feat: allow to override more template tunables at addChargingStations UI
[e-mobility-charging-stations-simulator.git] / README.md
CommitLineData
d6b76da3 1<!-- markdownlint-disable-file MD033 MD024 -->
9e0845f7 2
1ea2264a 3# [e-mobility charging stations simulator](https://github.com/sap/e-mobility-charging-stations-simulator)
7dde0b73 4
b0b6537f
JB
5[![GitHub Clones](https://img.shields.io/badge/dynamic/json?color=brightgreen&label=Clone&query=count&url=https://gist.githubusercontent.com/jerome-benoit/c7c669b881d5b27dc0b44a639504ff93/raw/clone.json&logo=github)](https://github.com/SAP/e-mobility-charging-stations-simulator/graphs/traffic)
6[![GitHub commit activity (main)](https://img.shields.io/github/commit-activity/m/SAP/e-mobility-charging-stations-simulator/main?color=brightgreen&logo=github)](https://github.com/SAP/e-mobility-charging-stations-simulator/graphs/commit-activity)
f1fded7b 7[![CI workflow](https://github.com/SAP/e-mobility-charging-stations-simulator/actions/workflows/ci.yml/badge.svg)](https://github.com/SAP/e-mobility-charging-stations-simulator/actions/workflows/ci.yml)
4d188eb9 8[![REUSE status](https://api.reuse.software/badge/github.com/SAP/e-mobility-charging-stations-simulator)](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator)
b157a1df 9[![Javascript Standard Style Guide](<https://badgen.net/static/code style/standard/green>)](https://standardjs.com)
0a3d08ef 10
7dde0b73
JB
11## Summary
12
a712de6f 13Simple [node.js](https://nodejs.org/) software to simulate and scale a set of charging stations based on the OCPP-J protocol as part of [SAP e-Mobility](https://www.sap.com/products/scm/e-mobility.html) solution.
7dde0b73 14
696ce53a
JB
15## Prerequisites
16
5845e83d 17Install the [node.js](https://nodejs.org/) current LTS or superior version runtime environment:
007ee642 18
696ce53a
JB
19### Windows
20
e7aeea18 21- [Chocolatey](https://chocolatey.org/):
696ce53a
JB
22
23```powershell
5845e83d 24choco install -y nodejs
696ce53a
JB
25```
26
27### MacOSX
28
e7aeea18 29- [Homebrew](https://brew.sh/):
696ce53a
JB
30
31```shell
5845e83d 32brew install node
696ce53a
JB
33```
34
d6b76da3 35### GNU/Linux
511780c3 36
eef659c1 37- [NodeSource](https://github.com/nodesource/distributions) Node.js Binary Distributions for all supported versions.
511780c3 38
007ee642
JB
39## Installation
40
1a662d29 41Enable corepack if not already done and install latest pnpm version:
5845e83d
JB
42
43```shell
44corepack enable
1a662d29 45corepack prepare pnpm@latest --activate
5845e83d
JB
46```
47
007ee642
JB
48In the repository root, run the following command:
49
50```shell
881f450c 51pnpm install
007ee642
JB
52```
53
54## Initial configuration
55
db70b600 56Copy the configuration template file [src/assets/config-template.json](src/assets/config-template.json) to [src/assets/config.json](src/assets/config.json).
e302df1d 57Copy the RFID tags template file [src/assets/idtags-template.json](src/assets/idtags-template.json) to [src/assets/idtags.json](src/assets/idtags.json).
db70b600 58
58b0ee76 59Tweak them to your needs by following the section [configuration files syntax](README.md#configuration-files-syntax): OCPP server supervision URL(s), charging station templates, etc.
007ee642
JB
60
61## Start
62
881f450c 63To start the program, run: `pnpm start`.
007ee642 64
4e3ff94d 65## Start Web UI
007ee642 66
ebbfbf1c 67See Web UI [README.md](ui/web/README.md) for more information.
b8cc885d 68
4d3821a2 69## Configuration files syntax
2c28fc83 70
e7aeea18 71All configuration files are in the JSON standard format.
2c28fc83 72
ff82dc5f 73**Configuration files locations**:
2c28fc83 74
170bec53 75- charging stations simulator configuration: [src/assets/config.json](src/assets/config.json);
1816f743 76- charging station configuration templates: [src/assets/station-templates](src/assets/station-templates);
1c51fd1d 77- charging station configurations: [dist/assets/configurations](dist/assets/configurations);
7f818162 78- charging station RFID tags lists: [src/assets](src/assets).
2c28fc83 79
1816f743
JB
80The charging stations simulator's configuration parameters must be within the `src/assets/config.json` file. A charging station simulator configuration template file is available at [src/assets/config-template.json](src/assets/config-template.json).
81
82All charging station configuration templates are in the directory [src/assets/station-templates](src/assets/station-templates).
83
3a28512c 84A list of RFID tags must be defined for the automatic transaction generator in a file with the default location and name: `src/assets/idtags.json`. A template file is available at [src/assets/idtags-template.json](src/assets/idtags-template.json).
1816f743
JB
85
86**Configuration files hierarchy and priority**:
87
1c51fd1d 881. charging station configuration: [dist/assets/configurations](dist/assets/configurations);
1816f743 892. charging station configuration template: [src/assets/station-templates](src/assets/station-templates);
170bec53 903. charging stations simulator configuration: [src/assets/config.json](src/assets/config.json).
511780c3 91
3a28512c 92The charging stations simulator has an automatic configuration files reload feature at change for:
511780c3 93
170bec53 94- charging stations simulator configuration;
1816f743 95- charging station configuration templates;
170bec53 96- charging station authorization RFID tags lists.
2c28fc83 97
3a28512c 98But the modifications to test have to be done to the files in the build target directory [dist/assets](dist/assets). Once the modifications are done, they have to be reported to the matching files in the build source directory [src/assets](src/assets) to ensure they will be taken into account at next build.
e7aeea18 99
170bec53 100### Charging stations simulator configuration
2c28fc83 101
b1d6e944 102**src/assets/config.json**:
2c28fc83 103
dda3305e
JB
104| Key | Value(s) | Default Value | Value type | Description |
105| -------------------------- | -------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ---------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
106| supervisionUrls | | [] | string \| string[] | string or strings array containing global connection URIs to OCPP-J servers |
107| supervisionUrlDistribution | round-robin/random/charging-station-affinity | charging-station-affinity | string | supervision urls distribution policy to simulated charging stations |
108| log | | {<br />"enabled": true,<br />"file": "logs/combined.log",<br />"errorFile": "logs/error.log",<br />"statisticsInterval": 60,<br />"level": "info",<br />"console": false,<br />"format": "simple",<br />"rotate": true<br />} | {<br />enabled?: boolean;<br />file?: string;<br />errorFile?: string;<br />statisticsInterval?: number;<br />level?: string;<br />console?: boolean;<br />format?: string;<br />rotate?: boolean;<br />maxFiles?: string \| number;<br />maxSize?: string \| number;<br />} | Log configuration section:<br />- _enabled_: enable logging<br />- _file_: log file relative path<br />- _errorFile_: error log file relative path<br />- _statisticsInterval_: seconds between charging stations statistics output in the logs<br />- _level_: emerg/alert/crit/error/warning/notice/info/debug [winston](https://github.com/winstonjs/winston) logging level</br >- _console_: output logs on the console<br />- _format_: [winston](https://github.com/winstonjs/winston) log format<br />- _rotate_: enable daily log files rotation<br />- _maxFiles_: maximum number of log files: https://github.com/winstonjs/winston-daily-rotate-file#options<br />- _maxSize_: maximum size of log files in bytes, or units of kb, mb, and gb: https://github.com/winstonjs/winston-daily-rotate-file#options |
f2816b1d 109| worker | | {<br />"processType": "workerSet",<br />"startDelay": 500,<br />"elementStartDelay": 0,<br />"elementsPerWorker": 'auto',<br />"poolMinSize": 4,<br />"poolMaxSize": 16<br />} | {<br />processType?: WorkerProcessType;<br />startDelay?: number;<br />elementStartDelay?: number;<br />elementsPerWorker?: number \| 'auto' \| 'all';<br />poolMinSize?: number;<br />poolMaxSize?: number;<br />resourceLimits?: ResourceLimits;<br />} | Worker configuration section:<br />- _processType_: worker threads process type (`workerSet`/`fixedPool`/`dynamicPool`)<br />- _startDelay_: milliseconds to wait at worker threads startup (only for `workerSet` worker threads process type)<br />- _elementStartDelay_: milliseconds to wait at charging station startup<br />- _elementsPerWorker_: number of charging stations per worker threads for the `workerSet` process type (`auto` means (number of stations) / (number of CPUs) \* 1.5 if (number of stations) > (number of CPUs), otherwise 1; `all` means a unique worker will run all charging stations)<br />- _poolMinSize_: worker threads pool minimum number of threads</br >- _poolMaxSize_: worker threads pool maximum number of threads<br />- _resourceLimits_: worker threads [resource limits](https://nodejs.org/api/worker_threads.html#new-workerfilename-options) object option |
dda3305e 110| uiServer | | {<br />"enabled": false,<br />"type": "ws",<br />"version": "1.1",<br />"options": {<br />"host": "localhost",<br />"port": 8080<br />}<br />} | {<br />enabled?: boolean;<br />type?: ApplicationProtocol;<br />version?: ApplicationProtocolVersion;<br />options?: ServerOptions;<br />authentication?: {<br />enabled: boolean;<br />type: AuthenticationType;<br />username?: string;<br />password?: string;<br />}<br />} | UI server configuration section:<br />- _enabled_: enable UI server<br />- _type_: 'http' or 'ws'<br />- _version_: HTTP version '1.1' or '2.0'<br />- _options_: node.js net module [listen options](https://nodejs.org/api/net.html#serverlistenoptions-callback)<br />- _authentication_: authentication type configuration section |
a66bbcfe 111| performanceStorage | | {<br />"enabled": true,<br />"type": "none",<br />} | {<br />enabled?: boolean;<br />type?: string;<br />uri?: string;<br />} | Performance storage configuration section:<br />- _enabled_: enable performance storage<br />- _type_: 'jsonfile', 'mongodb' or 'none'<br />- _uri_: storage URI |
dda3305e 112| stationTemplateUrls | | {}[] | {<br />file: string;<br />numberOfStations: number;<br />}[] | array of charging station configuration templates URIs configuration section (charging station configuration template file name and number of stations) |
e7aeea18 113
d6b76da3 114#### Worker process model
a6b3c6c3
JB
115
116- **workerSet**:
1d8f226b 117 Worker set executing each a fixed number (elementsPerWorker) of simulated charging stations from the total
a6b3c6c3 118
1d8f226b
JB
119- **fixedPool**:
120 Fixedly sized worker pool executing a fixed total number of simulated charging stations
a6b3c6c3 121
56e2e1ab 122- **dynamicPool** (experimental):
1d8f226b 123 Dynamically sized worker pool executing a fixed total number of simulated charging stations
a6b3c6c3 124
1816f743
JB
125### Charging station configuration template
126
afccb423 127**src/assets/station-templates/\<name\>.json**:
1816f743 128
dda3305e
JB
129| Key | Value(s) | Default Value | Value type | Description |
130| ---------------------------------------------------- | ------------- | ---------------------------------------------------------------------------------------------------------------------------------- | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------- | ------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------ |
131| supervisionUrls | | [] | string \| string[] | string or strings array containing connection URIs to OCPP-J servers |
132| supervisionUser | | undefined | string | basic HTTP authentication user to OCPP-J server |
133| supervisionPassword | | undefined | string | basic HTTP authentication password to OCPP-J server |
244c1396 134| supervisionUrlOcppConfiguration | true/false | false | boolean | enable supervision URL configuration via a vendor OCPP parameter key |
dda3305e 135| supervisionUrlOcppKey | | 'ConnectionUrl' | string | the vendor string that will be used as a vendor OCPP parameter key to set the supervision URL |
244c1396 136| autoStart | true/false | true | boolean | enable automatic start of added charging station from template |
dda3305e
JB
137| ocppVersion | 1.6/2.0/2.0.1 | 1.6 | string | OCPP version |
138| ocppProtocol | json | json | string | OCPP protocol |
244c1396 139| ocppStrictCompliance | true/false | true | boolean | enable strict adherence to the OCPP version and protocol specifications with OCPP commands PDU validation against [OCA](https://www.openchargealliance.org/) JSON schemas |
dda3305e
JB
140| ocppPersistentConfiguration | true/false | true | boolean | enable persistent OCPP parameters storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
141| stationInfoPersistentConfiguration | true/false | true | boolean | enable persistent station information and specifications storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
142| automaticTransactionGeneratorPersistentConfiguration | true/false | true | boolean | enable persistent automatic transaction generator configuration storage by charging stations 'hashId'. The persistency is ensured by the charging stations configuration files in [dist/assets/configurations](dist/assets/configurations) |
143| wsOptions | | {} | ClientOptions & ClientRequestArgs | [ws](https://github.com/websockets/ws) and node.js [http](https://nodejs.org/api/http.html) clients options intersection |
144| idTagsFile | | undefined | string | RFID tags list file relative to [src/assets](src/assets) path |
145| baseName | | undefined | string | base name to build charging stations id |
146| nameSuffix | | undefined | string | name suffix to build charging stations id |
147| fixedName | true/false | false | boolean | use the 'baseName' as the charging stations unique name |
148| chargePointModel | | undefined | string | charging stations model |
149| chargePointVendor | | undefined | string | charging stations vendor |
150| chargePointSerialNumberPrefix | | undefined | string | charge point serial number prefix |
151| chargeBoxSerialNumberPrefix | | undefined | string | charge box serial number prefix (deprecated since OCPP 1.6) |
152| firmwareVersionPattern | | Semantic versioning regular expression: https://semver.org/#is-there-a-suggested-regular-expression-regex-to-check-a-semver-string | string | charging stations firmware version pattern |
153| firmwareVersion | | undefined | string | charging stations firmware version |
154| power | | | float \| float[] | charging stations maximum power value(s) |
155| powerSharedByConnectors | true/false | false | boolean | charging stations power shared by its connectors |
156| powerUnit | W/kW | W | string | charging stations power unit |
157| currentOutType | AC/DC | AC | string | charging stations current out type |
158| voltageOut | | AC:230/DC:400 | integer | charging stations voltage out |
159| numberOfPhases | 0/1/3 | AC:3/DC:0 | integer | charging stations number of phase(s) |
160| numberOfConnectors | | | integer \| integer[] | charging stations number of connector(s) |
161| useConnectorId0 | true/false | true | boolean | use connector id 0 definition from the charging station configuration template |
162| randomConnectors | true/false | false | boolean | randomize runtime connector id affectation from the connector id definition in charging station configuration template |
163| resetTime | | 60 | integer | seconds to wait before the charging stations come back at reset |
164| autoRegister | true/false | false | boolean | set charging stations as registered at boot notification for testing purpose |
165| autoReconnectMaxRetries | | -1 (unlimited) | integer | connection retries to the OCPP-J server |
166| reconnectExponentialDelay | true/false | false | boolean | connection delay retry to the OCPP-J server |
167| registrationMaxRetries | | -1 (unlimited) | integer | charging stations boot notification retries |
168| amperageLimitationOcppKey | | undefined | string | charging stations OCPP parameter key used to set the amperage limit, per phase for each connector on AC and global for DC |
169| amperageLimitationUnit | A/cA/dA/mA | A | string | charging stations amperage limit unit |
170| enableStatistics | true/false | false | boolean | enable charging stations statistics |
171| remoteAuthorization | true/false | true | boolean | enable RFID tags remote authorization |
172| beginEndMeterValues | true/false | false | boolean | enable Transaction.{Begin,End} MeterValues |
173| outOfOrderEndMeterValues | true/false | false | boolean | send Transaction.End MeterValues out of order. Need to relax OCPP specifications strict compliance ('ocppStrictCompliance' parameter) |
174| meteringPerTransaction | true/false | true | boolean | enable metering history on a per transaction basis |
175| transactionDataMeterValues | true/false | false | boolean | enable transaction data MeterValues at stop transaction |
176| stopTransactionsOnStopped | true/false | true | boolean | enable stop transactions on charging station stop |
177| mainVoltageMeterValues | true/false | true | boolean | include charging stations main voltage MeterValues on three phased charging stations |
178| phaseLineToLineVoltageMeterValues | true/false | false | boolean | include charging stations line to line voltage MeterValues on three phased charging stations |
179| customValueLimitationMeterValues | true/false | true | boolean | enable limitation on custom fluctuated value in MeterValues |
180| firmwareUpgrade | | {<br />"versionUpgrade": {<br />"step": 1<br />},<br />"reset": true<br />} | {<br />versionUpgrade?: {<br />patternGroup?: number;<br />step?: number;<br />};<br />reset?: boolean;<br />failureStatus?: 'DownloadFailed' \| 'InstallationFailed';<br />} | Configuration section for simulating firmware upgrade support. |
181| commandsSupport | | {<br />"incomingCommands": {},<br />"outgoingCommands": {}<br />} | {<br /> incomingCommands: Record<IncomingRequestCommand, boolean>;<br />outgoingCommands?: Record<RequestCommand, boolean>;<br />} | Configuration section for OCPP commands support. Empty section or subsections means all implemented OCPP commands are supported |
182| messageTriggerSupport | | {} | Record<MessageTrigger, boolean> | Configuration section for OCPP commands trigger support. Empty section means all implemented OCPP trigger commands are supported |
183| Configuration | | | ChargingStationOcppConfiguration | charging stations OCPP parameters configuration section |
184| AutomaticTransactionGenerator | | | AutomaticTransactionGeneratorConfiguration | charging stations ATG configuration section |
185| Connectors | | | Record<string, ConnectorStatus> | charging stations connectors configuration section |
186| Evses | | | Record<string, EvseTemplate> | charging stations EVSEs configuration section |
c94a349a 187
3e1dfe42 188#### Configuration section syntax example
c94a349a
JB
189
190```json
0302da79 191 "Configuration": {
c94a349a
JB
192 "configurationKey": [
193 ...
194 {
195 "key": "StandardKey",
196 "readonly": false,
197 "value": "StandardValue",
198 "visible": true,
199 "reboot": false
200 },
201 ...
202 {
203 "key": "VendorKey",
204 "readonly": false,
205 "value": "VendorValue",
206 "visible": false,
207 "reboot": true
208 },
209 ...
210 ]
211 }
212```
213
3e1dfe42 214#### AutomaticTransactionGenerator section syntax example
c94a349a 215
20f09970 216##### Type definition:
c72f6634
JB
217
218```ts
219type AutomaticTransactionGeneratorConfiguration = {
66a7748d
JB
220 enable: boolean
221 minDuration: number
222 maxDuration: number
223 minDelayBetweenTwoTransactions: number
224 maxDelayBetweenTwoTransactions: number
225 probabilityOfStart: number
226 stopAfterHours: number
46a830d2 227 stopAbsoluteDuration: boolean
66a7748d
JB
228 requireAuthorize?: boolean
229 idTagDistribution?: 'random' | 'round-robin' | 'connector-affinity'
230}
c72f6634
JB
231```
232
20f09970 233##### Example:
c72f6634 234
c94a349a 235```json
0302da79 236 "AutomaticTransactionGenerator": {
c94a349a
JB
237 "enable": false,
238 "minDuration": 60,
239 "maxDuration": 80,
240 "minDelayBetweenTwoTransactions": 15,
241 "maxDelayBetweenTwoTransactions": 30,
242 "probabilityOfStart": 1,
243 "stopAfterHours": 0.3,
c72f6634
JB
244 "requireAuthorize": true,
245 "idTagDistribution": "random"
c94a349a
JB
246 }
247```
e7aeea18 248
3e1dfe42 249#### Connectors section syntax example
c94a349a
JB
250
251```json
0302da79 252 "Connectors": {
c94a349a
JB
253 "0": {},
254 "1": {
255 "bootStatus": "Available",
256 "MeterValues": [
9bd87386
JB
257 ...
258 {
259 "unit": "W",
260 "measurand": "Power.Active.Import",
261 "phase": "L1-N",
262 "value": "5000",
263 "fluctuationPercent": "10"
264 },
c94a349a
JB
265 ...
266 {
267 "unit": "A",
860ef183
JB
268 "measurand": "Current.Import",
269 "minimum": "0.5"
c94a349a
JB
270 },
271 ...
272 {
273 "unit": "Wh"
274 },
275 ...
276 ]
277 }
278 },
279```
280
3e1dfe42
JB
281#### Evses section syntax example
282
283```json
284 "Evses": {
285 "0": {
286 "Connectors": {
287 "0": {}
288 }
289 },
290 "1": {
291 "Connectors": {
292 "1": {
293 "bootStatus": "Available",
294 "MeterValues": [
295 ...
296 {
297 "unit": "W",
298 "measurand": "Power.Active.Import",
299 "phase": "L1-N",
300 "value": "5000",
301 "fluctuationPercent": "10"
302 },
303 ...
304 {
305 "unit": "A",
306 "measurand": "Current.Import",
307 "minimum": "0.5"
308 },
309 ...
310 {
311 "unit": "Wh"
312 },
313 ...
314 ]
315 }
316 }
317 }
318 },
319```
320
1816f743
JB
321### Charging station configuration
322
1c51fd1d 323**dist/assets/configurations/\<hashId\>.json**:
1816f743 324
a9ec2018 325The charging station configuration file is automatically generated at startup from the charging station configuration template file and is persistent.
1816f743
JB
326
327The charging station configuration file content can be regenerated partially on matching charging station configuration template file changes. The charging station serial number is kept unchanged.
328
09810639 329#### stationInfo section (optional)
1816f743
JB
330
331The syntax is similar to charging station configuration template with some added fields like the charging station id (name) and the 'Configuration' section removed.
332
10211789 333That section is overwritten on matching charging station configuration template file changes.
1816f743 334
10211789
JB
335#### connectorsStatus section
336
337The syntax is similar to charging station configuration template 'Connectors' section with some added fields.
338
339That section is overwritten on matching charging station configuration template file changes.
1816f743 340
0aa874ce
JB
341#### evsesStatus section
342
343The syntax is similar to charging station configuration template 'Evses' section with some added fields.
344
345That section is overwritten on matching charging station configuration template file changes.
346
09810639 347#### automaticTransactionGenerator section (optional)
3a28512c
JB
348
349The syntax is similar to the charging station configuration template 'AutomaticTransactionGenerator' section.
350
10211789
JB
351That section is overwritten on matching charging station configuration template file changes.
352
353#### automaticTransactionGeneratorStatuses section
354
355That section is not overwritten on matching charging station configuration template file changes.
356
09810639 357#### configurationKey section (optional)
10211789
JB
358
359The syntax is similar to the charging station configuration template 'Configuration' section.
360
361That section is not overwritten on matching charging station configuration template file changes.
362
6f0ec20e
JB
363## Docker
364
365In the [docker](./docker) folder:
366
81ed2a48 367```shell
6f0ec20e
JB
368make
369```
370
673dceeb 371<!-- Or with the optional git submodules:
6f0ec20e 372
81ed2a48 373```shell
bfcad885 374make SUBMODULES_INIT=true
673dceeb 375``` -->
6f0ec20e
JB
376
377## OCPP-J commands supported
c94a349a
JB
378
379### Version 1.6
380
c56d42f1 381#### Core Profile
6f0ec20e 382
778f7924
JB
383- :white_check_mark: Authorize
384- :white_check_mark: BootNotification
385- :white_check_mark: ChangeAvailability
386- :white_check_mark: ChangeConfiguration
387- :white_check_mark: ClearCache
91a7d3ea 388- :white_check_mark: DataTransfer
778f7924
JB
389- :white_check_mark: GetConfiguration
390- :white_check_mark: Heartbeat
391- :white_check_mark: MeterValues
392- :white_check_mark: RemoteStartTransaction
393- :white_check_mark: RemoteStopTransaction
394- :white_check_mark: Reset
395- :white_check_mark: StartTransaction
396- :white_check_mark: StatusNotification
397- :white_check_mark: StopTransaction
398- :white_check_mark: UnlockConnector
6f0ec20e 399
c56d42f1 400#### Firmware Management Profile
6f0ec20e 401
b652b0c3 402- :white_check_mark: GetDiagnostics
d50343bd 403- :white_check_mark: DiagnosticsStatusNotification
c9a4f9ea
JB
404- :white_check_mark: FirmwareStatusNotification
405- :white_check_mark: UpdateFirmware
6f0ec20e 406
c56d42f1 407#### Local Auth List Management Profile
6f0ec20e 408
9e1b12e4
JB
409- :x: GetLocalListVersion
410- :x: SendLocalList
6f0ec20e 411
c56d42f1 412#### Reservation Profile
6f0ec20e 413
24578c31
JB
414- :white_check_mark: CancelReservation
415- :white_check_mark: ReserveNow
6f0ec20e 416
c56d42f1 417#### Smart Charging Profile
6f0ec20e 418
778f7924 419- :white_check_mark: ClearChargingProfile
e1d9a0f4 420- :white_check_mark: GetCompositeSchedule
778f7924 421- :white_check_mark: SetChargingProfile
6f0ec20e 422
c56d42f1 423#### Remote Trigger Profile
6f0ec20e 424
802cfa13 425- :white_check_mark: TriggerMessage
7dde0b73 426
d4371252
JB
427### Version 2.x.x
428
429#### Provisioning
430
431- :white_check_mark: BootNotification
432
bc950df1 433#### Authorization
d4371252
JB
434
435- :white_check_mark: ClearCache
436
437#### Availability
438
439- :white_check_mark: StatusNotification
440- :white_check_mark: Heartbeat
441
7e1dc878
JB
442## OCPP-J standard parameters supported
443
3a28512c 444All kind of OCPP parameters are supported in charging station configuration or charging station configuration template file. The list here mention the standard ones also handled automatically in the simulator.
7e1dc878
JB
445
446### Version 1.6
447
c56d42f1 448#### Core Profile
7e1dc878
JB
449
450- :white_check_mark: AuthorizeRemoteTxRequests (type: boolean) (units: -)
451- :x: ClockAlignedDataInterval (type: integer) (units: seconds)
291cb255 452- :white_check_mark: ConnectionTimeOut (type: integer) (units: seconds)
7e1dc878
JB
453- :x: GetConfigurationMaxKeys (type: integer) (units: -)
454- :white_check_mark: HeartbeatInterval (type: integer) (units: seconds)
455- :x: LocalAuthorizeOffline (type: boolean) (units: -)
456- :x: LocalPreAuthorize (type: boolean) (units: -)
457- :x: MeterValuesAlignedData (type: CSL) (units: -)
458- :white_check_mark: MeterValuesSampledData (type: CSL) (units: -)
459- :white_check_mark: MeterValueSampleInterval (type: integer) (units: seconds)
460- :white_check_mark: NumberOfConnectors (type: integer) (units: -)
461- :x: ResetRetries (type: integer) (units: times)
462- :white_check_mark: ConnectorPhaseRotation (type: CSL) (units: -)
463- :x: StopTransactionOnEVSideDisconnect (type: boolean) (units: -)
464- :x: StopTransactionOnInvalidId (type: boolean) (units: -)
465- :x: StopTxnAlignedData (type: CSL) (units: -)
466- :x: StopTxnSampledData (type: CSL) (units: -)
36f6a92e 467- :white_check_mark: SupportedFeatureProfiles (type: CSL) (units: -)
7e1dc878
JB
468- :x: TransactionMessageAttempts (type: integer) (units: times)
469- :x: TransactionMessageRetryInterval (type: integer) (units: seconds)
470- :x: UnlockConnectorOnEVSideDisconnect (type: boolean) (units: -)
36f6a92e 471- :white_check_mark: WebSocketPingInterval (type: integer) (units: seconds)
7e1dc878 472
c56d42f1 473#### Firmware Management Profile
7e1dc878 474
e7aeea18 475- _none_
7e1dc878 476
c56d42f1 477#### Local Auth List Management Profile
7e1dc878 478
36f6a92e 479- :white_check_mark: LocalAuthListEnabled (type: boolean) (units: -)
7e1dc878
JB
480- :x: LocalAuthListMaxLength (type: integer) (units: -)
481- :x: SendLocalListMaxLength (type: integer) (units: -)
482
c56d42f1 483#### Reservation Profile
7e1dc878 484
66dd3447 485- :white_check_mark: ReserveConnectorZeroSupported (type: boolean) (units: -)
7e1dc878 486
c56d42f1 487#### Smart Charging Profile
7e1dc878
JB
488
489- :x: ChargeProfileMaxStackLevel (type: integer) (units: -)
490- :x: ChargingScheduleAllowedChargingRateUnit (type: CSL) (units: -)
491- :x: ChargingScheduleMaxPeriods (type: integer) (units: -)
492- :x: MaxChargingProfilesInstalled (type: integer) (units: -)
493
c56d42f1 494#### Remote Trigger Profile
7e1dc878 495
e7aeea18 496- _none_
7e1dc878 497
d4371252
JB
498### Version 2.x.x
499
32de5a57
LM
500## UI protocol
501
6ca7a41d 502Protocol to control the simulator via a Websocket or HTTP server:
32de5a57 503
5d8bbc63
JB
504```mermaid
505sequenceDiagram
506Client->>UI Server: request
507UI Server->>Client: response
4c4f320e 508Note over UI Server,Client: Transport protocol: HTTP, Websocket
5d8bbc63
JB
509```
510
02cde3b7 511### Websocket Protocol
32de5a57 512
02cde3b7 513SRPC protocol over Websocket. PDU stands for 'Protocol Data Unit'.
32de5a57 514
03ebf4c1
JB
515- Request:
516 [`uuid`, `ProcedureName`, `PDU`]
517 `uuid`: String uniquely representing this request
518 `ProcedureName`: The procedure to run on the simulator
519 `PDU`: The parameters for said procedure
32de5a57 520
03ebf4c1
JB
521- Response:
522 [`uuid`, `PDU`]
523 `uuid`: String uniquely linking the response to the request
02cde3b7 524 `PDU`: Response parameters to requested procedure
32de5a57 525
c03dea88 526To learn how to use the Websocket protocol to pilot the simulator, an [Insomnia](https://insomnia.rest/) Websocket requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory.
97c19696 527
d3140adc 528#### Version 0.0.1
4e3ff94d 529
02cde3b7 530Set the Websocket header _Sec-Websocket-Protocol_ to `ui0.0.1`.
4e3ff94d 531
d3140adc 532##### Procedures
32de5a57 533
d3140adc 534###### Start Simulator
5612b691 535
03ebf4c1
JB
536- Request:
537 `ProcedureName`: 'startSimulator'
538 `PDU`: {}
5612b691 539
03ebf4c1
JB
540- Response:
541 `PDU`: {
6ca7a41d 542 `status`: 'success' | 'failure'
03ebf4c1 543 }
5612b691 544
d3140adc 545###### Stop Simulator
5612b691 546
03ebf4c1
JB
547- Request:
548 `ProcedureName`: 'stopSimulator'
549 `PDU`: {}
5612b691 550
03ebf4c1
JB
551- Response:
552 `PDU`: {
6ca7a41d
JB
553 `status`: 'success' | 'failure'
554 }
555
556###### List Charging Station Templates
557
558- Request:
559 `ProcedureName`: 'listTemplates'
560 `PDU`: {}
561
562- Response:
563 `PDU`: {
564 `status`: 'success' | 'failure',
565 `templates`: string[]
566 }
567
568###### Add Charging Stations
569
570- Request:
571 `ProcedureName`: 'addChargingStations'
572 `PDU`: {
573 `template`: string,
95c7658e
JB
574 `numberOfStations`: number,
575 `options?`: {
52c58949
JB
576 `autoStart?`: boolean,
577 `autoRegister?`: boolean,
578 `persistentConfiguration?`: boolean
95c7658e 579 }
6ca7a41d
JB
580 }
581
582- Response:
583 `PDU`: {
584 `status`: 'success' | 'failure'
03ebf4c1 585 }
5612b691 586
1e534dab
JB
587###### Set Charging Station Supervision Url
588
589- Request:
590 `ProcedureName`: 'setSupervisionUrl'
591 `PDU`: {
592 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
a66bbcfe 593 `url`: string
1e534dab
JB
594 }
595
596- Response:
597 `PDU`: {
598 `status`: 'success' | 'failure',
599 `hashIdsSucceeded`: charging station unique identifier strings array,
600 `hashIdsFailed`: charging station unique identifier strings array (optional),
601 `responsesFailed`: failed responses payload array (optional)
602 }
603
a66bbcfe
JB
604###### Performance Statistics
605
606- Request:
607 `ProcedureName`: 'performanceStatistics'
608 `PDU`: {}
609
610- Response:
611 `PDU`: {
612 `status`: 'success' | 'failure'
613 `performanceStatistics`: Statistics[]
614 }
615
d3140adc 616###### List Charging Stations
32de5a57 617
03ebf4c1
JB
618- Request:
619 `ProcedureName`: 'listChargingStations'
620 `PDU`: {}
32de5a57 621
03ebf4c1
JB
622- Response:
623 `PDU`: {
6ca7a41d
JB
624 `status`: 'success' | 'failure',
625 `chargingStations`: ChargingStationData[]
03ebf4c1 626 }
32de5a57 627
d3140adc 628###### Start Charging Station
80a3704c 629
03ebf4c1
JB
630- Request:
631 `ProcedureName`: 'startChargingStation'
632 `PDU`: {
6ca7a41d 633 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
03ebf4c1 634 }
80a3704c 635
03ebf4c1
JB
636- Response:
637 `PDU`: {
6ca7a41d
JB
638 `status`: 'success' | 'failure',
639 `hashIdsSucceeded`: charging station unique identifier strings array,
640 `hashIdsFailed`: charging station unique identifier strings array (optional),
641 `responsesFailed`: failed responses payload array (optional)
03ebf4c1 642 }
80a3704c 643
d3140adc 644###### Stop Charging Station
80a3704c 645
03ebf4c1
JB
646- Request:
647 `ProcedureName`: 'stopChargingStation'
648 `PDU`: {
6ca7a41d 649 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
03ebf4c1 650 }
80a3704c 651
03ebf4c1
JB
652- Response:
653 `PDU`: {
6ca7a41d
JB
654 `status`: 'success' | 'failure',
655 `hashIdsSucceeded`: charging station unique identifier strings array,
656 `hashIdsFailed`: charging station unique identifier strings array (optional),
657 `responsesFailed`: failed responses payload array (optional)
03ebf4c1 658 }
80a3704c 659
d3140adc 660###### Open Connection
e4df816e 661
03ebf4c1
JB
662- Request:
663 `ProcedureName`: 'openConnection'
664 `PDU`: {
6ca7a41d 665 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
03ebf4c1 666 }
e4df816e 667
03ebf4c1
JB
668- Response:
669 `PDU`: {
6ca7a41d
JB
670 `status`: 'success' | 'failure',
671 `hashIdsSucceeded`: charging station unique identifier strings array,
672 `hashIdsFailed`: charging station unique identifier strings array (optional),
673 `responsesFailed`: failed responses payload array (optional)
03ebf4c1 674 }
e4df816e 675
d3140adc 676###### Close Connection
e4df816e 677
03ebf4c1
JB
678- Request:
679 `ProcedureName`: 'closeConnection'
680 `PDU`: {
6ca7a41d 681 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations)
03ebf4c1
JB
682 }
683
684- Response:
685 `PDU`: {
6ca7a41d
JB
686 `status`: 'success' | 'failure',
687 `hashIdsSucceeded`: charging station unique identifier strings array,
688 `hashIdsFailed`: charging station unique identifier strings array (optional),
689 `responsesFailed`: failed responses payload array (optional)
853ed24a
JB
690 }
691
692###### Start Automatic Transaction Generator
693
694- Request:
695 `ProcedureName`: 'startAutomaticTransactionGenerator'
696 `PDU`: {
6ca7a41d
JB
697 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
698 `connectorIds`: connector id integer array (optional, default: all connectors)
853ed24a
JB
699 }
700
701- Response:
702 `PDU`: {
6ca7a41d
JB
703 `status`: 'success' | 'failure',
704 `hashIdsSucceeded`: charging station unique identifier strings array,
705 `hashIdsFailed`: charging station unique identifier strings array (optional),
706 `responsesFailed`: failed responses payload array (optional)
853ed24a
JB
707 }
708
709###### Stop Automatic Transaction Generator
710
711- Request:
712 `ProcedureName`: 'stopAutomaticTransactionGenerator'
713 `PDU`: {
6ca7a41d
JB
714 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
715 `connectorIds`: connector id integer array (optional, default: all connectors)
853ed24a
JB
716 }
717
718- Response:
719 `PDU`: {
6ca7a41d
JB
720 `status`: 'success' | 'failure',
721 `hashIdsSucceeded`: charging station unique identifier strings array,
722 `hashIdsFailed`: charging station unique identifier strings array (optional),
723 `responsesFailed`: failed responses payload array (optional)
03ebf4c1
JB
724 }
725
91a7d3ea 726###### OCPP commands trigger
a9ed42b2 727
82cbef8d
JB
728- Request:
729 `ProcedureName`: 'commandName' (the OCPP command name in camel case)
730 `PDU`: {
731 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
732 ...`commandPayload`
1e534dab 733 } (the OCPP command payload with some optional fields added to target the simulated charging stations)
10db00b2 734
82cbef8d 735- Response:
7f9d5299 736 `PDU`: {
82cbef8d
JB
737 `status`: 'success' | 'failure',
738 `hashIdsSucceeded`: charging station unique identifier strings array,
739 `hashIdsFailed`: charging station unique identifier strings array (optional),
740 `responsesFailed`: failed responses payload array (optional)
1e534dab 741 }
10db00b2 742
91a7d3ea 743Examples:
10db00b2 744
91a7d3ea 745- **Start Transaction**
a9ed42b2 746
91a7d3ea
JB
747 - Request:
748 `ProcedureName`: 'startTransaction'
749 `PDU`: {
6ca7a41d
JB
750 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
751 `connectorId`: connector id integer,
752 `idTag`: RFID tag string
91a7d3ea
JB
753 }
754
755 - Response:
756 `PDU`: {
6ca7a41d
JB
757 `status`: 'success' | 'failure',
758 `hashIdsSucceeded`: charging station unique identifier strings array,
759 `hashIdsFailed`: charging station unique identifier strings array (optional),
760 `responsesFailed`: failed responses payload array (optional)
91a7d3ea
JB
761 }
762
763- **Stop Transaction**
764
765 - Request:
766 `ProcedureName`: 'stopTransaction'
767 `PDU`: {
6ca7a41d
JB
768 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
769 `transactionId`: transaction id integer
91a7d3ea
JB
770 }
771
772 - Response:
773 `PDU`: {
1e534dab 774 `status`: 'success' | 'failure',
6ca7a41d
JB
775 `hashIdsSucceeded`: charging station unique identifier strings array,
776 `hashIdsFailed`: charging station unique identifier strings array (optional),
777 `responsesFailed`: failed responses payload array (optional)
91a7d3ea
JB
778 }
779
780- **Status Notification**
781
782 - Request:
82cbef8d 783 `ProcedureName`: 'statusNotification'
91a7d3ea 784 `PDU`: {
6ca7a41d
JB
785 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
786 `connectorId`: connector id integer,
787 `errorCode`: connector error code,
788 `status`: connector status
91a7d3ea
JB
789 }
790
791 - Response:
792 `PDU`: {
6ca7a41d
JB
793 `status`: 'success' | 'failure',
794 `hashIdsSucceeded`: charging station unique identifier strings array,
795 `hashIdsFailed`: charging station unique identifier strings array (optional),
796 `responsesFailed`: failed responses payload array (optional)
91a7d3ea
JB
797 }
798
799- **Heartbeat**
800
801 - Request:
82cbef8d 802 `ProcedureName`: 'heartbeat'
91a7d3ea 803 `PDU`: {
6ca7a41d 804 `hashIds`: charging station unique identifier strings array (optional, default: all charging stations),
91a7d3ea
JB
805 }
806
807 - Response:
808 `PDU`: {
6ca7a41d
JB
809 `status`: 'success' | 'failure',
810 `hashIdsSucceeded`: charging station unique identifier strings array,
811 `hashIdsFailed`: charging station unique identifier strings array (optional),
812 `responsesFailed`: failed responses payload array (optional)
91a7d3ea 813 }
a9ed42b2 814
6ca7a41d
JB
815### HTTP Protocol
816
817To learn how to use the HTTP protocol to pilot the simulator, an [Insomnia](https://insomnia.rest/) HTTP requests collection is available in [src/assets/ui-protocol](./src/assets/ui-protocol) directory.
818
251fff5c 819## Support, Feedback, Contributing
7dde0b73 820
7f774a55 821This project is open to feature requests/suggestions, bug reports etc. via [GitHub issues](https://github.com/SAP/e-mobility-charging-stations-simulator/issues). Contribution and feedback are encouraged and always welcome. For more information about how to contribute, the project structure, as well as additional contribution information, see our [Contribution Guidelines](CONTRIBUTING.md).
7dde0b73 822
251fff5c
JB
823## Code of Conduct
824
825We as members, contributors, and leaders pledge to make participation in our community a harassment-free experience for everyone. By participating in this project, you agree to abide by its [Code of Conduct](CODE_OF_CONDUCT.md) at all times.
826
827## Licensing
828
a19b897d 829Copyright 2020-2024 SAP SE or an SAP affiliate company and e-mobility-charging-stations-simulator contributors. Please see our [LICENSE](LICENSE) for copyright and license information. Detailed information including third-party components and their licensing/copyright information is available [via the REUSE tool](https://api.reuse.software/info/github.com/SAP/e-mobility-charging-stations-simulator).