. charging station configuration template: [src/assets/station-templates](src/assets/station-templates);
87 3. charging stations simulator configuration: [src/assets/config.json](src/assets/config.json).
88
89 The charging stations simulator has an automatic configuration files reload feature at change for:
90
91 - charging stations simulator configuration;
92 - charging station configuration templates;
93 - charging station authorization RFID tags lists.
94
95 But the modifications to test have to be done to the files in the build target directory [dist/assets](dist/assets). Once the modifications are done, they have to be reported to the matching files in the build source directory [src/assets](src/assets) to ensure they will be taken into account at next build.
96
97 ### Charging stations simulator configuration
98
99 **src/assets/config.json**:
100
101 | Key | Value(s) | Default Value | Value type | Description |
102 | -------------------------- | -------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
103 | supervisionUrls | | [] | string \| string[] | string or strings array containing global connection URIs to OCPP-J servers |
104 | supervisionUrlDistribution | round-robin/random/charging-station-affinity | charging-station-affinity | string | supervision urls distribution policy to simulated charging stations |
105 | log | | {<br />"enabled": true,<br />"file": "logs/combined.log",<br />"errorFile": "logs/error.log",<br />"statisticsInterval": 60,<br />"level": "info",<br />"console": false,<br />"format": "simple",<br />"rotate": true<br />} | {<br />enabled: boolean;<br />file: string;<br />errorFile: string;<br />statisticsInterval: number;<br />level: string;<br />console: boolean;<br />format: string;<br />rotate: boolean;<br />maxFiles: string \| number;<br />maxSize: string \| number;<br />} | Log configuration section:<br />- _enabled_: enable logging<br />- _file_: log file relative path<br />- _errorFile_: error log file relative path<br />- _statisticsInterval_: seconds between charging stations statistics output in the logs<br />- _level_: emerg/alert/crit/error/warning/notice/info/debug [winston](https://github.com/winstonjs/winston) logging level</br >- _console_: output logs on the console<br />- _format_: [winston](https://github.com/winstonjs/winston) log format<br />- _rotate_: enable daily log files rotation<br />- _maxFiles_: maximum number of log files: https://github.com/winstonjs/winston-daily-rotate-file#options<br />- _maxSize_: maximum size of log files in bytes, or units of kb, mb, and gb: https://github.com/winstonjs/winston-daily-rotate-file#options |
106 | worker | | {<br />"processType": "workerSet",<br />"startDelay": 500,<br />"elementStartDelay": 0,<br />"elementsPerWorker": 1,<br />"poolMinSize": 4,<br />"poolMaxSize": 16,<br />"poolStrategy": "ROUND_ROBIN"<br />} | {<br />processType: WorkerProcessType;<br />startDelay: number;<br />elementStartDelay: number;<br />elementsPerWorker: number;<br />poolMinSize: number;<br />poolMaxSize: number;<br />poolStrategy: WorkerChoiceStrategy;<br />} | Worker configuration section:<br />- _processType_: worker threads process type (`workerSet`/`staticPool`/`dynamicPool`)<br />- _startDelay_: milliseconds to wait at worker threads startup (only for `workerSet` worker threads process type)<br />- _elementStartDelay_: milliseconds to wait at charging station startup<br />- _elementsPerWorker_: number of charging stations per worker threads for the `workerSet` process type<br />- _poolMinSize_: worker threads pool minimum number of threads</br >- _poolMaxSize_: worker threads pool maximum number of threads<br />- _poolStrategy_: worker threads pool [poolifier](https://github.com/poolifier/poolifier) worker choice strategy |
107 | uiServer | | {<br />"enabled": false,<br />"type": "ws",<br />"options": {<br />"host": "localhost",<br />"port": 8080<br />}<br />} | {<br />enabled: boolean;<br />type: ApplicationProtocol;<br />options: ServerOptions;<br />authentication: {<br />enabled: boolean;<br />type: AuthenticationType;<br />username: string;<br />password: string;<br />}<br />} | UI server configuration section |
108 | performanceStorage | | {<br />"enabled": false,<br />"type": "jsonfile",<br />"file:///performanceRecords.json"<br />} | {<br />enabled: boolean;<br />type: string;<br />URI: string;<br />}<br />where type can be 'jsonfile' or 'mongodb' | performance storage configuration section |
109 | stationTemplateUrls | | {}[] | {<br />file: string;<br />numberOfStations: number;<br />}[] | array of charging station configuration templates URIs configuration section (charging station configuration template file name and number of stations) |
110
111 #### Worker process model
112
113 - **workerSet**:
114 Worker set executing each a static number (elementsPerWorker) of simulated charging stations from the total
115
116 - **staticPool**:
117 Statically sized worker pool executing a static total number of simulated charging stations
118
119 - **dynamicPool**:
120 Dynamically sized worker pool executing a static total number of simulated charging stations
121
122 ### Charging station configuration template
123
124 **src/assets/station-templates/\<name\>.json**:
125
126 | Key | Value(s) | Default Value | Value type | Description |
127 | ---------------------------------------------------- | ------------- | ----------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
128 | supervisionUrls | | [] | string \| string[] | string or strings array containing connection URIs to OCPP-J servers |
129 | supervisionUser | | undefined | string | basic HTTP authentication user to OCPP-J server |
130 | supervisionPassword | | undefined | string | basic HTTP authentication password to OCPP-J server |
131 | supervisionUrlOcppConfiguration | true/false | false | boolean | allow supervision URL configuration via a vendor OCPP parameter key |
132 | supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL |
133 | ocppVersion | 1.6/2.0/2.0.1 | 1.6 | string | OCPP version |
134 | ocppProtocol | json | json | string | OCPP protocol |
135 | ocppStrictCompliance | true/false | false | boolean | strict adherence to the OCPP version and protocol specifications. OCPP commands PDU validation against [OCA](https://www.openchargealliance.org/) JSON schemas |
136 | ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
137 | stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
138 | automaticTransactionGeneratorPersistentConfiguration | true/false | true | boolean | enable persistent automatic transaction generator configuration storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
139 | wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection |
140 | idTagsFile | | undefined | string | RFID tags list file relative to [src/assets](src/assets) path |
141 | baseName | | undefined | string | base name to build charging stations id |
142 | nameSuffix | | undefined | string | name suffix to build charging stations id |
143 | fixedName | true/false | false | boolean | use the baseName as the charging stations unique name |
144 | chargePointModel | | undefined | string | charging stations model |
145 | chargePointVendor | | undefined | string | charging stations vendor |
146 | chargePointSerialNumberPrefix | | undefined | string | charge point serial number prefix |
147 | chargeBoxSerialNumberPrefix | | undefined | string | charge box serial number prefix (deprecated in OCPP 1.6) |
148 | firmwareVersionPattern | | Semantic versionning regular expression: https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string | string | charging stations firmware version pattern |
149 | firmwareVersion | | undefined | string | charging stations firmware version |
150 | power | | | float \| float[] | charging stations maximum power value(s) |
151 | powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors |
152 | powerUnit | W/kW | W | string | charging stations power unit |
153 | currentOutType | AC/DC | AC | string | charging stations current out type |
154 | voltageOut | | AC:230/DC:400 | integer | charging stations voltage out |
155 | numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) |
156 | numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) |
157 | useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template |
158 | randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template |
159 | resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset |
160 | autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose |
161 | autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server |
162 | reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server |
163 | registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries |
164 | amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC |
165 | amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit |
166 | enableStatistics | true/false | false | boolean | enable charging stations statistics |
167 | mustAuthorizeAtRemoteStart | true/false | true | boolean | always send authorize at remote start transaction when AuthorizeRemoteTxRequests is enabled |
168 | beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues |
169 | outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) |
170 | meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis |
171 | transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction |
172 | mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations |
173 | phaseLineToLineVoltageMeterValues | true/false | false | boolean | include charging stations line to line voltage MeterValues on three phased charging stations |
174 | customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues |
175 | firmwareUpgrade | | {<br />"versionUpgrade": {<br />"step": 1<br />},<br />"reset": true<br />} | {<br />versionUpgrade: {<br />patternGroup: number;<br />step: number;<br />};<br />reset: boolean;<br />failureStatus: 'DownloadFailed' \| 'InstallationFailed';<br />} | Configuration section for simulating firmware upgrade support. |
176 | commandsSupport | | {<br />"incomingCommands": {},<br />"outgoingCommands": {}<br />} | {<br /> incomingCommands: Record<IncomingRequestCommand, boolean>;<br />outgoingCommands?: Record<RequestCommand, boolean>;<br />} | Configuration section for OCPP commands support. Empty section or subsections means all implemented OCPP commands are supported |
177 | messageTriggerSupport | | {} | Record<MessageTrigger, boolean> | Configuration section for OCPP commands trigger support. Empty section means all implemented OCPP trigger commands are supported |
178 | Configuration | | | ChargingStationOcppConfiguration | charging stations OCPP parameters configuration section |
179 | AutomaticTransactionGenerator | | | AutomaticTransactionGeneratorConfiguration | charging stations ATG configuration section |
180 | Connectors | | | Record<string, ConnectorStatus> | charging stations connectors configuration section |
181 | Evses | | | Record<string, EvseTemplate> | charging stations EVSEs configuration section |
182
183 #### Configuration section syntax example
184
185 ```json
186 "Configuration": {
187 "configurationKey": [
188 ...
189 {
190 "key": "StandardKey",
191 "readonly": false,
192 "value": "StandardValue",
193 "visible": true,
194 "reboot": false
195 },
196 ...
197 {
198 "key": "VendorKey",
199 "readonly": false,
200 "value": "VendorValue",
201 "visible": false,
202 "reboot": true
203 },
204 ...
205 ]
206 }
207 ```
208
209 #### AutomaticTransactionGenerator section syntax example
210
211 ##### Type definition:
212
213 ```ts
214 type AutomaticTransactionGeneratorConfiguration = {
215 enable: boolean;
216 minDuration: number;
217 maxDuration: number;
218 minDelayBetweenTwoTransactions: number;
219 maxDelayBetweenTwoTransactions: number;
220 probabilityOfStart: number;
221 stopAfterHours: number;
222 stopOnConnectionFailure: boolean;
223 requireAuthorize?: boolean;
224 idTagDistribution?: 'random' | 'round-robin' | 'connector-affinity';
225 };
226 ```
227
228 ##### Example:
229
230 ```json
231 "AutomaticTransactionGenerator": {
232 "enable": false,
233 "minDuration": 60,
234 "maxDuration": 80,
235 "minDelayBetweenTwoTransactions": 15,
236 "maxDelayBetweenTwoTransactions": 30,
237 "probabilityOfStart": 1,
238 "stopAfterHours": 0.3,
239 "stopOnConnectionFailure": true,
240 "requireAuthorize": true,
241 "idTagDistribution": "random"
242 }
243 ```
244
245 #### Connectors section syntax example
246
247 ```json
248 "Connectors": {
249 "0": {},
250 "1": {
251 "bootStatus": "Available",
252 "MeterValues": [
253 ...
254 {
255 "unit": "W",
256 "measurand": "Power.Active.Import",
257 "phase": "L1-N",
258 "value": "5000",
259 "fluctuationPercent": "10"
260 },
261 ...
262 {
263 "unit": "A",
264 "measurand": "Current.Import",
265 "minimum": "0.5"
266 },
267 ...
268 {
269 "unit": "Wh"
270 },
271 ...
272 ]
273 }
274 },
275 ```
276
277 #### Evses section syntax example
278
279 ```json
280 "Evses": {
281 "0": {
282 "Connectors": {
283 "0": {}
284 }
285 },
286 "1": {
287 "Connectors": {
288 "1": {
289 "bootStatus": "Available",
290 "MeterValues": [
291 ...
292 {
293 "unit": "W",
294 "measurand": "Power.Active.Import",
295 "phase": "L1-N",
296 "value": "5000",
297 "fluctuationPercent": "10"
298 },
299 ...
300 {
301 "unit": "A",
302 "measurand": "Current.Import",
303 "minimum": "0.5"
304 },
305 ...
306 {
307 "unit": "Wh"
308 },
309 ...
310 ]
311 }
312 }
313 }
314 },
315 ```
316
317 ### Charging station configuration
318
319 **dist/assets/configurations/\<hashId\>.json**:
320
321 The charging station configuration file is automatically generated at startup from the charging station configuration template file and is persistent.
322
323 The charging station configuration file content can be regenerated partially on matching charging station configuration template file changes. The charging station serial number is kept unchanged.
324
325 #### stationInfo section
326
327 The syntax is similar to charging station configuration template with some added fields like the charging station id (name) and the 'Configuration' section removed.
328
329 #### configurationKey section
330
331 The syntax is similar to the charging station configuration template 'Configuration' section.
332
333 #### automaticTransactionGenerator section
334
335 The syntax is similar to the charging station configuration template 'AutomaticTransactionGenerator' section.
336
337 ## Docker
338
339 In the [docker](./docker) folder:
340
341 ```bash
342 make
343 ```
344
345 Or with the optional git submodules:
346
347 ```bash
348 make SUBMODULES_INIT=true
349 ```
350
351 ## OCPP-J commands supported
352
353 ### Version 1.6
354
355 #### Core Profile
356
357 - :white_check_mark: Authorize
358 - :white_check_mark: BootNotification
359 - :white_check_mark: ChangeAvailability
360 - :white_check_mark: ChangeConfiguration
361 - :white_check_mark: ClearCache
362 - :white_check_mark: DataTransfer
363 - :white_check_mark: GetConfiguration
364 - :white_check_mark: Heartbeat
365 - :white_check_mark: MeterValues
366 - :white_check_mark: RemoteStartTransaction
367 - :white_check_mark: RemoteStopTransaction
368 - :white_check_mark: Reset
369 - :white_check_mark: StartTransaction
370 - :white_check_mark: StatusNotification
371 - :white_check_mark: StopTransaction
372 - :white_check_mark: UnlockConnector
373
374 #### Firmware Management Profile
375
376 - :white_check_mark: GetDiagnostics
377 - :white_check_mark: DiagnosticsStatusNotification
378 - :white_check_mark: FirmwareStatusNotification
379 - :white_check_mark: UpdateFirmware
380
381 #### Local Auth List Management Profile
382
383 - :x: GetLocalListVersion
384 - :x: SendLocalList
385
386 #### Reservation Profile
387
388 - :white_check_mark: CancelReservation
389 - :white_check_mark: ReserveNow
390
391 #### Smart Charging Profile
392
393 - :white_check_mark: ClearChargingProfile
394 - :x: GetCompositeSchedule
395 - :white_check_mark: SetChargingProfile
396
397 #### Remote Trigger Profile
398
399 - :white_check_mark: TriggerMessage
400
401 ### Version 2.x.x
402
403 #### Provisioning
404
405 - :white_check_mark: BootNotification
406
407 #### Authorization
408
409 - :white_check_mark: ClearCache
410
411 #### Availability
412
413 - :white_check_mark: StatusNotification
414 - :white_check_mark: Heartbeat
415
416 ## OCPP-J standard parameters supported
417
418 All kind of OCPP parameters are supported in charging station configuration or charging station configuration template file. The list here mention the standard ones also handled automatically in the simulator.
419
420 ### Version 1.6
421
422 #### Core Profile
423
424 - :white_check_mark: AuthorizeRemoteTxRequests (type: boolean) (units: -)
425 - :x: ClockAlignedDataInterval (type: integer) (units: seconds)
426 - :white_check_mark: ConnectionTimeOut (type: integer) (units: seconds)
427 - :x: GetConfigurationMaxKeys (type: integer) (units: -)
428 - :white_check_mark: HeartbeatInterval (type: integer) (units: seconds)
429 - :x: LocalAuthorizeOffline (type: boolean) (units: -)
430 - :x: LocalPreAuthorize (type: boolean) (units: -)
431 - :x: MeterValuesAlignedData (type: CSL) (units: -)
432 - :white_check_mark: MeterValuesSampledData (type: CSL) (units: -)
433 - :white_check_mark: MeterValueSampleInterval (type: integer) (units: seconds)
434 - :white_check_mark: NumberOfConnectors (type: integer) (units: -)
435 - :x: ResetRetries (type: integer) (units: times)
436 - :white_check_mark: ConnectorPhaseRotation (type: CSL) (units: -)
437 - :x: StopTransactionOnEVSideDisconnect (type: boolean) (units: -)
438 - :x: StopTransactionOnInvalidId (type: boolean) (units: -)
439 - :x: StopTxnAlignedData (type: CSL) (units: -)
440 - :x: StopTxnSampledData (type: CSL) (units: -)
441 - :white_check_mark: SupportedFeatureProfiles (type: CSL) (units: -)
442 - :x: TransactionMessageAttempts (type: integer) (units: times)
443 - :x: TransactionMessageRetryInterval (type: integer) (units: seconds)
444 - :x: UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -)
445 - :white_check_mark: WebSocketPingInterval (type: integer) (units: seconds)
446
447 #### Firmware Management Profile
448
449 - _none_
450
451 #### Local Auth List Management Profile
452
453 - :white_check_mark: LocalAuthListEnabled (type: boolean) (units: -)
454 - :x: LocalAuthListMaxLength (type: integer) (units: -)
455 - :x: SendLocalListMaxLength (type: integer) (units: -)
456
457 #### Reservation Profile
458
459 - :white_check_mark: ReserveConnectorZeroSupported (type: boolean) (units: -)
460
461 #### Smart Charging Profile
462
463 - :x: ChargeProfileMaxStackLevel (type: integer) (units: -)
464 - :x: ChargingScheduleAllowedChargingRateUnit (type: CSL) (units: -)
465 - :x: ChargingScheduleMaxPeriods (type: integer) (units: -)
466 - :x: MaxChargingProfilesInstalled (type: integer) (units: -)
467
468 #### Remote Trigger Profile
469
470 - _none_
471
472 ### Version 2.x.x
473
474 ## UI protocol
475
476 Protocol to control the simulator via a Websocket or HTTP server.
477
478 ### HTTP Protocol
479
480 To learn how to use the HTTP protocol to pilot the simulator, an [Insomnia](https://insomnia.rest/) HTTP requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory.
481
482 ### Websocket Protocol
483
484 SRPC protocol over Websocket. PDU stands for 'Protocol Data Unit'.
485
486 - Request:
487 [`uuid`, `ProcedureName`, `PDU`]
488 `uuid`: String uniquely representing this request
489 `ProcedureName`: The procedure to run on the simulator
490 `PDU`: The parameters for said procedure
491
492 - Response:
493 [`uuid`, `PDU`]
494 `uuid`: String uniquely linking the response to the request
495 `PDU`: Response parameters to requested procedure
496
497 An [Insomnia](https://insomnia.rest/) WebSocket requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory.
498
499 #### Version 0.0.1
500
501 Set the Websocket header _Sec-Websocket-Protocol_ to `ui0.0.1`.
502
503 ##### Procedures
504
505 ###### Start Simulator
506
507 - Request:
508 `ProcedureName`: 'startSimulator'
509 `PDU`: {}
510
511 - Response:
512 `PDU`: {
513 `status`: 'success' | 'failure'
514 }
515
516 ###### Stop Simulator
517
518 - Request:
519 `ProcedureName`: 'stopSimulator'
520 `PDU`: {}
521
522 - Response:
523 `PDU`: {
524 `status`: 'success' | 'failure'
525 }
526
527 ###### List Charging Stations
528
529 - Request:
530 `ProcedureName`: 'listChargingStations'
531 `PDU`: {}
532
533 - Response:
534 `PDU`: {
535 `status`: 'success' | 'failure',
536 `chargingStations`: ChargingStationData[]
537 }
538
539 ###### Start Charging Station
540
541 - Request:
542 `ProcedureName`: 'startChargingStation'
543 `PDU`: {
544 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
545 }
546
547 - Response:
548 `PDU`: {
549 `status`: 'success' | 'failure',
550 `hashIdsSucceeded`: charging station unique identifier strings array,
551 `hashIdsFailed`: charging station unique identifier strings array (optional)
552 `responsesFailed`: failed responses payload array (optional)
553 }
554
555 ###### Stop Charging Station
556
557 - Request:
558 `ProcedureName`: 'stopChargingStation'
559 `PDU`: {
560 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
561 }
562
563 - Response:
564 `PDU`: {
565 `status`: 'success' | 'failure',
566 `hashIdsSucceeded`: charging station unique identifier strings array,
567 `hashIdsFailed`: charging station unique identifier strings array (optional),
568 `responsesFailed`: failed responses payload array (optional)
569 }
570
571 ###### Open Connection
572
573 - Request:
574 `ProcedureName`: 'openConnection'
575 `PDU`: {
576 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
577 }
578
579 - Response:
580 `PDU`: {
581 `status`: 'success' | 'failure',
582 `hashIdsSucceeded`: charging station unique identifier strings array,
583 `hashIdsFailed`: charging station unique identifier strings array (optional),
584 `responsesFailed`: failed responses payload array (optional)
585 }
586
587 ###### Close Connection
588
589 - Request:
590 `ProcedureName`: 'closeConnection'
591 `PDU`: {
592 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
593 }
594
595 - Response:
596 `PDU`: {
597 `status`: 'success' | 'failure',
598 `hashIdsSucceeded`: charging station unique identifier strings array,
599 `hashIdsFailed`: charging station unique identifier strings array (optional),
600 `responsesFailed`: failed responses payload array (optional)
601 }
602
603 ###### Start Automatic Transaction Generator
604
605 - Request:
606 `ProcedureName`: 'startAutomaticTransactionGenerator'
607 `PDU`: {
608 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
609 `connectorIds`: connector id integer array (optional, default: all connectors)
610 }
611
612 - Response:
613 `PDU`: {
614 `status`: 'success' | 'failure',
615 `hashIdsSucceeded`: charging station unique identifier strings array,
616 `hashIdsFailed`: charging station unique identifier strings array (optional),
617 `responsesFailed`: failed responses payload array (optional)
618 }
619
620 ###### Stop Automatic Transaction Generator
621
622 - Request:
623 `ProcedureName`: 'stopAutomaticTransactionGenerator'
624 `PDU`: {
625 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
626 `connectorIds`: connector id integer array (optional, default: all connectors)
627 }
628
629 - Response:
630 `PDU`: {
631 `status`: 'success' | 'failure',
632 `hashIdsSucceeded`: charging station unique identifier strings array,
633 `hashIdsFailed`: charging station unique identifier strings array (optional),
634 `responsesFailed`: failed responses payload array (optional)
635 }
636
637 ###### OCPP commands trigger
638
639 - Request:
640 `ProcedureName`: 'commandName' (the OCPP command name in camel case)
641 `PDU`: {
642 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
643 ...`commandPayload`
644 } (the OCPP command payload with some optional fields added to target the simulated charging stations)
645
646 - Response:
647 `PDU`: {
648 `status`: 'success' | 'failure',
649 `hashIdsSucceeded`: charging station unique identifier strings array,
650 `hashIdsFailed`: charging station unique identifier strings array (optional),
651 `responsesFailed`: failed responses payload array (optional)
652 }
653
654 Examples:
655
656 - **Start Transaction**
657
658 - Request:
659 `ProcedureName`: 'startTransaction'
660 `PDU`: {
661 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
662 `connectorId`: connector id integer,
663 `idTag`: RFID tag string
664 }
665
666 - Response:
667 `PDU`: {
668 `status`: 'success' | 'failure',
669 `hashIdsSucceeded`: charging station unique identifier strings array,
670 `hashIdsFailed`: charging station unique identifier strings array (optional),
671 `responsesFailed`: failed responses payload array (optional)
672 }
673
674 - **Stop Transaction**
675
676 - Request:
677 `ProcedureName`: 'stopTransaction'
678 `PDU`: {
679 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
680 `transactionId`: transaction id integer
681 }
682
683 - Response:
684 `PDU`: {
685 `status`: 'success' | 'failure',
686 `hashIdsSucceeded`: charging station unique identifier strings array,
687 `hashIdsFailed`: charging station unique identifier strings array (optional),
688 `responsesFailed`: failed responses payload array (optional)
689 }
690
691 - **Status Notification**
692
693 - Request:
694 `ProcedureName`: 'statusNotification'
695 `PDU`: {
696 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
697 `connectorId`: connector id integer,
698 `errorCode`: connector error code,
699 `status`: connector status
700 }
701
702 - Response:
703 `PDU`: {
704 `status`: 'success' | 'failure',
705 `hashIdsSucceeded`: charging station unique identifier strings array,
706 `hashIdsFailed`: charging station unique identifier strings array (optional),
707 `responsesFailed`: failed responses payload array (optional)
708 }
709
710 - **Heartbeat**
711
712 - Request:
713 `ProcedureName`: 'heartbeat'
714 `PDU`: {
715 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
716 }
717
718 - Response:
719 `PDU`: {
720 `status`: 'success' | 'failure',
721 `hashIdsSucceeded`: charging station unique identifier strings array,
722 `hashIdsFailed`: charging station unique identifier strings array (optional),
723 `responsesFailed`: failed responses payload array (optional)
724 }
725
726 ## Support, Feedback, Contributing
727
728 This project is open to feature requests/suggestions, bug reports etc. via [GitHub issues](https://github.com/SAP/e-mobility-charging-stations-simulator/issues). Contribution and feedback are encouraged and always welcome. For more information about how to contribute, the project structure, as well as additional contribution information, see our [Contribution Guidelines](CONTRIBUTING.md).
729
730 ## Code of Conduct
731
732 We as members, contributors, and leaders pledge to make participation in our community a harassment-free experience for everyone. By participating in this project, you agree to abide by its [Code of Conduct](CODE_OF_CONDUCT.md) at all times.
733
734 ## Licensing
735
736 Copyright 2020-2023 SAP SE or an SAP affiliate company and e-mobility-charging-stations-simulator contributors. Please see our [LICENSE](LICENSE) for copyright and license information. Detailed information including third-party components and their licensing/copyright information is available [via the REUSE tool](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator).