docs: improve configuration file documentation
[e-mobility-charging-stations-simulator.git] / README.md
CommitLineData
d6b76da3 1<!-- markdownlint-disable-file MD033 MD024 -->
9e0845f7 2
1ea2264a 3# [e-mobility charging stations simulator](https://github.com/sap/e-mobility-charging-stations-simulator)
7dde0b73 4
b0b6537f
JB
5[![GitHub Clones](https://img.shields.io/badge/dynamic/json?color=brightgreen&label=Clone&query=count&url=https://gist.githubusercontent.com/jerome-benoit/c7c669b881d5b27dc0b44a639504ff93/raw/clone.json&logo=github)](https://github.com/SAP/e-mobility-charging-stations-simulator/graphs/traffic)
6[![GitHub commit activity (main)](https://img.shields.io/github/commit-activity/m/SAP/e-mobility-charging-stations-simulator/main?color=brightgreen&logo=github)](https://github.com/SAP/e-mobility-charging-stations-simulator/graphs/commit-activity)
f1fded7b 7[![CI workflow](https://github.com/SAP/e-mobility-charging-stations-simulator/actions/workflows/ci.yml/badge.svg)](https://github.com/SAP/e-mobility-charging-stations-simulator/actions/workflows/ci.yml)
4d188eb9 8[![REUSE status](https://api.reuse.software/badge/github.com/SAP/e-mobility-charging-stations-simulator)](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator)
b157a1df 9[![Javascript Standard Style Guide](<https://badgen.net/static/code style/standard/green>)](https://standardjs.com)
0a3d08ef 10
7dde0b73
JB
11## Summary
12
a712de6f 13Simple [node.js](https://nodejs.org/) software to simulate and scale a set of charging stations based on the OCPP-J protocol as part of [SAP e-Mobility](https://www.sap.com/products/scm/e-mobility.html) solution.
7dde0b73 14
696ce53a
JB
15## Prerequisites
16
5845e83d 17Install the [node.js](https://nodejs.org/) current LTS or superior version runtime environment:
007ee642 18
696ce53a
JB
19### Windows
20
e7aeea18 21- [Chocolatey](https://chocolatey.org/):
696ce53a
JB
22
23```powershell
5845e83d 24choco install -y nodejs
696ce53a
JB
25```
26
27### MacOSX
28
e7aeea18 29- [Homebrew](https://brew.sh/):
696ce53a
JB
30
31```shell
5845e83d 32brew install node
696ce53a
JB
33```
34
d6b76da3 35### GNU/Linux
511780c3 36
eef659c1 37- [NodeSource](https://github.com/nodesource/distributions) Node.js Binary Distributions for all supported versions.
511780c3 38
007ee642
JB
39## Installation
40
1a662d29 41Enable corepack if not already done and install latest pnpm version:
5845e83d
JB
42
43```shell
44corepack enable
1a662d29 45corepack prepare pnpm@latest --activate
5845e83d
JB
46```
47
007ee642
JB
48In the repository root, run the following command:
49
50```shell
881f450c 51pnpm install
007ee642
JB
52```
53
54## Initial configuration
55
db70b600 56Copy the configuration template file [src/assets/config-template.json](src/assets/config-template.json) to [src/assets/config.json](src/assets/config.json).
e302df1d 57Copy the RFID tags template file [src/assets/idtags-template.json](src/assets/idtags-template.json) to [src/assets/idtags.json](src/assets/idtags.json).
db70b600 58
58b0ee76 59Tweak them to your needs by following the section [configuration files syntax](README.md#configuration-files-syntax): OCPP server supervision URL(s), charging station templates, etc.
007ee642
JB
60
61## Start
62
881f450c 63To start the program, run: `pnpm start`.
007ee642 64
4e3ff94d 65## Start Web UI
007ee642 66
ebbfbf1c 67See Web UI [README.md](ui/web/README.md) for more information.
b8cc885d 68
4d3821a2 69## Configuration files syntax
2c28fc83 70
e7aeea18 71All configuration files are in the JSON standard format.
2c28fc83 72
ff82dc5f 73**Configuration files locations**:
2c28fc83 74
170bec53 75- charging stations simulator configuration: [src/assets/config.json](src/assets/config.json);
1816f743 76- charging station configuration templates: [src/assets/station-templates](src/assets/station-templates);
1c51fd1d 77- charging station configurations: [dist/assets/configurations](dist/assets/configurations);
7f818162 78- charging station RFID tags lists: [src/assets](src/assets).
2c28fc83 79
1816f743
JB
80The charging stations simulator's configuration parameters must be within the `src/assets/config.json` file. A charging station simulator configuration template file is available at [src/assets/config-template.json](src/assets/config-template.json).
81
82All charging station configuration templates are in the directory [src/assets/station-templates](src/assets/station-templates).
83
3a28512c 84A list of RFID tags must be defined for the automatic transaction generator in a file with the default location and name: `src/assets/idtags.json`. A template file is available at [src/assets/idtags-template.json](src/assets/idtags-template.json).
1816f743
JB
85
86**Configuration files hierarchy and priority**:
87
1c51fd1d 881. charging station configuration: [dist/assets/configurations](dist/assets/configurations);
1816f743 892. charging station configuration template: [src/assets/station-templates](src/assets/station-templates);
170bec53 903. charging stations simulator configuration: [src/assets/config.json](src/assets/config.json).
511780c3 91
3a28512c 92The charging stations simulator has an automatic configuration files reload feature at change for:
511780c3 93
170bec53 94- charging stations simulator configuration;
1816f743 95- charging station configuration templates;
170bec53 96- charging station authorization RFID tags lists.
2c28fc83 97
3a28512c 98But the modifications to test have to be done to the files in the build target directory [dist/assets](dist/assets). Once the modifications are done, they have to be reported to the matching files in the build source directory [src/assets](src/assets) to ensure they will be taken into account at next build.
e7aeea18 99
170bec53 100### Charging stations simulator configuration
2c28fc83 101
b1d6e944 102**src/assets/config.json**:
2c28fc83 103
c20d5d72
JB
104| Key | Value(s) | Default Value | Value type | Description |
105| -------------------------- | -------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
106| supervisionUrls | | [] | string \| string[] | string or strings array containing global connection URIs to OCPP-J servers |
107| supervisionUrlDistribution | round-robin/random/charging-station-affinity | charging-station-affinity | string | supervision urls distribution policy to simulated charging stations |
108| log | | {<br />"enabled": true,<br />"file": "logs/combined.log",<br />"errorFile": "logs/error.log",<br />"statisticsInterval": 60,<br />"level": "info",<br />"console": false,<br />"format": "simple",<br />"rotate": true<br />} | {<br />enabled: boolean;<br />file: string;<br />errorFile: string;<br />statisticsInterval: number;<br />level: string;<br />console: boolean;<br />format: string;<br />rotate: boolean;<br />maxFiles: string \| number;<br />maxSize: string \| number;<br />} | Log configuration section:<br />- _enabled_: enable logging<br />- _file_: log file relative path<br />- _errorFile_: error log file relative path<br />- _statisticsInterval_: seconds between charging stations statistics output in the logs<br />- _level_: emerg/alert/crit/error/warning/notice/info/debug [winston](https://github.com/winstonjs/winston) logging level</br >- _console_: output logs on the console<br />- _format_: [winston](https://github.com/winstonjs/winston) log format<br />- _rotate_: enable daily log files rotation<br />- _maxFiles_: maximum number of log files: https://github.com/winstonjs/winston-daily-rotate-file#options<br />- _maxSize_: maximum size of log files in bytes, or units of kb, mb, and gb: https://github.com/winstonjs/winston-daily-rotate-file#options |
109| worker | | {<br />"processType": "workerSet",<br />"startDelay": 500,<br />"elementStartDelay": 0,<br />"elementsPerWorker": 'auto',<br />"poolMinSize": 4,<br />"poolMaxSize": 16<br />} | {<br />processType: WorkerProcessType;<br />startDelay: number;<br />elementStartDelay: number;<br />elementsPerWorker: number \| 'auto' \| 'all';<br />poolMinSize: number;<br />poolMaxSize: number;<br />} | Worker configuration section:<br />- _processType_: worker threads process type (`workerSet`/`fixedPool`/`dynamicPool`)<br />- _startDelay_: milliseconds to wait at worker threads startup (only for `workerSet` worker threads process type)<br />- _elementStartDelay_: milliseconds to wait at charging station startup<br />- _elementsPerWorker_: number of charging stations per worker threads for the `workerSet` process type (`auto` means (number of stations) / (number of CPUs) \* 1.5 if (number of stations) > (number of CPUs), otherwise 1; `all` means a unique worker will run all charging stations)<br />- _poolMinSize_: worker threads pool minimum number of threads</br >- _poolMaxSize_: worker threads pool maximum number of threads<br />- _resourceLimits_: worker threads [resource limits](https://nodejs.org/api/worker_threads.html#new-workerfilename-options) object option |
110| uiServer | | {<br />"enabled": false,<br />"type": "ws",<br />"version": "1.1",<br />"options": {<br />"host": "localhost",<br />"port": 8080<br />}<br />} | {<br />enabled: boolean;<br />type: ApplicationProtocol;<br />version: ApplicationProtocolVersion;<br />options: ServerOptions;<br />authentication: {<br />enabled: boolean;<br />type: AuthenticationType;<br />username: string;<br />password: string;<br />}<br />} | UI server configuration section:<br />- _enabled_: enable UI server<br />- _type_: 'http' or 'ws'<br />- _version_: HTTP version '1.1' or '2.0'<br />- _options_: node.js net module [listen options](https://nodejs.org/api/net.html#serverlistenoptions-callback) |
111| performanceStorage | | {<br />"enabled": false,<br />"type": "jsonfile",<br />"uri": "file:///performance/performanceRecords.json"<br />} | {<br />enabled: boolean;<br />type: string;<br />uri: string;<br />} | Performance storage configuration section:<br />- _enabled_: enable performance storage<br />- _type_: 'jsonfile' or 'mongodb'<br />- _uri_: storage URI |
112| stationTemplateUrls | | {}[] | {<br />file: string;<br />numberOfStations: number;<br />}[] | array of charging station configuration templates URIs configuration section (charging station configuration template file name and number of stations) |
e7aeea18 113
d6b76da3 114#### Worker process model
a6b3c6c3
JB
115
116- **workerSet**:
1d8f226b 117 Worker set executing each a fixed number (elementsPerWorker) of simulated charging stations from the total
a6b3c6c3 118
1d8f226b
JB
119- **fixedPool**:
120 Fixedly sized worker pool executing a fixed total number of simulated charging stations
a6b3c6c3 121
56e2e1ab 122- **dynamicPool** (experimental):
1d8f226b 123 Dynamically sized worker pool executing a fixed total number of simulated charging stations
a6b3c6c3 124
1816f743
JB
125### Charging station configuration template
126
afccb423 127**src/assets/station-templates/\<name\>.json**:
1816f743 128
8603c1ca
JB
129| Key | Value(s) | Default Value | Value type | Description |
130| ---------------------------------------------------- | ------------- | ---------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------ | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
131| supervisionUrls | | [] | string \| string[] | string or strings array containing connection URIs to OCPP-J servers |
132| supervisionUser | | undefined | string | basic HTTP authentication user to OCPP-J server |
133| supervisionPassword | | undefined | string | basic HTTP authentication password to OCPP-J server |
134| supervisionUrlOcppConfiguration | true/false | false | boolean | allow supervision URL configuration via a vendor OCPP parameter key |
135| supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL |
136| ocppVersion | 1.6/2.0/2.0.1 | 1.6 | string | OCPP version |
137| ocppProtocol | json | json | string | OCPP protocol |
d0e58571 138| ocppStrictCompliance | true/false | true | boolean | strict adherence to the OCPP version and protocol specifications with OCPP commands PDU validation against [OCA](https://www.openchargealliance.org/) JSON schemas |
8603c1ca
JB
139| ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
140| stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
141| automaticTransactionGeneratorPersistentConfiguration | true/false | true | boolean | enable persistent automatic transaction generator configuration storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
142| wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection |
143| idTagsFile | | undefined | string | RFID tags list file relative to [src/assets](src/assets) path |
144| baseName | | undefined | string | base name to build charging stations id |
145| nameSuffix | | undefined | string | name suffix to build charging stations id |
146| fixedName | true/false | false | boolean | use the baseName as the charging stations unique name |
147| chargePointModel | | undefined | string | charging stations model |
148| chargePointVendor | | undefined | string | charging stations vendor |
149| chargePointSerialNumberPrefix | | undefined | string | charge point serial number prefix |
7cd86d34 150| chargeBoxSerialNumberPrefix | | undefined | string | charge box serial number prefix (deprecated since OCPP 1.6) |
8603c1ca
JB
151| firmwareVersionPattern | | Semantic versioning regular expression: https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string | string | charging stations firmware version pattern |
152| firmwareVersion | | undefined | string | charging stations firmware version |
153| power | | | float \| float[] | charging stations maximum power value(s) |
154| powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors |
155| powerUnit | W/kW | W | string | charging stations power unit |
156| currentOutType | AC/DC | AC | string | charging stations current out type |
157| voltageOut | | AC:230/DC:400 | integer | charging stations voltage out |
158| numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) |
159| numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) |
160| useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template |
161| randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template |
162| resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset |
163| autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose |
164| autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server |
165| reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server |
166| registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries |
167| amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC |
168| amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit |
169| enableStatistics | true/false | false | boolean | enable charging stations statistics |
cfdf901d 170| remoteAuthorization | true/false | true | boolean | enable RFID tags remote authorization |
8603c1ca
JB
171| beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues |
172| outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) |
173| meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis |
174| transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction |
ab11404a 175| stopTransactionsOnStopped | true/false | true | boolean | enable stop transactions on charging station stop |
8603c1ca
JB
176| mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations |
177| phaseLineToLineVoltageMeterValues | true/false | false | boolean | include charging stations line to line voltage MeterValues on three phased charging stations |
178| customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues |
179| firmwareUpgrade | | {<br />"versionUpgrade": {<br />"step": 1<br />},<br />"reset": true<br />} | {<br />versionUpgrade: {<br />patternGroup: number;<br />step: number;<br />};<br />reset: boolean;<br />failureStatus: 'DownloadFailed' \| 'InstallationFailed';<br />} | Configuration section for simulating firmware upgrade support. |
180| commandsSupport | | {<br />"incomingCommands": {},<br />"outgoingCommands": {}<br />} | {<br /> incomingCommands: Record<IncomingRequestCommand, boolean>;<br />outgoingCommands?: Record<RequestCommand, boolean>;<br />} | Configuration section for OCPP commands support. Empty section or subsections means all implemented OCPP commands are supported |
181| messageTriggerSupport | | {} | Record<MessageTrigger, boolean> | Configuration section for OCPP commands trigger support. Empty section means all implemented OCPP trigger commands are supported |
182| Configuration | | | ChargingStationOcppConfiguration | charging stations OCPP parameters configuration section |
183| AutomaticTransactionGenerator | | | AutomaticTransactionGeneratorConfiguration | charging stations ATG configuration section |
184| Connectors | | | Record<string, ConnectorStatus> | charging stations connectors configuration section |
185| Evses | | | Record<string, EvseTemplate> | charging stations EVSEs configuration section |
c94a349a 186
3e1dfe42 187#### Configuration section syntax example
c94a349a
JB
188
189```json
0302da79 190 "Configuration": {
c94a349a
JB
191 "configurationKey": [
192 ...
193 {
194 "key": "StandardKey",
195 "readonly": false,
196 "value": "StandardValue",
197 "visible": true,
198 "reboot": false
199 },
200 ...
201 {
202 "key": "VendorKey",
203 "readonly": false,
204 "value": "VendorValue",
205 "visible": false,
206 "reboot": true
207 },
208 ...
209 ]
210 }
211```
212
3e1dfe42 213#### AutomaticTransactionGenerator section syntax example
c94a349a 214
20f09970 215##### Type definition:
c72f6634
JB
216
217```ts
218type AutomaticTransactionGeneratorConfiguration = {
66a7748d
JB
219 enable: boolean
220 minDuration: number
221 maxDuration: number
222 minDelayBetweenTwoTransactions: number
223 maxDelayBetweenTwoTransactions: number
224 probabilityOfStart: number
225 stopAfterHours: number
46a830d2 226 stopAbsoluteDuration: boolean
66a7748d
JB
227 stopOnConnectionFailure: boolean
228 requireAuthorize?: boolean
229 idTagDistribution?: 'random' | 'round-robin' | 'connector-affinity'
230}
c72f6634
JB
231```
232
20f09970 233##### Example:
c72f6634 234
c94a349a 235```json
0302da79 236 "AutomaticTransactionGenerator": {
c94a349a
JB
237 "enable": false,
238 "minDuration": 60,
239 "maxDuration": 80,
240 "minDelayBetweenTwoTransactions": 15,
241 "maxDelayBetweenTwoTransactions": 30,
242 "probabilityOfStart": 1,
243 "stopAfterHours": 0.3,
244 "stopOnConnectionFailure": true,
c72f6634
JB
245 "requireAuthorize": true,
246 "idTagDistribution": "random"
c94a349a
JB
247 }
248```
e7aeea18 249
3e1dfe42 250#### Connectors section syntax example
c94a349a
JB
251
252```json
0302da79 253 "Connectors": {
c94a349a
JB
254 "0": {},
255 "1": {
256 "bootStatus": "Available",
257 "MeterValues": [
9bd87386
JB
258 ...
259 {
260 "unit": "W",
261 "measurand": "Power.Active.Import",
262 "phase": "L1-N",
263 "value": "5000",
264 "fluctuationPercent": "10"
265 },
c94a349a
JB
266 ...
267 {
268 "unit": "A",
860ef183
JB
269 "measurand": "Current.Import",
270 "minimum": "0.5"
c94a349a
JB
271 },
272 ...
273 {
274 "unit": "Wh"
275 },
276 ...
277 ]
278 }
279 },
280```
281
3e1dfe42
JB
282#### Evses section syntax example
283
284```json
285 "Evses": {
286 "0": {
287 "Connectors": {
288 "0": {}
289 }
290 },
291 "1": {
292 "Connectors": {
293 "1": {
294 "bootStatus": "Available",
295 "MeterValues": [
296 ...
297 {
298 "unit": "W",
299 "measurand": "Power.Active.Import",
300 "phase": "L1-N",
301 "value": "5000",
302 "fluctuationPercent": "10"
303 },
304 ...
305 {
306 "unit": "A",
307 "measurand": "Current.Import",
308 "minimum": "0.5"
309 },
310 ...
311 {
312 "unit": "Wh"
313 },
314 ...
315 ]
316 }
317 }
318 }
319 },
320```
321
1816f743
JB
322### Charging station configuration
323
1c51fd1d 324**dist/assets/configurations/\<hashId\>.json**:
1816f743 325
a9ec2018 326The charging station configuration file is automatically generated at startup from the charging station configuration template file and is persistent.
1816f743
JB
327
328The charging station configuration file content can be regenerated partially on matching charging station configuration template file changes. The charging station serial number is kept unchanged.
329
330#### stationInfo section
331
332The syntax is similar to charging station configuration template with some added fields like the charging station id (name) and the 'Configuration' section removed.
333
10211789 334That section is overwritten on matching charging station configuration template file changes.
1816f743 335
10211789
JB
336#### connectorsStatus section
337
338The syntax is similar to charging station configuration template 'Connectors' section with some added fields.
339
340That section is overwritten on matching charging station configuration template file changes.
1816f743 341
3a28512c
JB
342#### automaticTransactionGenerator section
343
344The syntax is similar to the charging station configuration template 'AutomaticTransactionGenerator' section.
345
10211789
JB
346That section is overwritten on matching charging station configuration template file changes.
347
348#### automaticTransactionGeneratorStatuses section
349
350That section is not overwritten on matching charging station configuration template file changes.
351
352#### configurationKey section
353
354The syntax is similar to the charging station configuration template 'Configuration' section.
355
356That section is not overwritten on matching charging station configuration template file changes.
357
6f0ec20e
JB
358## Docker
359
360In the [docker](./docker) folder:
361
81ed2a48 362```shell
6f0ec20e
JB
363make
364```
365
673dceeb 366<!-- Or with the optional git submodules:
6f0ec20e 367
81ed2a48 368```shell
bfcad885 369make SUBMODULES_INIT=true
673dceeb 370``` -->
6f0ec20e
JB
371
372## OCPP-J commands supported
c94a349a
JB
373
374### Version 1.6
375
c56d42f1 376#### Core Profile
6f0ec20e 377
778f7924
JB
378- :white_check_mark: Authorize
379- :white_check_mark: BootNotification
380- :white_check_mark: ChangeAvailability
381- :white_check_mark: ChangeConfiguration
382- :white_check_mark: ClearCache
91a7d3ea 383- :white_check_mark: DataTransfer
778f7924
JB
384- :white_check_mark: GetConfiguration
385- :white_check_mark: Heartbeat
386- :white_check_mark: MeterValues
387- :white_check_mark: RemoteStartTransaction
388- :white_check_mark: RemoteStopTransaction
389- :white_check_mark: Reset
390- :white_check_mark: StartTransaction
391- :white_check_mark: StatusNotification
392- :white_check_mark: StopTransaction
393- :white_check_mark: UnlockConnector
6f0ec20e 394
c56d42f1 395#### Firmware Management Profile
6f0ec20e 396
b652b0c3 397- :white_check_mark: GetDiagnostics
d50343bd 398- :white_check_mark: DiagnosticsStatusNotification
c9a4f9ea
JB
399- :white_check_mark: FirmwareStatusNotification
400- :white_check_mark: UpdateFirmware
6f0ec20e 401
c56d42f1 402#### Local Auth List Management Profile
6f0ec20e 403
9e1b12e4
JB
404- :x: GetLocalListVersion
405- :x: SendLocalList
6f0ec20e 406
c56d42f1 407#### Reservation Profile
6f0ec20e 408
24578c31
JB
409- :white_check_mark: CancelReservation
410- :white_check_mark: ReserveNow
6f0ec20e 411
c56d42f1 412#### Smart Charging Profile
6f0ec20e 413
778f7924 414- :white_check_mark: ClearChargingProfile
e1d9a0f4 415- :white_check_mark: GetCompositeSchedule
778f7924 416- :white_check_mark: SetChargingProfile
6f0ec20e 417
c56d42f1 418#### Remote Trigger Profile
6f0ec20e 419
802cfa13 420- :white_check_mark: TriggerMessage
7dde0b73 421
d4371252
JB
422### Version 2.x.x
423
424#### Provisioning
425
426- :white_check_mark: BootNotification
427
bc950df1 428#### Authorization
d4371252
JB
429
430- :white_check_mark: ClearCache
431
432#### Availability
433
434- :white_check_mark: StatusNotification
435- :white_check_mark: Heartbeat
436
7e1dc878
JB
437## OCPP-J standard parameters supported
438
3a28512c 439All kind of OCPP parameters are supported in charging station configuration or charging station configuration template file. The list here mention the standard ones also handled automatically in the simulator.
7e1dc878
JB
440
441### Version 1.6
442
c56d42f1 443#### Core Profile
7e1dc878
JB
444
445- :white_check_mark: AuthorizeRemoteTxRequests (type: boolean) (units: -)
446- :x: ClockAlignedDataInterval (type: integer) (units: seconds)
291cb255 447- :white_check_mark: ConnectionTimeOut (type: integer) (units: seconds)
7e1dc878
JB
448- :x: GetConfigurationMaxKeys (type: integer) (units: -)
449- :white_check_mark: HeartbeatInterval (type: integer) (units: seconds)
450- :x: LocalAuthorizeOffline (type: boolean) (units: -)
451- :x: LocalPreAuthorize (type: boolean) (units: -)
452- :x: MeterValuesAlignedData (type: CSL) (units: -)
453- :white_check_mark: MeterValuesSampledData (type: CSL) (units: -)
454- :white_check_mark: MeterValueSampleInterval (type: integer) (units: seconds)
455- :white_check_mark: NumberOfConnectors (type: integer) (units: -)
456- :x: ResetRetries (type: integer) (units: times)
457- :white_check_mark: ConnectorPhaseRotation (type: CSL) (units: -)
458- :x: StopTransactionOnEVSideDisconnect (type: boolean) (units: -)
459- :x: StopTransactionOnInvalidId (type: boolean) (units: -)
460- :x: StopTxnAlignedData (type: CSL) (units: -)
461- :x: StopTxnSampledData (type: CSL) (units: -)
36f6a92e 462- :white_check_mark: SupportedFeatureProfiles (type: CSL) (units: -)
7e1dc878
JB
463- :x: TransactionMessageAttempts (type: integer) (units: times)
464- :x: TransactionMessageRetryInterval (type: integer) (units: seconds)
465- :x: UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -)
36f6a92e 466- :white_check_mark: WebSocketPingInterval (type: integer) (units: seconds)
7e1dc878 467
c56d42f1 468#### Firmware Management Profile
7e1dc878 469
e7aeea18 470- _none_
7e1dc878 471
c56d42f1 472#### Local Auth List Management Profile
7e1dc878 473
36f6a92e 474- :white_check_mark: LocalAuthListEnabled (type: boolean) (units: -)
7e1dc878
JB
475- :x: LocalAuthListMaxLength (type: integer) (units: -)
476- :x: SendLocalListMaxLength (type: integer) (units: -)
477
c56d42f1 478#### Reservation Profile
7e1dc878 479
66dd3447 480- :white_check_mark: ReserveConnectorZeroSupported (type: boolean) (units: -)
7e1dc878 481
c56d42f1 482#### Smart Charging Profile
7e1dc878
JB
483
484- :x: ChargeProfileMaxStackLevel (type: integer) (units: -)
485- :x: ChargingScheduleAllowedChargingRateUnit (type: CSL) (units: -)
486- :x: ChargingScheduleMaxPeriods (type: integer) (units: -)
487- :x: MaxChargingProfilesInstalled (type: integer) (units: -)
488
c56d42f1 489#### Remote Trigger Profile
7e1dc878 490
e7aeea18 491- _none_
7e1dc878 492
d4371252
JB
493### Version 2.x.x
494
32de5a57
LM
495## UI protocol
496
03ebf4c1 497Protocol to control the simulator via a Websocket or HTTP server.
32de5a57 498
4df14d3a
JB
499### HTTP Protocol
500
97c19696 501To learn how to use the HTTP protocol to pilot the simulator, an [Insomnia](https://insomnia.rest/) HTTP requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory.
4df14d3a 502
02cde3b7 503### Websocket Protocol
32de5a57 504
02cde3b7 505SRPC protocol over Websocket. PDU stands for 'Protocol Data Unit'.
32de5a57 506
03ebf4c1
JB
507- Request:
508 [`uuid`, `ProcedureName`, `PDU`]
509 `uuid`: String uniquely representing this request
510 `ProcedureName`: The procedure to run on the simulator
511 `PDU`: The parameters for said procedure
32de5a57 512
03ebf4c1
JB
513- Response:
514 [`uuid`, `PDU`]
515 `uuid`: String uniquely linking the response to the request
02cde3b7 516 `PDU`: Response parameters to requested procedure
32de5a57 517
97c19696
JB
518An [Insomnia](https://insomnia.rest/) WebSocket requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory.
519
d3140adc 520#### Version 0.0.1
4e3ff94d 521
02cde3b7 522Set the Websocket header _Sec-Websocket-Protocol_ to `ui0.0.1`.
4e3ff94d 523
d3140adc 524##### Procedures
32de5a57 525
d3140adc 526###### Start Simulator
5612b691 527
03ebf4c1
JB
528- Request:
529 `ProcedureName`: 'startSimulator'
530 `PDU`: {}
5612b691 531
03ebf4c1
JB
532- Response:
533 `PDU`: {
853ed24a 534 `status`: 'success' | 'failure'
03ebf4c1 535 }
5612b691 536
d3140adc 537###### Stop Simulator
5612b691 538
03ebf4c1
JB
539- Request:
540 `ProcedureName`: 'stopSimulator'
541 `PDU`: {}
5612b691 542
03ebf4c1
JB
543- Response:
544 `PDU`: {
853ed24a 545 `status`: 'success' | 'failure'
03ebf4c1 546 }
5612b691 547
d3140adc 548###### List Charging Stations
32de5a57 549
03ebf4c1
JB
550- Request:
551 `ProcedureName`: 'listChargingStations'
552 `PDU`: {}
32de5a57 553
03ebf4c1
JB
554- Response:
555 `PDU`: {
853ed24a 556 `status`: 'success' | 'failure',
02cde3b7 557 `chargingStations`: ChargingStationData[]
03ebf4c1 558 }
32de5a57 559
d3140adc 560###### Start Charging Station
80a3704c 561
03ebf4c1
JB
562- Request:
563 `ProcedureName`: 'startChargingStation'
564 `PDU`: {
03eee93b 565 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
03ebf4c1 566 }
80a3704c 567
03ebf4c1
JB
568- Response:
569 `PDU`: {
853ed24a
JB
570 `status`: 'success' | 'failure',
571 `hashIdsSucceeded`: charging station unique identifier strings array,
572 `hashIdsFailed`: charging station unique identifier strings array (optional)
03eee93b 573 `responsesFailed`: failed responses payload array (optional)
03ebf4c1 574 }
80a3704c 575
d3140adc 576###### Stop Charging Station
80a3704c 577
03ebf4c1
JB
578- Request:
579 `ProcedureName`: 'stopChargingStation'
580 `PDU`: {
853ed24a 581 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
03ebf4c1 582 }
80a3704c 583
03ebf4c1
JB
584- Response:
585 `PDU`: {
853ed24a
JB
586 `status`: 'success' | 'failure',
587 `hashIdsSucceeded`: charging station unique identifier strings array,
94abe068
JB
588 `hashIdsFailed`: charging station unique identifier strings array (optional),
589 `responsesFailed`: failed responses payload array (optional)
03ebf4c1 590 }
80a3704c 591
d3140adc 592###### Open Connection
e4df816e 593
03ebf4c1
JB
594- Request:
595 `ProcedureName`: 'openConnection'
596 `PDU`: {
853ed24a 597 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
03ebf4c1 598 }
e4df816e 599
03ebf4c1
JB
600- Response:
601 `PDU`: {
853ed24a
JB
602 `status`: 'success' | 'failure',
603 `hashIdsSucceeded`: charging station unique identifier strings array,
94abe068
JB
604 `hashIdsFailed`: charging station unique identifier strings array (optional),
605 `responsesFailed`: failed responses payload array (optional)
03ebf4c1 606 }
e4df816e 607
d3140adc 608###### Close Connection
e4df816e 609
03ebf4c1
JB
610- Request:
611 `ProcedureName`: 'closeConnection'
612 `PDU`: {
853ed24a 613 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
03ebf4c1
JB
614 }
615
616- Response:
617 `PDU`: {
853ed24a
JB
618 `status`: 'success' | 'failure',
619 `hashIdsSucceeded`: charging station unique identifier strings array,
94abe068
JB
620 `hashIdsFailed`: charging station unique identifier strings array (optional),
621 `responsesFailed`: failed responses payload array (optional)
853ed24a
JB
622 }
623
624###### Start Automatic Transaction Generator
625
626- Request:
627 `ProcedureName`: 'startAutomaticTransactionGenerator'
628 `PDU`: {
629 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
a38bc315 630 `connectorIds`: connector id integer array (optional, default: all connectors)
853ed24a
JB
631 }
632
633- Response:
634 `PDU`: {
635 `status`: 'success' | 'failure',
636 `hashIdsSucceeded`: charging station unique identifier strings array,
5566ca3e
JB
637 `hashIdsFailed`: charging station unique identifier strings array (optional),
638 `responsesFailed`: failed responses payload array (optional)
853ed24a
JB
639 }
640
641###### Stop Automatic Transaction Generator
642
643- Request:
644 `ProcedureName`: 'stopAutomaticTransactionGenerator'
645 `PDU`: {
646 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
a38bc315 647 `connectorIds`: connector id integer array (optional, default: all connectors)
853ed24a
JB
648 }
649
650- Response:
651 `PDU`: {
652 `status`: 'success' | 'failure',
653 `hashIdsSucceeded`: charging station unique identifier strings array,
5566ca3e
JB
654 `hashIdsFailed`: charging station unique identifier strings array (optional),
655 `responsesFailed`: failed responses payload array (optional)
03ebf4c1
JB
656 }
657
91a7d3ea 658###### OCPP commands trigger
a9ed42b2 659
82cbef8d
JB
660- Request:
661 `ProcedureName`: 'commandName' (the OCPP command name in camel case)
662 `PDU`: {
663 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
664 ...`commandPayload`
665 } (the OCPP command payload with some optional fields added to target the simulated charging stations)
10db00b2 666
82cbef8d
JB
667- Response:
668 `PDU`: {
669 `status`: 'success' | 'failure',
670 `hashIdsSucceeded`: charging station unique identifier strings array,
671 `hashIdsFailed`: charging station unique identifier strings array (optional),
672 `responsesFailed`: failed responses payload array (optional)
673 }
10db00b2 674
91a7d3ea 675Examples:
10db00b2 676
91a7d3ea 677- **Start Transaction**
a9ed42b2 678
91a7d3ea
JB
679 - Request:
680 `ProcedureName`: 'startTransaction'
681 `PDU`: {
682 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
683 `connectorId`: connector id integer,
684 `idTag`: RFID tag string
685 }
686
687 - Response:
688 `PDU`: {
689 `status`: 'success' | 'failure',
690 `hashIdsSucceeded`: charging station unique identifier strings array,
691 `hashIdsFailed`: charging station unique identifier strings array (optional),
692 `responsesFailed`: failed responses payload array (optional)
693 }
694
695- **Stop Transaction**
696
697 - Request:
698 `ProcedureName`: 'stopTransaction'
699 `PDU`: {
700 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
701 `transactionId`: transaction id integer
702 }
703
704 - Response:
705 `PDU`: {
706 `status`: 'success' | 'failure',
707 `hashIdsSucceeded`: charging station unique identifier strings array,
708 `hashIdsFailed`: charging station unique identifier strings array (optional),
709 `responsesFailed`: failed responses payload array (optional)
710 }
711
712- **Status Notification**
713
714 - Request:
82cbef8d 715 `ProcedureName`: 'statusNotification'
91a7d3ea
JB
716 `PDU`: {
717 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
718 `connectorId`: connector id integer,
719 `errorCode`: connector error code,
720 `status`: connector status
721 }
722
723 - Response:
724 `PDU`: {
725 `status`: 'success' | 'failure',
726 `hashIdsSucceeded`: charging station unique identifier strings array,
727 `hashIdsFailed`: charging station unique identifier strings array (optional),
728 `responsesFailed`: failed responses payload array (optional)
729 }
730
731- **Heartbeat**
732
733 - Request:
82cbef8d 734 `ProcedureName`: 'heartbeat'
91a7d3ea
JB
735 `PDU`: {
736 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
737 }
738
739 - Response:
740 `PDU`: {
741 `status`: 'success' | 'failure',
742 `hashIdsSucceeded`: charging station unique identifier strings array,
743 `hashIdsFailed`: charging station unique identifier strings array (optional),
744 `responsesFailed`: failed responses payload array (optional)
745 }
a9ed42b2 746
251fff5c 747## Support, Feedback, Contributing
7dde0b73 748
7f774a55 749This project is open to feature requests/suggestions, bug reports etc. via [GitHub issues](https://github.com/SAP/e-mobility-charging-stations-simulator/issues). Contribution and feedback are encouraged and always welcome. For more information about how to contribute, the project structure, as well as additional contribution information, see our [Contribution Guidelines](CONTRIBUTING.md).
7dde0b73 750
251fff5c
JB
751## Code of Conduct
752
753We as members, contributors, and leaders pledge to make participation in our community a harassment-free experience for everyone. By participating in this project, you agree to abide by its [Code of Conduct](CODE_OF_CONDUCT.md) at all times.
754
755## Licensing
756
a6609c86 757Copyright 2020-2023 SAP SE or an SAP affiliate company and e-mobility-charging-stations-simulator contributors. Please see our [LICENSE](LICENSE) for copyright and license information. Detailed information including third-party components and their licensing/copyright information is available [via the REUSE tool](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator).