Merge pull request #724 from SAP/dependabot/github_actions/github/combine-prs-4.0.0
[e-mobility-charging-stations-simulator.git] / README.md
CommitLineData
d6b76da3 1<!-- markdownlint-disable-file MD033 MD024 -->
9e0845f7 2
1ea2264a 3# [e-mobility charging stations simulator](https://github.com/sap/e-mobility-charging-stations-simulator)
7dde0b73 4
d9bde576 5[![GitHub Clones](https://img.shields.io/badge/dynamic/json?color=success&label=Clone&query=count&url=https://gist.githubusercontent.com/jerome-benoit/c7c669b881d5b27dc0b44a639504ff93/raw/clone.json&logo=github)](https://github.com/SAP/e-mobility-charging-stations-simulator/graphs/traffic)
bd5ef8e8 6[![GitHub commit activity (main)](https://img.shields.io/github/commit-activity/m/SAP/e-mobility-charging-stations-simulator/main)](https://github.com/SAP/e-mobility-charging-stations-simulator/graphs/commit-activity)
f1fded7b 7[![CI workflow](https://github.com/SAP/e-mobility-charging-stations-simulator/actions/workflows/ci.yml/badge.svg)](https://github.com/SAP/e-mobility-charging-stations-simulator/actions/workflows/ci.yml)
4d188eb9 8[![REUSE status](https://api.reuse.software/badge/github.com/SAP/e-mobility-charging-stations-simulator)](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator)
0a3d08ef 9
7dde0b73
JB
10## Summary
11
a712de6f 12Simple [node.js](https://nodejs.org/) software to simulate and scale a set of charging stations based on the OCPP-J protocol as part of [SAP e-Mobility](https://www.sap.com/products/scm/e-mobility.html) solution.
7dde0b73 13
696ce53a
JB
14## Prerequisites
15
5845e83d 16Install the [node.js](https://nodejs.org/) current LTS or superior version runtime environment:
007ee642 17
696ce53a
JB
18### Windows
19
e7aeea18 20- [Chocolatey](https://chocolatey.org/):
696ce53a
JB
21
22```powershell
5845e83d 23choco install -y nodejs
696ce53a
JB
24```
25
26### MacOSX
27
e7aeea18 28- [Homebrew](https://brew.sh/):
696ce53a
JB
29
30```shell
5845e83d 31brew install node
696ce53a
JB
32```
33
d6b76da3 34### GNU/Linux
511780c3 35
eef659c1 36- [NodeSource](https://github.com/nodesource/distributions) Node.js Binary Distributions for all supported versions.
511780c3 37
007ee642
JB
38## Installation
39
1a662d29 40Enable corepack if not already done and install latest pnpm version:
5845e83d
JB
41
42```shell
43corepack enable
1a662d29 44corepack prepare pnpm@latest --activate
5845e83d
JB
45```
46
007ee642
JB
47In the repository root, run the following command:
48
49```shell
881f450c 50pnpm install
007ee642
JB
51```
52
53## Initial configuration
54
db70b600 55Copy the configuration template file [src/assets/config-template.json](src/assets/config-template.json) to [src/assets/config.json](src/assets/config.json).
e302df1d 56Copy the RFID tags template file [src/assets/idtags-template.json](src/assets/idtags-template.json) to [src/assets/idtags.json](src/assets/idtags.json).
db70b600 57
58b0ee76 58Tweak them to your needs by following the section [configuration files syntax](README.md#configuration-files-syntax): OCPP server supervision URL(s), charging station templates, etc.
007ee642
JB
59
60## Start
61
881f450c 62To start the program, run: `pnpm start`.
007ee642 63
4e3ff94d 64## Start Web UI
007ee642 65
ebbfbf1c 66See Web UI [README.md](ui/web/README.md) for more information.
b8cc885d 67
4d3821a2 68## Configuration files syntax
2c28fc83 69
e7aeea18 70All configuration files are in the JSON standard format.
2c28fc83 71
ff82dc5f 72**Configuration files locations**:
2c28fc83 73
170bec53 74- charging stations simulator configuration: [src/assets/config.json](src/assets/config.json);
1816f743 75- charging station configuration templates: [src/assets/station-templates](src/assets/station-templates);
1c51fd1d 76- charging station configurations: [dist/assets/configurations](dist/assets/configurations);
7f818162 77- charging station RFID tags lists: [src/assets](src/assets).
2c28fc83 78
1816f743
JB
79The charging stations simulator's configuration parameters must be within the `src/assets/config.json` file. A charging station simulator configuration template file is available at [src/assets/config-template.json](src/assets/config-template.json).
80
81All charging station configuration templates are in the directory [src/assets/station-templates](src/assets/station-templates).
82
3a28512c 83A list of RFID tags must be defined for the automatic transaction generator in a file with the default location and name: `src/assets/idtags.json`. A template file is available at [src/assets/idtags-template.json](src/assets/idtags-template.json).
1816f743
JB
84
85**Configuration files hierarchy and priority**:
86
1c51fd1d 871. charging station configuration: [dist/assets/configurations](dist/assets/configurations);
1816f743 882. charging station configuration template: [src/assets/station-templates](src/assets/station-templates);
170bec53 893. charging stations simulator configuration: [src/assets/config.json](src/assets/config.json).
511780c3 90
3a28512c 91The charging stations simulator has an automatic configuration files reload feature at change for:
511780c3 92
170bec53 93- charging stations simulator configuration;
1816f743 94- charging station configuration templates;
170bec53 95- charging station authorization RFID tags lists.
2c28fc83 96
3a28512c 97But the modifications to test have to be done to the files in the build target directory [dist/assets](dist/assets). Once the modifications are done, they have to be reported to the matching files in the build source directory [src/assets](src/assets) to ensure they will be taken into account at next build.
e7aeea18 98
170bec53 99### Charging stations simulator configuration
2c28fc83 100
b1d6e944 101**src/assets/config.json**:
2c28fc83 102
a6080904
JB
103| Key | Value(s) | Default Value | Value type | Description |
104| -------------------------- | -------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
105| supervisionUrls | | [] | string \| string[] | string or strings array containing global connection URIs to OCPP-J servers |
106| supervisionUrlDistribution | round-robin/random/charging-station-affinity | charging-station-affinity | string | supervision urls distribution policy to simulated charging stations |
107| log | | {<br />"enabled": true,<br />"file": "logs/combined.log",<br />"errorFile": "logs/error.log",<br />"statisticsInterval": 60,<br />"level": "info",<br />"console": false,<br />"format": "simple",<br />"rotate": true<br />} | {<br />enabled: boolean;<br />file: string;<br />errorFile: string;<br />statisticsInterval: number;<br />level: string;<br />console: boolean;<br />format: string;<br />rotate: boolean;<br />maxFiles: string \| number;<br />maxSize: string \| number;<br />} | Log configuration section:<br />- _enabled_: enable logging<br />- _file_: log file relative path<br />- _errorFile_: error log file relative path<br />- _statisticsInterval_: seconds between charging stations statistics output in the logs<br />- _level_: emerg/alert/crit/error/warning/notice/info/debug [winston](https://github.com/winstonjs/winston) logging level</br >- _console_: output logs on the console<br />- _format_: [winston](https://github.com/winstonjs/winston) log format<br />- _rotate_: enable daily log files rotation<br />- _maxFiles_: maximum number of log files: https://github.com/winstonjs/winston-daily-rotate-file#options<br />- _maxSize_: maximum size of log files in bytes, or units of kb, mb, and gb: https://github.com/winstonjs/winston-daily-rotate-file#options |
108| worker | | {<br />"processType": "workerSet",<br />"startDelay": 500,<br />"elementStartDelay": 0,<br />"elementsPerWorker": 'auto',<br />"poolMinSize": 4,<br />"poolMaxSize": 16<br />} | {<br />processType: WorkerProcessType;<br />startDelay: number;<br />elementStartDelay: number;<br />elementsPerWorker: number \| 'auto';<br />poolMinSize: number;<br />poolMaxSize: number;<br />} | Worker configuration section:<br />- _processType_: worker threads process type (`workerSet`/`staticPool`/`dynamicPool`)<br />- _startDelay_: milliseconds to wait at worker threads startup (only for `workerSet` worker threads process type)<br />- _elementStartDelay_: milliseconds to wait at charging station startup<br />- _elementsPerWorker_: number of charging stations per worker threads for the `workerSet` process type (`auto` means (number of stations) / (number of CPUs) \* 1.5 if (number of stations) > (number of CPUs), otherwise 1)<br />- _poolMinSize_: worker threads pool minimum number of threads</br >- _poolMaxSize_: worker threads pool maximum number of threads |
36782bfe 109| uiServer | | {<br />"enabled": false,<br />"type": "ws",<br />"version": "1.1",<br />"options": {<br />"host": "localhost",<br />"port": 8080<br />}<br />} | {<br />enabled: boolean;<br />type: ApplicationProtocol;<br />version: ApplicationProtocolVersion;<br />options: ServerOptions;<br />authentication: {<br />enabled: boolean;<br />type: AuthenticationType;<br />username: string;<br />password: string;<br />}<br />} | UI server configuration section:<br />- _enabled_: enable UI server<br />- _type_: 'http' or 'ws'<br />- _version_: HTTP version '1.1' or '2.0'<br />- _options_: node.js net module [listen options](https://nodejs.org/api/net.html#serverlistenoptions-callback) |
6e2f954c 110| performanceStorage | | {<br />"enabled": false,<br />"type": "jsonfile",<br />"uri": "file:///performance/performanceRecords.json"<br />} | {<br />enabled: boolean;<br />type: string;<br />uri: string;<br />} | Performance storage configuration section:<br />- _enabled_: enable performance storage<br />- _type_: 'jsonfile' or 'mongodb'<br />- _uri_: storage URI |
a6080904 111| stationTemplateUrls | | {}[] | {<br />file: string;<br />numberOfStations: number;<br />}[] | array of charging station configuration templates URIs configuration section (charging station configuration template file name and number of stations) |
e7aeea18 112
d6b76da3 113#### Worker process model
a6b3c6c3
JB
114
115- **workerSet**:
4c6ed1d7 116 Worker set executing each a static number (elementsPerWorker) of simulated charging stations from the total
a6b3c6c3
JB
117
118- **staticPool**:
e7aeea18 119 Statically sized worker pool executing a static total number of simulated charging stations
a6b3c6c3 120
56e2e1ab 121- **dynamicPool** (experimental):
e7aeea18 122 Dynamically sized worker pool executing a static total number of simulated charging stations
a6b3c6c3 123
1816f743
JB
124### Charging station configuration template
125
afccb423 126**src/assets/station-templates/\<name\>.json**:
1816f743 127
8603c1ca
JB
128| Key | Value(s) | Default Value | Value type | Description |
129| ---------------------------------------------------- | ------------- | ---------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
130| supervisionUrls | | [] | string \| string[] | string or strings array containing connection URIs to OCPP-J servers |
131| supervisionUser | | undefined | string | basic HTTP authentication user to OCPP-J server |
132| supervisionPassword | | undefined | string | basic HTTP authentication password to OCPP-J server |
133| supervisionUrlOcppConfiguration | true/false | false | boolean | allow supervision URL configuration via a vendor OCPP parameter key |
134| supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL |
135| ocppVersion | 1.6/2.0/2.0.1 | 1.6 | string | OCPP version |
136| ocppProtocol | json | json | string | OCPP protocol |
d0e58571 137| ocppStrictCompliance | true/false | true | boolean | strict adherence to the OCPP version and protocol specifications with OCPP commands PDU validation against [OCA](https://www.openchargealliance.org/) JSON schemas |
8603c1ca
JB
138| ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
139| stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
140| automaticTransactionGeneratorPersistentConfiguration | true/false | true | boolean | enable persistent automatic transaction generator configuration storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
141| wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection |
142| idTagsFile | | undefined | string | RFID tags list file relative to [src/assets](src/assets) path |
143| baseName | | undefined | string | base name to build charging stations id |
144| nameSuffix | | undefined | string | name suffix to build charging stations id |
145| fixedName | true/false | false | boolean | use the baseName as the charging stations unique name |
146| chargePointModel | | undefined | string | charging stations model |
147| chargePointVendor | | undefined | string | charging stations vendor |
148| chargePointSerialNumberPrefix | | undefined | string | charge point serial number prefix |
7cd86d34 149| chargeBoxSerialNumberPrefix | | undefined | string | charge box serial number prefix (deprecated since OCPP 1.6) |
8603c1ca
JB
150| firmwareVersionPattern | | Semantic versioning regular expression: https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string | string | charging stations firmware version pattern |
151| firmwareVersion | | undefined | string | charging stations firmware version |
152| power | | | float \| float[] | charging stations maximum power value(s) |
153| powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors |
154| powerUnit | W/kW | W | string | charging stations power unit |
155| currentOutType | AC/DC | AC | string | charging stations current out type |
156| voltageOut | | AC:230/DC:400 | integer | charging stations voltage out |
157| numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) |
158| numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) |
159| useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template |
160| randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template |
161| resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset |
162| autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose |
163| autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server |
164| reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server |
165| registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries |
166| amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC |
167| amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit |
168| enableStatistics | true/false | false | boolean | enable charging stations statistics |
cfdf901d 169| remoteAuthorization | true/false | true | boolean | enable RFID tags remote authorization |
8603c1ca
JB
170| beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues |
171| outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) |
172| meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis |
173| transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction |
174| mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations |
175| phaseLineToLineVoltageMeterValues | true/false | false | boolean | include charging stations line to line voltage MeterValues on three phased charging stations |
176| customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues |
177| firmwareUpgrade | | {<br />"versionUpgrade": {<br />"step": 1<br />},<br />"reset": true<br />} | {<br />versionUpgrade: {<br />patternGroup: number;<br />step: number;<br />};<br />reset: boolean;<br />failureStatus: 'DownloadFailed' \| 'InstallationFailed';<br />} | Configuration section for simulating firmware upgrade support. |
178| commandsSupport | | {<br />"incomingCommands": {},<br />"outgoingCommands": {}<br />} | {<br /> incomingCommands: Record<IncomingRequestCommand, boolean>;<br />outgoingCommands?: Record<RequestCommand, boolean>;<br />} | Configuration section for OCPP commands support. Empty section or subsections means all implemented OCPP commands are supported |
179| messageTriggerSupport | | {} | Record<MessageTrigger, boolean> | Configuration section for OCPP commands trigger support. Empty section means all implemented OCPP trigger commands are supported |
180| Configuration | | | ChargingStationOcppConfiguration | charging stations OCPP parameters configuration section |
181| AutomaticTransactionGenerator | | | AutomaticTransactionGeneratorConfiguration | charging stations ATG configuration section |
182| Connectors | | | Record<string, ConnectorStatus> | charging stations connectors configuration section |
183| Evses | | | Record<string, EvseTemplate> | charging stations EVSEs configuration section |
c94a349a 184
3e1dfe42 185#### Configuration section syntax example
c94a349a
JB
186
187```json
0302da79 188 "Configuration": {
c94a349a
JB
189 "configurationKey": [
190 ...
191 {
192 "key": "StandardKey",
193 "readonly": false,
194 "value": "StandardValue",
195 "visible": true,
196 "reboot": false
197 },
198 ...
199 {
200 "key": "VendorKey",
201 "readonly": false,
202 "value": "VendorValue",
203 "visible": false,
204 "reboot": true
205 },
206 ...
207 ]
208 }
209```
210
3e1dfe42 211#### AutomaticTransactionGenerator section syntax example
c94a349a 212
20f09970 213##### Type definition:
c72f6634
JB
214
215```ts
216type AutomaticTransactionGeneratorConfiguration = {
217 enable: boolean;
218 minDuration: number;
219 maxDuration: number;
220 minDelayBetweenTwoTransactions: number;
221 maxDelayBetweenTwoTransactions: number;
222 probabilityOfStart: number;
223 stopAfterHours: number;
224 stopOnConnectionFailure: boolean;
225 requireAuthorize?: boolean;
226 idTagDistribution?: 'random' | 'round-robin' | 'connector-affinity';
227};
228```
229
20f09970 230##### Example:
c72f6634 231
c94a349a 232```json
0302da79 233 "AutomaticTransactionGenerator": {
c94a349a
JB
234 "enable": false,
235 "minDuration": 60,
236 "maxDuration": 80,
237 "minDelayBetweenTwoTransactions": 15,
238 "maxDelayBetweenTwoTransactions": 30,
239 "probabilityOfStart": 1,
240 "stopAfterHours": 0.3,
241 "stopOnConnectionFailure": true,
c72f6634
JB
242 "requireAuthorize": true,
243 "idTagDistribution": "random"
c94a349a
JB
244 }
245```
e7aeea18 246
3e1dfe42 247#### Connectors section syntax example
c94a349a
JB
248
249```json
0302da79 250 "Connectors": {
c94a349a
JB
251 "0": {},
252 "1": {
253 "bootStatus": "Available",
254 "MeterValues": [
9bd87386
JB
255 ...
256 {
257 "unit": "W",
258 "measurand": "Power.Active.Import",
259 "phase": "L1-N",
260 "value": "5000",
261 "fluctuationPercent": "10"
262 },
c94a349a
JB
263 ...
264 {
265 "unit": "A",
860ef183
JB
266 "measurand": "Current.Import",
267 "minimum": "0.5"
c94a349a
JB
268 },
269 ...
270 {
271 "unit": "Wh"
272 },
273 ...
274 ]
275 }
276 },
277```
278
3e1dfe42
JB
279#### Evses section syntax example
280
281```json
282 "Evses": {
283 "0": {
284 "Connectors": {
285 "0": {}
286 }
287 },
288 "1": {
289 "Connectors": {
290 "1": {
291 "bootStatus": "Available",
292 "MeterValues": [
293 ...
294 {
295 "unit": "W",
296 "measurand": "Power.Active.Import",
297 "phase": "L1-N",
298 "value": "5000",
299 "fluctuationPercent": "10"
300 },
301 ...
302 {
303 "unit": "A",
304 "measurand": "Current.Import",
305 "minimum": "0.5"
306 },
307 ...
308 {
309 "unit": "Wh"
310 },
311 ...
312 ]
313 }
314 }
315 }
316 },
317```
318
1816f743
JB
319### Charging station configuration
320
1c51fd1d 321**dist/assets/configurations/\<hashId\>.json**:
1816f743 322
a9ec2018 323The charging station configuration file is automatically generated at startup from the charging station configuration template file and is persistent.
1816f743
JB
324
325The charging station configuration file content can be regenerated partially on matching charging station configuration template file changes. The charging station serial number is kept unchanged.
326
327#### stationInfo section
328
329The syntax is similar to charging station configuration template with some added fields like the charging station id (name) and the 'Configuration' section removed.
330
331#### configurationKey section
332
333The syntax is similar to the charging station configuration template 'Configuration' section.
334
3a28512c
JB
335#### automaticTransactionGenerator section
336
337The syntax is similar to the charging station configuration template 'AutomaticTransactionGenerator' section.
338
6f0ec20e
JB
339## Docker
340
341In the [docker](./docker) folder:
342
343```bash
344make
345```
346
673dceeb 347<!-- Or with the optional git submodules:
6f0ec20e
JB
348
349```bash
bfcad885 350make SUBMODULES_INIT=true
673dceeb 351``` -->
6f0ec20e
JB
352
353## OCPP-J commands supported
c94a349a
JB
354
355### Version 1.6
356
c56d42f1 357#### Core Profile
6f0ec20e 358
778f7924
JB
359- :white_check_mark: Authorize
360- :white_check_mark: BootNotification
361- :white_check_mark: ChangeAvailability
362- :white_check_mark: ChangeConfiguration
363- :white_check_mark: ClearCache
91a7d3ea 364- :white_check_mark: DataTransfer
778f7924
JB
365- :white_check_mark: GetConfiguration
366- :white_check_mark: Heartbeat
367- :white_check_mark: MeterValues
368- :white_check_mark: RemoteStartTransaction
369- :white_check_mark: RemoteStopTransaction
370- :white_check_mark: Reset
371- :white_check_mark: StartTransaction
372- :white_check_mark: StatusNotification
373- :white_check_mark: StopTransaction
374- :white_check_mark: UnlockConnector
6f0ec20e 375
c56d42f1 376#### Firmware Management Profile
6f0ec20e 377
b652b0c3 378- :white_check_mark: GetDiagnostics
d50343bd 379- :white_check_mark: DiagnosticsStatusNotification
c9a4f9ea
JB
380- :white_check_mark: FirmwareStatusNotification
381- :white_check_mark: UpdateFirmware
6f0ec20e 382
c56d42f1 383#### Local Auth List Management Profile
6f0ec20e 384
9e1b12e4
JB
385- :x: GetLocalListVersion
386- :x: SendLocalList
6f0ec20e 387
c56d42f1 388#### Reservation Profile
6f0ec20e 389
24578c31
JB
390- :white_check_mark: CancelReservation
391- :white_check_mark: ReserveNow
6f0ec20e 392
c56d42f1 393#### Smart Charging Profile
6f0ec20e 394
778f7924 395- :white_check_mark: ClearChargingProfile
e1d9a0f4 396- :white_check_mark: GetCompositeSchedule
778f7924 397- :white_check_mark: SetChargingProfile
6f0ec20e 398
c56d42f1 399#### Remote Trigger Profile
6f0ec20e 400
802cfa13 401- :white_check_mark: TriggerMessage
7dde0b73 402
d4371252
JB
403### Version 2.x.x
404
405#### Provisioning
406
407- :white_check_mark: BootNotification
408
bc950df1 409#### Authorization
d4371252
JB
410
411- :white_check_mark: ClearCache
412
413#### Availability
414
415- :white_check_mark: StatusNotification
416- :white_check_mark: Heartbeat
417
7e1dc878
JB
418## OCPP-J standard parameters supported
419
3a28512c 420All kind of OCPP parameters are supported in charging station configuration or charging station configuration template file. The list here mention the standard ones also handled automatically in the simulator.
7e1dc878
JB
421
422### Version 1.6
423
c56d42f1 424#### Core Profile
7e1dc878
JB
425
426- :white_check_mark: AuthorizeRemoteTxRequests (type: boolean) (units: -)
427- :x: ClockAlignedDataInterval (type: integer) (units: seconds)
291cb255 428- :white_check_mark: ConnectionTimeOut (type: integer) (units: seconds)
7e1dc878
JB
429- :x: GetConfigurationMaxKeys (type: integer) (units: -)
430- :white_check_mark: HeartbeatInterval (type: integer) (units: seconds)
431- :x: LocalAuthorizeOffline (type: boolean) (units: -)
432- :x: LocalPreAuthorize (type: boolean) (units: -)
433- :x: MeterValuesAlignedData (type: CSL) (units: -)
434- :white_check_mark: MeterValuesSampledData (type: CSL) (units: -)
435- :white_check_mark: MeterValueSampleInterval (type: integer) (units: seconds)
436- :white_check_mark: NumberOfConnectors (type: integer) (units: -)
437- :x: ResetRetries (type: integer) (units: times)
438- :white_check_mark: ConnectorPhaseRotation (type: CSL) (units: -)
439- :x: StopTransactionOnEVSideDisconnect (type: boolean) (units: -)
440- :x: StopTransactionOnInvalidId (type: boolean) (units: -)
441- :x: StopTxnAlignedData (type: CSL) (units: -)
442- :x: StopTxnSampledData (type: CSL) (units: -)
36f6a92e 443- :white_check_mark: SupportedFeatureProfiles (type: CSL) (units: -)
7e1dc878
JB
444- :x: TransactionMessageAttempts (type: integer) (units: times)
445- :x: TransactionMessageRetryInterval (type: integer) (units: seconds)
446- :x: UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -)
36f6a92e 447- :white_check_mark: WebSocketPingInterval (type: integer) (units: seconds)
7e1dc878 448
c56d42f1 449#### Firmware Management Profile
7e1dc878 450
e7aeea18 451- _none_
7e1dc878 452
c56d42f1 453#### Local Auth List Management Profile
7e1dc878 454
36f6a92e 455- :white_check_mark: LocalAuthListEnabled (type: boolean) (units: -)
7e1dc878
JB
456- :x: LocalAuthListMaxLength (type: integer) (units: -)
457- :x: SendLocalListMaxLength (type: integer) (units: -)
458
c56d42f1 459#### Reservation Profile
7e1dc878 460
66dd3447 461- :white_check_mark: ReserveConnectorZeroSupported (type: boolean) (units: -)
7e1dc878 462
c56d42f1 463#### Smart Charging Profile
7e1dc878
JB
464
465- :x: ChargeProfileMaxStackLevel (type: integer) (units: -)
466- :x: ChargingScheduleAllowedChargingRateUnit (type: CSL) (units: -)
467- :x: ChargingScheduleMaxPeriods (type: integer) (units: -)
468- :x: MaxChargingProfilesInstalled (type: integer) (units: -)
469
c56d42f1 470#### Remote Trigger Profile
7e1dc878 471
e7aeea18 472- _none_
7e1dc878 473
d4371252
JB
474### Version 2.x.x
475
32de5a57
LM
476## UI protocol
477
03ebf4c1 478Protocol to control the simulator via a Websocket or HTTP server.
32de5a57 479
4df14d3a
JB
480### HTTP Protocol
481
97c19696 482To learn how to use the HTTP protocol to pilot the simulator, an [Insomnia](https://insomnia.rest/) HTTP requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory.
4df14d3a 483
02cde3b7 484### Websocket Protocol
32de5a57 485
02cde3b7 486SRPC protocol over Websocket. PDU stands for 'Protocol Data Unit'.
32de5a57 487
03ebf4c1
JB
488- Request:
489 [`uuid`, `ProcedureName`, `PDU`]
490 `uuid`: String uniquely representing this request
491 `ProcedureName`: The procedure to run on the simulator
492 `PDU`: The parameters for said procedure
32de5a57 493
03ebf4c1
JB
494- Response:
495 [`uuid`, `PDU`]
496 `uuid`: String uniquely linking the response to the request
02cde3b7 497 `PDU`: Response parameters to requested procedure
32de5a57 498
97c19696
JB
499An [Insomnia](https://insomnia.rest/) WebSocket requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory.
500
d3140adc 501#### Version 0.0.1
4e3ff94d 502
02cde3b7 503Set the Websocket header _Sec-Websocket-Protocol_ to `ui0.0.1`.
4e3ff94d 504
d3140adc 505##### Procedures
32de5a57 506
d3140adc 507###### Start Simulator
5612b691 508
03ebf4c1
JB
509- Request:
510 `ProcedureName`: 'startSimulator'
511 `PDU`: {}
5612b691 512
03ebf4c1
JB
513- Response:
514 `PDU`: {
853ed24a 515 `status`: 'success' | 'failure'
03ebf4c1 516 }
5612b691 517
d3140adc 518###### Stop Simulator
5612b691 519
03ebf4c1
JB
520- Request:
521 `ProcedureName`: 'stopSimulator'
522 `PDU`: {}
5612b691 523
03ebf4c1
JB
524- Response:
525 `PDU`: {
853ed24a 526 `status`: 'success' | 'failure'
03ebf4c1 527 }
5612b691 528
d3140adc 529###### List Charging Stations
32de5a57 530
03ebf4c1
JB
531- Request:
532 `ProcedureName`: 'listChargingStations'
533 `PDU`: {}
32de5a57 534
03ebf4c1
JB
535- Response:
536 `PDU`: {
853ed24a 537 `status`: 'success' | 'failure',
02cde3b7 538 `chargingStations`: ChargingStationData[]
03ebf4c1 539 }
32de5a57 540
d3140adc 541###### Start Charging Station
80a3704c 542
03ebf4c1
JB
543- Request:
544 `ProcedureName`: 'startChargingStation'
545 `PDU`: {
03eee93b 546 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
03ebf4c1 547 }
80a3704c 548
03ebf4c1
JB
549- Response:
550 `PDU`: {
853ed24a
JB
551 `status`: 'success' | 'failure',
552 `hashIdsSucceeded`: charging station unique identifier strings array,
553 `hashIdsFailed`: charging station unique identifier strings array (optional)
03eee93b 554 `responsesFailed`: failed responses payload array (optional)
03ebf4c1 555 }
80a3704c 556
d3140adc 557###### Stop Charging Station
80a3704c 558
03ebf4c1
JB
559- Request:
560 `ProcedureName`: 'stopChargingStation'
561 `PDU`: {
853ed24a 562 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
03ebf4c1 563 }
80a3704c 564
03ebf4c1
JB
565- Response:
566 `PDU`: {
853ed24a
JB
567 `status`: 'success' | 'failure',
568 `hashIdsSucceeded`: charging station unique identifier strings array,
94abe068
JB
569 `hashIdsFailed`: charging station unique identifier strings array (optional),
570 `responsesFailed`: failed responses payload array (optional)
03ebf4c1 571 }
80a3704c 572
d3140adc 573###### Open Connection
e4df816e 574
03ebf4c1
JB
575- Request:
576 `ProcedureName`: 'openConnection'
577 `PDU`: {
853ed24a 578 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
03ebf4c1 579 }
e4df816e 580
03ebf4c1
JB
581- Response:
582 `PDU`: {
853ed24a
JB
583 `status`: 'success' | 'failure',
584 `hashIdsSucceeded`: charging station unique identifier strings array,
94abe068
JB
585 `hashIdsFailed`: charging station unique identifier strings array (optional),
586 `responsesFailed`: failed responses payload array (optional)
03ebf4c1 587 }
e4df816e 588
d3140adc 589###### Close Connection
e4df816e 590
03ebf4c1
JB
591- Request:
592 `ProcedureName`: 'closeConnection'
593 `PDU`: {
853ed24a 594 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
03ebf4c1
JB
595 }
596
597- Response:
598 `PDU`: {
853ed24a
JB
599 `status`: 'success' | 'failure',
600 `hashIdsSucceeded`: charging station unique identifier strings array,
94abe068
JB
601 `hashIdsFailed`: charging station unique identifier strings array (optional),
602 `responsesFailed`: failed responses payload array (optional)
853ed24a
JB
603 }
604
605###### Start Automatic Transaction Generator
606
607- Request:
608 `ProcedureName`: 'startAutomaticTransactionGenerator'
609 `PDU`: {
610 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
a38bc315 611 `connectorIds`: connector id integer array (optional, default: all connectors)
853ed24a
JB
612 }
613
614- Response:
615 `PDU`: {
616 `status`: 'success' | 'failure',
617 `hashIdsSucceeded`: charging station unique identifier strings array,
5566ca3e
JB
618 `hashIdsFailed`: charging station unique identifier strings array (optional),
619 `responsesFailed`: failed responses payload array (optional)
853ed24a
JB
620 }
621
622###### Stop Automatic Transaction Generator
623
624- Request:
625 `ProcedureName`: 'stopAutomaticTransactionGenerator'
626 `PDU`: {
627 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
a38bc315 628 `connectorIds`: connector id integer array (optional, default: all connectors)
853ed24a
JB
629 }
630
631- Response:
632 `PDU`: {
633 `status`: 'success' | 'failure',
634 `hashIdsSucceeded`: charging station unique identifier strings array,
5566ca3e
JB
635 `hashIdsFailed`: charging station unique identifier strings array (optional),
636 `responsesFailed`: failed responses payload array (optional)
03ebf4c1
JB
637 }
638
91a7d3ea 639###### OCPP commands trigger
a9ed42b2 640
82cbef8d
JB
641- Request:
642 `ProcedureName`: 'commandName' (the OCPP command name in camel case)
643 `PDU`: {
644 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
645 ...`commandPayload`
646 } (the OCPP command payload with some optional fields added to target the simulated charging stations)
10db00b2 647
82cbef8d
JB
648- Response:
649 `PDU`: {
650 `status`: 'success' | 'failure',
651 `hashIdsSucceeded`: charging station unique identifier strings array,
652 `hashIdsFailed`: charging station unique identifier strings array (optional),
653 `responsesFailed`: failed responses payload array (optional)
654 }
10db00b2 655
91a7d3ea 656Examples:
10db00b2 657
91a7d3ea 658- **Start Transaction**
a9ed42b2 659
91a7d3ea
JB
660 - Request:
661 `ProcedureName`: 'startTransaction'
662 `PDU`: {
663 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
664 `connectorId`: connector id integer,
665 `idTag`: RFID tag string
666 }
667
668 - Response:
669 `PDU`: {
670 `status`: 'success' | 'failure',
671 `hashIdsSucceeded`: charging station unique identifier strings array,
672 `hashIdsFailed`: charging station unique identifier strings array (optional),
673 `responsesFailed`: failed responses payload array (optional)
674 }
675
676- **Stop Transaction**
677
678 - Request:
679 `ProcedureName`: 'stopTransaction'
680 `PDU`: {
681 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
682 `transactionId`: transaction id integer
683 }
684
685 - Response:
686 `PDU`: {
687 `status`: 'success' | 'failure',
688 `hashIdsSucceeded`: charging station unique identifier strings array,
689 `hashIdsFailed`: charging station unique identifier strings array (optional),
690 `responsesFailed`: failed responses payload array (optional)
691 }
692
693- **Status Notification**
694
695 - Request:
82cbef8d 696 `ProcedureName`: 'statusNotification'
91a7d3ea
JB
697 `PDU`: {
698 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
699 `connectorId`: connector id integer,
700 `errorCode`: connector error code,
701 `status`: connector status
702 }
703
704 - Response:
705 `PDU`: {
706 `status`: 'success' | 'failure',
707 `hashIdsSucceeded`: charging station unique identifier strings array,
708 `hashIdsFailed`: charging station unique identifier strings array (optional),
709 `responsesFailed`: failed responses payload array (optional)
710 }
711
712- **Heartbeat**
713
714 - Request:
82cbef8d 715 `ProcedureName`: 'heartbeat'
91a7d3ea
JB
716 `PDU`: {
717 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
718 }
719
720 - Response:
721 `PDU`: {
722 `status`: 'success' | 'failure',
723 `hashIdsSucceeded`: charging station unique identifier strings array,
724 `hashIdsFailed`: charging station unique identifier strings array (optional),
725 `responsesFailed`: failed responses payload array (optional)
726 }
a9ed42b2 727
251fff5c 728## Support, Feedback, Contributing
7dde0b73 729
7f774a55 730This project is open to feature requests/suggestions, bug reports etc. via [GitHub issues](https://github.com/SAP/e-mobility-charging-stations-simulator/issues). Contribution and feedback are encouraged and always welcome. For more information about how to contribute, the project structure, as well as additional contribution information, see our [Contribution Guidelines](CONTRIBUTING.md).
7dde0b73 731
251fff5c
JB
732## Code of Conduct
733
734We as members, contributors, and leaders pledge to make participation in our community a harassment-free experience for everyone. By participating in this project, you agree to abide by its [Code of Conduct](CODE_OF_CONDUCT.md) at all times.
735
736## Licensing
737
a6609c86 738Copyright 2020-2023 SAP SE or an SAP affiliate company and e-mobility-charging-stations-simulator contributors. Please see our [LICENSE](LICENSE) for copyright and license information. Detailed information including third-party components and their licensing/copyright information is available [via the REUSE tool](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator).