refactor: code formatting fixlets
[e-mobility-charging-stations-simulator.git] / README.md
1 <!-- markdownlint-disable-file MD033 MD024 -->
2
3 # [e-mobility charging stations simulator](https://github.com/sap/e-mobility-charging-stations-simulator)
4
5 [![GitHub Clones](https://img.shields.io/badge/dynamic/json?color=brightgreen&label=Clone&query=count&url=https://gist.githubusercontent.com/jerome-benoit/c7c669b881d5b27dc0b44a639504ff93/raw/clone.json&logo=github)](https://github.com/SAP/e-mobility-charging-stations-simulator/graphs/traffic)
6 [![GitHub commit activity (main)](https://img.shields.io/github/commit-activity/m/SAP/e-mobility-charging-stations-simulator/main?color=brightgreen&logo=github)](https://github.com/SAP/e-mobility-charging-stations-simulator/graphs/commit-activity)
7 [![CI workflow](https://github.com/SAP/e-mobility-charging-stations-simulator/actions/workflows/ci.yml/badge.svg)](https://github.com/SAP/e-mobility-charging-stations-simulator/actions/workflows/ci.yml)
8 [![REUSE status](https://api.reuse.software/badge/github.com/SAP/e-mobility-charging-stations-simulator)](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator)
9 [![Javascript Standard Style Guide](<https://badgen.net/static/code style/standard/green>)](https://standardjs.com)
10
11 ## Summary
12
13 Simple [node.js](https://nodejs.org/) software to simulate and scale a set of charging stations based on the OCPP-J protocol as part of [SAP e-Mobility](https://www.sap.com/products/scm/e-mobility.html) solution.
14
15 ## Prerequisites
16
17 Install the [node.js](https://nodejs.org/) current LTS or superior version runtime environment:
18
19 ### Windows
20
21 - [Chocolatey](https://chocolatey.org/):
22
23 ```powershell
24 choco install -y nodejs
25 ```
26
27 ### MacOSX
28
29 - [Homebrew](https://brew.sh/):
30
31 ```shell
32 brew install node
33 ```
34
35 ### GNU/Linux
36
37 - [NodeSource](https://github.com/nodesource/distributions) Node.js Binary Distributions for all supported versions.
38
39 ## Installation
40
41 Enable corepack if not already done and install latest pnpm version:
42
43 ```shell
44 corepack enable
45 corepack prepare pnpm@latest --activate
46 ```
47
48 In the repository root, run the following command:
49
50 ```shell
51 pnpm install
52 ```
53
54 ## Initial configuration
55
56 Copy the configuration template file [src/assets/config-template.json](src/assets/config-template.json) to [src/assets/config.json](src/assets/config.json).
57 Copy the RFID tags template file [src/assets/idtags-template.json](src/assets/idtags-template.json) to [src/assets/idtags.json](src/assets/idtags.json).
58
59 Tweak them to your needs by following the section [configuration files syntax](README.md#configuration-files-syntax): OCPP server supervision URL(s), charging station templates, etc.
60
61 ## Start
62
63 To start the program, run: `pnpm start`.
64
65 ## Start Web UI
66
67 See Web UI [README.md](ui/web/README.md) for more information.
68
69 ## Configuration files syntax
70
71 All configuration files are in the JSON standard format.
72
73 **Configuration files locations**:
74
75 - charging stations simulator configuration: [src/assets/config.json](src/assets/config.json);
76 - charging station configuration templates: [src/assets/station-templates](src/assets/station-templates);
77 - charging station configurations: [dist/assets/configurations](dist/assets/configurations);
78 - charging station RFID tags lists: [src/assets](src/assets).
79
80 The charging stations simulator's configuration parameters must be within the `src/assets/config.json` file. A charging station simulator configuration template file is available at [src/assets/config-template.json](src/assets/config-template.json).
81
82 All charging station configuration templates are in the directory [src/assets/station-templates](src/assets/station-templates).
83
84 A list of RFID tags must be defined for the automatic transaction generator in a file with the default location and name: `src/assets/idtags.json`. A template file is available at [src/assets/idtags-template.json](src/assets/idtags-template.json).
85
86 **Configuration files hierarchy and priority**:
87
88 1. charging station configuration: [dist/assets/configurations](dist/assets/configurations);
89 2. charging station configuration template: [src/assets/station-templates](src/assets/station-templates);
90 3. charging stations simulator configuration: [src/assets/config.json](src/assets/config.json).
91
92 The charging stations simulator has an automatic configuration files reload feature at change for:
93
94 - charging stations simulator configuration;
95 - charging station configuration templates;
96 - charging station authorization RFID tags lists.
97
98 But the modifications to test have to be done to the files in the build target directory [dist/assets](dist/assets). Once the modifications are done, they have to be reported to the matching files in the build source directory [src/assets](src/assets) to ensure they will be taken into account at next build.
99
100 ### Charging stations simulator configuration
101
102 **src/assets/config.json**:
103
104 | Key | Value(s) | Default Value | Value type | Description |
105 | -------------------------- | -------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
106 | supervisionUrls | | [] | string \| string[] | string or strings array containing global connection URIs to OCPP-J servers |
107 | supervisionUrlDistribution | round-robin/random/charging-station-affinity | charging-station-affinity | string | supervision urls distribution policy to simulated charging stations |
108 | log | | {<br />"enabled": true,<br />"file": "logs/combined.log",<br />"errorFile": "logs/error.log",<br />"statisticsInterval": 60,<br />"level": "info",<br />"console": false,<br />"format": "simple",<br />"rotate": true<br />} | {<br />enabled?: boolean;<br />file?: string;<br />errorFile?: string;<br />statisticsInterval?: number;<br />level?: string;<br />console?: boolean;<br />format?: string;<br />rotate?: boolean;<br />maxFiles?: string \| number;<br />maxSize?: string \| number;<br />} | Log configuration section:<br />- _enabled_: enable logging<br />- _file_: log file relative path<br />- _errorFile_: error log file relative path<br />- _statisticsInterval_: seconds between charging stations statistics output in the logs<br />- _level_: emerg/alert/crit/error/warning/notice/info/debug [winston](https://github.com/winstonjs/winston) logging level</br >- _console_: output logs on the console<br />- _format_: [winston](https://github.com/winstonjs/winston) log format<br />- _rotate_: enable daily log files rotation<br />- _maxFiles_: maximum number of log files: https://github.com/winstonjs/winston-daily-rotate-file#options<br />- _maxSize_: maximum size of log files in bytes, or units of kb, mb, and gb: https://github.com/winstonjs/winston-daily-rotate-file#options |
109 | worker | | {<br />"processType": "workerSet",<br />"startDelay": 500,<br />"elementStartDelay": 0,<br />"elementsPerWorker": 'auto',<br />"poolMinSize": 4,<br />"poolMaxSize": 16<br />} | {<br />processType?: WorkerProcessType;<br />startDelay?: number;<br />elementStartDelay?: number;<br />elementsPerWorker?: number \| 'auto' \| 'all';<br />poolMinSize?: number;<br />poolMaxSize?: number;<br />resourceLimits?: ResourceLimits;<br />} | Worker configuration section:<br />- _processType_: worker threads process type (`workerSet`/`fixedPool`/`dynamicPool`)<br />- _startDelay_: milliseconds to wait at worker threads startup (only for `workerSet` worker threads process type)<br />- _elementStartDelay_: milliseconds to wait at charging station startup<br />- _elementsPerWorker_: number of charging stations per worker threads for the `workerSet` process type (`auto` means (number of stations) / (number of CPUs) \* 1.5 if (number of stations) > (number of CPUs), otherwise 1; `all` means a unique worker will run all charging stations)<br />- _poolMinSize_: worker threads pool minimum number of threads</br >- _poolMaxSize_: worker threads pool maximum number of threads<br />- _resourceLimits_: worker threads [resource limits](https://nodejs.org/api/worker_threads.html#new-workerfilename-options) object option |
110 | uiServer | | {<br />"enabled": false,<br />"type": "ws",<br />"version": "1.1",<br />"options": {<br />"host": "localhost",<br />"port": 8080<br />}<br />} | {<br />enabled?: boolean;<br />type?: ApplicationProtocol;<br />version?: ApplicationProtocolVersion;<br />options?: ServerOptions;<br />authentication?: {<br />enabled: boolean;<br />type: AuthenticationType;<br />username?: string;<br />password?: string;<br />}<br />} | UI server configuration section:<br />- _enabled_: enable UI server<br />- _type_: 'http' or 'ws'<br />- _version_: HTTP version '1.1' or '2.0'<br />- _options_: node.js net module [listen options](https://nodejs.org/api/net.html#serverlistenoptions-callback)<br />- _authentication_: authentication type configuration section |
111 | performanceStorage | | {<br />"enabled": true,<br />"type": "none",<br />} | {<br />enabled?: boolean;<br />type?: string;<br />uri?: string;<br />} | Performance storage configuration section:<br />- _enabled_: enable performance storage<br />- _type_: 'jsonfile', 'mongodb' or 'none'<br />- _uri_: storage URI |
112 | stationTemplateUrls | | {}[] | {<br />file: string;<br />numberOfStations: number;<br />}[] | array of charging station configuration templates URIs configuration section (charging station configuration template file name and number of stations) |
113
114 #### Worker process model
115
116 - **workerSet**:
117 Worker set executing each a fixed number (elementsPerWorker) of simulated charging stations from the total
118
119 - **fixedPool**:
120 Fixedly sized worker pool executing a fixed total number of simulated charging stations
121
122 - **dynamicPool** (experimental):
123 Dynamically sized worker pool executing a fixed total number of simulated charging stations
124
125 ### Charging station configuration template
126
127 **src/assets/station-templates/\<name\>.json**:
128
129 | Key | Value(s) | Default Value | Value type | Description |
130 | ---------------------------------------------------- | ------------- | ---------------------------------------------------------------------------------------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
131 | supervisionUrls | | [] | string \| string[] | string or strings array containing connection URIs to OCPP-J servers |
132 | supervisionUser | | undefined | string | basic HTTP authentication user to OCPP-J server |
133 | supervisionPassword | | undefined | string | basic HTTP authentication password to OCPP-J server |
134 | supervisionUrlOcppConfiguration | true/false | false | boolean | enable supervision URL configuration via a vendor OCPP parameter key |
135 | supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL |
136 | autoStart | true/false | true | boolean | enable automatic start of added charging station from template |
137 | ocppVersion | 1.6/2.0/2.0.1 | 1.6 | string | OCPP version |
138 | ocppProtocol | json | json | string | OCPP protocol |
139 | ocppStrictCompliance | true/false | true | boolean | enable strict adherence to the OCPP version and protocol specifications with OCPP commands PDU validation against [OCA](https://www.openchargealliance.org/) JSON schemas |
140 | ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
141 | stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
142 | automaticTransactionGeneratorPersistentConfiguration | true/false | true | boolean | enable persistent automatic transaction generator configuration storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
143 | wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection |
144 | idTagsFile | | undefined | string | RFID tags list file relative to [src/assets](src/assets) path |
145 | baseName | | undefined | string | base name to build charging stations id |
146 | nameSuffix | | undefined | string | name suffix to build charging stations id |
147 | fixedName | true/false | false | boolean | use the 'baseName' as the charging stations unique name |
148 | chargePointModel | | undefined | string | charging stations model |
149 | chargePointVendor | | undefined | string | charging stations vendor |
150 | chargePointSerialNumberPrefix | | undefined | string | charge point serial number prefix |
151 | chargeBoxSerialNumberPrefix | | undefined | string | charge box serial number prefix (deprecated since OCPP 1.6) |
152 | firmwareVersionPattern | | Semantic versioning regular expression: https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string | string | charging stations firmware version pattern |
153 | firmwareVersion | | undefined | string | charging stations firmware version |
154 | power | | | float \| float[] | charging stations maximum power value(s) |
155 | powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors |
156 | powerUnit | W/kW | W | string | charging stations power unit |
157 | currentOutType | AC/DC | AC | string | charging stations current out type |
158 | voltageOut | | AC:230/DC:400 | integer | charging stations voltage out |
159 | numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) |
160 | numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) |
161 | useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template |
162 | randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template |
163 | resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset |
164 | autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose |
165 | autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server |
166 | reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server |
167 | registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries |
168 | amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC |
169 | amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit |
170 | enableStatistics | true/false | false | boolean | enable charging stations statistics |
171 | remoteAuthorization | true/false | true | boolean | enable RFID tags remote authorization |
172 | beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues |
173 | outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) |
174 | meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis |
175 | transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction |
176 | stopTransactionsOnStopped | true/false | true | boolean | enable stop transactions on charging station stop |
177 | mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations |
178 | phaseLineToLineVoltageMeterValues | true/false | false | boolean | include charging stations line to line voltage MeterValues on three phased charging stations |
179 | customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues |
180 | firmwareUpgrade | | {<br />"versionUpgrade": {<br />"step": 1<br />},<br />"reset": true<br />} | {<br />versionUpgrade?: {<br />patternGroup?: number;<br />step?: number;<br />};<br />reset?: boolean;<br />failureStatus?: 'DownloadFailed' \| 'InstallationFailed';<br />} | Configuration section for simulating firmware upgrade support. |
181 | commandsSupport | | {<br />"incomingCommands": {},<br />"outgoingCommands": {}<br />} | {<br /> incomingCommands: Record<IncomingRequestCommand, boolean>;<br />outgoingCommands?: Record<RequestCommand, boolean>;<br />} | Configuration section for OCPP commands support. Empty section or subsections means all implemented OCPP commands are supported |
182 | messageTriggerSupport | | {} | Record<MessageTrigger, boolean> | Configuration section for OCPP commands trigger support. Empty section means all implemented OCPP trigger commands are supported |
183 | Configuration | | | ChargingStationOcppConfiguration | charging stations OCPP parameters configuration section |
184 | AutomaticTransactionGenerator | | | AutomaticTransactionGeneratorConfiguration | charging stations ATG configuration section |
185 | Connectors | | | Record<string, ConnectorStatus> | charging stations connectors configuration section |
186 | Evses | | | Record<string, EvseTemplate> | charging stations EVSEs configuration section |
187
188 #### Configuration section syntax example
189
190 ```json
191 "Configuration": {
192 "configurationKey": [
193 ...
194 {
195 "key": "StandardKey",
196 "readonly": false,
197 "value": "StandardValue",
198 "visible": true,
199 "reboot": false
200 },
201 ...
202 {
203 "key": "VendorKey",
204 "readonly": false,
205 "value": "VendorValue",
206 "visible": false,
207 "reboot": true
208 },
209 ...
210 ]
211 }
212 ```
213
214 #### AutomaticTransactionGenerator section syntax example
215
216 ##### Type definition:
217
218 ```ts
219 type AutomaticTransactionGeneratorConfiguration = {
220 enable: boolean
221 minDuration: number
222 maxDuration: number
223 minDelayBetweenTwoTransactions: number
224 maxDelayBetweenTwoTransactions: number
225 probabilityOfStart: number
226 stopAfterHours: number
227 stopAbsoluteDuration: boolean
228 requireAuthorize?: boolean
229 idTagDistribution?: 'random' | 'round-robin' | 'connector-affinity'
230 }
231 ```
232
233 ##### Example:
234
235 ```json
236 "AutomaticTransactionGenerator": {
237 "enable": false,
238 "minDuration": 60,
239 "maxDuration": 80,
240 "minDelayBetweenTwoTransactions": 15,
241 "maxDelayBetweenTwoTransactions": 30,
242 "probabilityOfStart": 1,
243 "stopAfterHours": 0.3,
244 "requireAuthorize": true,
245 "idTagDistribution": "random"
246 }
247 ```
248
249 #### Connectors section syntax example
250
251 ```json
252 "Connectors": {
253 "0": {},
254 "1": {
255 "bootStatus": "Available",
256 "MeterValues": [
257 ...
258 {
259 "unit": "W",
260 "measurand": "Power.Active.Import",
261 "phase": "L1-N",
262 "value": "5000",
263 "fluctuationPercent": "10"
264 },
265 ...
266 {
267 "unit": "A",
268 "measurand": "Current.Import",
269 "minimum": "0.5"
270 },
271 ...
272 {
273 "unit": "Wh"
274 },
275 ...
276 ]
277 }
278 },
279 ```
280
281 #### Evses section syntax example
282
283 ```json
284 "Evses": {
285 "0": {
286 "Connectors": {
287 "0": {}
288 }
289 },
290 "1": {
291 "Connectors": {
292 "1": {
293 "bootStatus": "Available",
294 "MeterValues": [
295 ...
296 {
297 "unit": "W",
298 "measurand": "Power.Active.Import",
299 "phase": "L1-N",
300 "value": "5000",
301 "fluctuationPercent": "10"
302 },
303 ...
304 {
305 "unit": "A",
306 "measurand": "Current.Import",
307 "minimum": "0.5"
308 },
309 ...
310 {
311 "unit": "Wh"
312 },
313 ...
314 ]
315 }
316 }
317 }
318 },
319 ```
320
321 ### Charging station configuration
322
323 **dist/assets/configurations/\<hashId\>.json**:
324
325 The charging station configuration file is automatically generated at startup from the charging station configuration template file and is persistent.
326
327 The charging station configuration file content can be regenerated partially on matching charging station configuration template file changes. The charging station serial number is kept unchanged.
328
329 #### stationInfo section (optional)
330
331 The syntax is similar to charging station configuration template with some added fields like the charging station id (name) and the 'Configuration' section removed.
332
333 That section is overwritten on matching charging station configuration template file changes.
334
335 #### connectorsStatus section
336
337 The syntax is similar to charging station configuration template 'Connectors' section with some added fields.
338
339 That section is overwritten on matching charging station configuration template file changes.
340
341 #### evsesStatus section
342
343 The syntax is similar to charging station configuration template 'Evses' section with some added fields.
344
345 That section is overwritten on matching charging station configuration template file changes.
346
347 #### automaticTransactionGenerator section (optional)
348
349 The syntax is similar to the charging station configuration template 'AutomaticTransactionGenerator' section.
350
351 That section is overwritten on matching charging station configuration template file changes.
352
353 #### automaticTransactionGeneratorStatuses section
354
355 That section is not overwritten on matching charging station configuration template file changes.
356
357 #### configurationKey section (optional)
358
359 The syntax is similar to the charging station configuration template 'Configuration' section.
360
361 That section is not overwritten on matching charging station configuration template file changes.
362
363 ## Docker
364
365 In the [docker](./docker) folder:
366
367 ```shell
368 make
369 ```
370
371 <!-- Or with the optional git submodules:
372
373 ```shell
374 make SUBMODULES_INIT=true
375 ``` -->
376
377 ## OCPP-J commands supported
378
379 ### Version 1.6
380
381 #### Core Profile
382
383 - :white_check_mark: Authorize
384 - :white_check_mark: BootNotification
385 - :white_check_mark: ChangeAvailability
386 - :white_check_mark: ChangeConfiguration
387 - :white_check_mark: ClearCache
388 - :white_check_mark: DataTransfer
389 - :white_check_mark: GetConfiguration
390 - :white_check_mark: Heartbeat
391 - :white_check_mark: MeterValues
392 - :white_check_mark: RemoteStartTransaction
393 - :white_check_mark: RemoteStopTransaction
394 - :white_check_mark: Reset
395 - :white_check_mark: StartTransaction
396 - :white_check_mark: StatusNotification
397 - :white_check_mark: StopTransaction
398 - :white_check_mark: UnlockConnector
399
400 #### Firmware Management Profile
401
402 - :white_check_mark: GetDiagnostics
403 - :white_check_mark: DiagnosticsStatusNotification
404 - :white_check_mark: FirmwareStatusNotification
405 - :white_check_mark: UpdateFirmware
406
407 #### Local Auth List Management Profile
408
409 - :x: GetLocalListVersion
410 - :x: SendLocalList
411
412 #### Reservation Profile
413
414 - :white_check_mark: CancelReservation
415 - :white_check_mark: ReserveNow
416
417 #### Smart Charging Profile
418
419 - :white_check_mark: ClearChargingProfile
420 - :white_check_mark: GetCompositeSchedule
421 - :white_check_mark: SetChargingProfile
422
423 #### Remote Trigger Profile
424
425 - :white_check_mark: TriggerMessage
426
427 ### Version 2.x.x
428
429 #### Provisioning
430
431 - :white_check_mark: BootNotification
432
433 #### Authorization
434
435 - :white_check_mark: ClearCache
436
437 #### Availability
438
439 - :white_check_mark: StatusNotification
440 - :white_check_mark: Heartbeat
441
442 ## OCPP-J standard parameters supported
443
444 All kind of OCPP parameters are supported in charging station configuration or charging station configuration template file. The list here mention the standard ones also handled automatically in the simulator.
445
446 ### Version 1.6
447
448 #### Core Profile
449
450 - :white_check_mark: AuthorizeRemoteTxRequests (type: boolean) (units: -)
451 - :x: ClockAlignedDataInterval (type: integer) (units: seconds)
452 - :white_check_mark: ConnectionTimeOut (type: integer) (units: seconds)
453 - :x: GetConfigurationMaxKeys (type: integer) (units: -)
454 - :white_check_mark: HeartbeatInterval (type: integer) (units: seconds)
455 - :x: LocalAuthorizeOffline (type: boolean) (units: -)
456 - :x: LocalPreAuthorize (type: boolean) (units: -)
457 - :x: MeterValuesAlignedData (type: CSL) (units: -)
458 - :white_check_mark: MeterValuesSampledData (type: CSL) (units: -)
459 - :white_check_mark: MeterValueSampleInterval (type: integer) (units: seconds)
460 - :white_check_mark: NumberOfConnectors (type: integer) (units: -)
461 - :x: ResetRetries (type: integer) (units: times)
462 - :white_check_mark: ConnectorPhaseRotation (type: CSL) (units: -)
463 - :x: StopTransactionOnEVSideDisconnect (type: boolean) (units: -)
464 - :x: StopTransactionOnInvalidId (type: boolean) (units: -)
465 - :x: StopTxnAlignedData (type: CSL) (units: -)
466 - :x: StopTxnSampledData (type: CSL) (units: -)
467 - :white_check_mark: SupportedFeatureProfiles (type: CSL) (units: -)
468 - :x: TransactionMessageAttempts (type: integer) (units: times)
469 - :x: TransactionMessageRetryInterval (type: integer) (units: seconds)
470 - :x: UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -)
471 - :white_check_mark: WebSocketPingInterval (type: integer) (units: seconds)
472
473 #### Firmware Management Profile
474
475 - _none_
476
477 #### Local Auth List Management Profile
478
479 - :white_check_mark: LocalAuthListEnabled (type: boolean) (units: -)
480 - :x: LocalAuthListMaxLength (type: integer) (units: -)
481 - :x: SendLocalListMaxLength (type: integer) (units: -)
482
483 #### Reservation Profile
484
485 - :white_check_mark: ReserveConnectorZeroSupported (type: boolean) (units: -)
486
487 #### Smart Charging Profile
488
489 - :x: ChargeProfileMaxStackLevel (type: integer) (units: -)
490 - :x: ChargingScheduleAllowedChargingRateUnit (type: CSL) (units: -)
491 - :x: ChargingScheduleMaxPeriods (type: integer) (units: -)
492 - :x: MaxChargingProfilesInstalled (type: integer) (units: -)
493
494 #### Remote Trigger Profile
495
496 - _none_
497
498 ### Version 2.x.x
499
500 ## UI protocol
501
502 Protocol to control the simulator via a Websocket or HTTP server:
503
504 ```mermaid
505 sequenceDiagram
506 Client->>UI Server: request
507 UI Server->>Client: response
508 Note over UI Server,Client: Transport protocol: HTTP, Websocket
509 ```
510
511 ### Websocket Protocol
512
513 SRPC protocol over Websocket. PDU stands for 'Protocol Data Unit'.
514
515 - Request:
516 [`uuid`, `ProcedureName`, `PDU`]
517 `uuid`: String uniquely representing this request
518 `ProcedureName`: The procedure to run on the simulator
519 `PDU`: The parameters for said procedure
520
521 - Response:
522 [`uuid`, `PDU`]
523 `uuid`: String uniquely linking the response to the request
524 `PDU`: Response parameters to requested procedure
525
526 To learn how to use the Websocket protocol to pilot the simulator, an [Insomnia](https://insomnia.rest/) Websocket requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory.
527
528 #### Version 0.0.1
529
530 Set the Websocket header _Sec-Websocket-Protocol_ to `ui0.0.1`.
531
532 ##### Procedures
533
534 ###### Start Simulator
535
536 - Request:
537 `ProcedureName`: 'startSimulator'
538 `PDU`: {}
539
540 - Response:
541 `PDU`: {
542 `status`: 'success' | 'failure'
543 }
544
545 ###### Stop Simulator
546
547 - Request:
548 `ProcedureName`: 'stopSimulator'
549 `PDU`: {}
550
551 - Response:
552 `PDU`: {
553 `status`: 'success' | 'failure'
554 }
555
556 ###### List Charging Station Templates
557
558 - Request:
559 `ProcedureName`: 'listTemplates'
560 `PDU`: {}
561
562 - Response:
563 `PDU`: {
564 `status`: 'success' | 'failure',
565 `templates`: string[]
566 }
567
568 ###### Add Charging Stations
569
570 - Request:
571 `ProcedureName`: 'addChargingStations'
572 `PDU`: {
573 `template`: string,
574 `numberOfStations`: number,
575 `options?`: {
576 `persistentConfiguration?`: boolean,
577 `autoStart?`: boolean,
578 `autoRegister?`: boolean
579 }
580 }
581
582 - Response:
583 `PDU`: {
584 `status`: 'success' | 'failure'
585 }
586
587 ###### Set Charging Station Supervision Url
588
589 - Request:
590 `ProcedureName`: 'setSupervisionUrl'
591 `PDU`: {
592 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
593 `url`: string
594 }
595
596 - Response:
597 `PDU`: {
598 `status`: 'success' | 'failure',
599 `hashIdsSucceeded`: charging station unique identifier strings array,
600 `hashIdsFailed`: charging station unique identifier strings array (optional),
601 `responsesFailed`: failed responses payload array (optional)
602 }
603
604 ###### Performance Statistics
605
606 - Request:
607 `ProcedureName`: 'performanceStatistics'
608 `PDU`: {}
609
610 - Response:
611 `PDU`: {
612 `status`: 'success' | 'failure'
613 `performanceStatistics`: Statistics[]
614 }
615
616 ###### List Charging Stations
617
618 - Request:
619 `ProcedureName`: 'listChargingStations'
620 `PDU`: {}
621
622 - Response:
623 `PDU`: {
624 `status`: 'success' | 'failure',
625 `chargingStations`: ChargingStationData[]
626 }
627
628 ###### Start Charging Station
629
630 - Request:
631 `ProcedureName`: 'startChargingStation'
632 `PDU`: {
633 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
634 }
635
636 - Response:
637 `PDU`: {
638 `status`: 'success' | 'failure',
639 `hashIdsSucceeded`: charging station unique identifier strings array,
640 `hashIdsFailed`: charging station unique identifier strings array (optional),
641 `responsesFailed`: failed responses payload array (optional)
642 }
643
644 ###### Stop Charging Station
645
646 - Request:
647 `ProcedureName`: 'stopChargingStation'
648 `PDU`: {
649 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
650 }
651
652 - Response:
653 `PDU`: {
654 `status`: 'success' | 'failure',
655 `hashIdsSucceeded`: charging station unique identifier strings array,
656 `hashIdsFailed`: charging station unique identifier strings array (optional),
657 `responsesFailed`: failed responses payload array (optional)
658 }
659
660 ###### Open Connection
661
662 - Request:
663 `ProcedureName`: 'openConnection'
664 `PDU`: {
665 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
666 }
667
668 - Response:
669 `PDU`: {
670 `status`: 'success' | 'failure',
671 `hashIdsSucceeded`: charging station unique identifier strings array,
672 `hashIdsFailed`: charging station unique identifier strings array (optional),
673 `responsesFailed`: failed responses payload array (optional)
674 }
675
676 ###### Close Connection
677
678 - Request:
679 `ProcedureName`: 'closeConnection'
680 `PDU`: {
681 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
682 }
683
684 - Response:
685 `PDU`: {
686 `status`: 'success' | 'failure',
687 `hashIdsSucceeded`: charging station unique identifier strings array,
688 `hashIdsFailed`: charging station unique identifier strings array (optional),
689 `responsesFailed`: failed responses payload array (optional)
690 }
691
692 ###### Start Automatic Transaction Generator
693
694 - Request:
695 `ProcedureName`: 'startAutomaticTransactionGenerator'
696 `PDU`: {
697 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
698 `connectorIds`: connector id integer array (optional, default: all connectors)
699 }
700
701 - Response:
702 `PDU`: {
703 `status`: 'success' | 'failure',
704 `hashIdsSucceeded`: charging station unique identifier strings array,
705 `hashIdsFailed`: charging station unique identifier strings array (optional),
706 `responsesFailed`: failed responses payload array (optional)
707 }
708
709 ###### Stop Automatic Transaction Generator
710
711 - Request:
712 `ProcedureName`: 'stopAutomaticTransactionGenerator'
713 `PDU`: {
714 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
715 `connectorIds`: connector id integer array (optional, default: all connectors)
716 }
717
718 - Response:
719 `PDU`: {
720 `status`: 'success' | 'failure',
721 `hashIdsSucceeded`: charging station unique identifier strings array,
722 `hashIdsFailed`: charging station unique identifier strings array (optional),
723 `responsesFailed`: failed responses payload array (optional)
724 }
725
726 ###### OCPP commands trigger
727
728 - Request:
729 `ProcedureName`: 'commandName' (the OCPP command name in camel case)
730 `PDU`: {
731 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
732 ...`commandPayload`
733 } (the OCPP command payload with some optional fields added to target the simulated charging stations)
734
735 - Response:
736 `PDU`: {
737 `status`: 'success' | 'failure',
738 `hashIdsSucceeded`: charging station unique identifier strings array,
739 `hashIdsFailed`: charging station unique identifier strings array (optional),
740 `responsesFailed`: failed responses payload array (optional)
741 }
742
743 Examples:
744
745 - **Start Transaction**
746
747 - Request:
748 `ProcedureName`: 'startTransaction'
749 `PDU`: {
750 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
751 `connectorId`: connector id integer,
752 `idTag`: RFID tag string
753 }
754
755 - Response:
756 `PDU`: {
757 `status`: 'success' | 'failure',
758 `hashIdsSucceeded`: charging station unique identifier strings array,
759 `hashIdsFailed`: charging station unique identifier strings array (optional),
760 `responsesFailed`: failed responses payload array (optional)
761 }
762
763 - **Stop Transaction**
764
765 - Request:
766 `ProcedureName`: 'stopTransaction'
767 `PDU`: {
768 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
769 `transactionId`: transaction id integer
770 }
771
772 - Response:
773 `PDU`: {
774 `status`: 'success' | 'failure',
775 `hashIdsSucceeded`: charging station unique identifier strings array,
776 `hashIdsFailed`: charging station unique identifier strings array (optional),
777 `responsesFailed`: failed responses payload array (optional)
778 }
779
780 - **Status Notification**
781
782 - Request:
783 `ProcedureName`: 'statusNotification'
784 `PDU`: {
785 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
786 `connectorId`: connector id integer,
787 `errorCode`: connector error code,
788 `status`: connector status
789 }
790
791 - Response:
792 `PDU`: {
793 `status`: 'success' | 'failure',
794 `hashIdsSucceeded`: charging station unique identifier strings array,
795 `hashIdsFailed`: charging station unique identifier strings array (optional),
796 `responsesFailed`: failed responses payload array (optional)
797 }
798
799 - **Heartbeat**
800
801 - Request:
802 `ProcedureName`: 'heartbeat'
803 `PDU`: {
804 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
805 }
806
807 - Response:
808 `PDU`: {
809 `status`: 'success' | 'failure',
810 `hashIdsSucceeded`: charging station unique identifier strings array,
811 `hashIdsFailed`: charging station unique identifier strings array (optional),
812 `responsesFailed`: failed responses payload array (optional)
813 }
814
815 ### HTTP Protocol
816
817 To learn how to use the HTTP protocol to pilot the simulator, an [Insomnia](https://insomnia.rest/) HTTP requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory.
818
819 ## Support, Feedback, Contributing
820
821 This project is open to feature requests/suggestions, bug reports etc. via [GitHub issues](https://github.com/SAP/e-mobility-charging-stations-simulator/issues). Contribution and feedback are encouraged and always welcome. For more information about how to contribute, the project structure, as well as additional contribution information, see our [Contribution Guidelines](CONTRIBUTING.md).
822
823 ## Code of Conduct
824
825 We as members, contributors, and leaders pledge to make participation in our community a harassment-free experience for everyone. By participating in this project, you agree to abide by its [Code of Conduct](CODE_OF_CONDUCT.md) at all times.
826
827 ## Licensing
828
829 Copyright 2020-2024 SAP SE or an SAP affiliate company and e-mobility-charging-stations-simulator contributors. Please see our [LICENSE](LICENSE) for copyright and license information. Detailed information including third-party components and their licensing/copyright information is available [via the REUSE tool](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator).